• 제목/요약/키워드: Cooling Outlet

검색결과 213건 처리시간 0.028초

Fluctuation Rates of Phytoplankton Assemblages by Passage through Power Plant Cooling System

  • Kang, Yeon-Shik;Lim, Ju-Hwan;Jeong, Yeon-Tae;Jeon, In-Sung
    • 환경생물
    • /
    • 제30권3호
    • /
    • pp.173-184
    • /
    • 2012
  • In order to investigate the fluctuation rates [FR] of phytoplankton after passage through a cooling system, the standing crops, chlorophyll a concentrations and carbon assimilation number of phytoplankton were surveyed at intake and outlet at Wolsong nuclear power plant [NPP] from July 2006 to June 2008. As a result, the total mean standing crops of phytoplankton were $1.0{\times}10^6\;cells\;L^{-1}$ and $7.3{\times}10^5\;cells\;L^{-1}$ at intake and outlet, respectively. The FR of phytoplankton by passage through the cooling system [PTCS] was 27.0%. Among them, the FR of microplankton and nanoplankton were 34.1% and 12.4%, respectively. In addition, the FR of diatoms and dinoflagellateswere 33.9% and 29.7%, respectively. These results showed the entrainment effects on microplankton and diatoms by PTCS were higher than those of nanoplankton and dinoflagellates. The FR of total chlorophyll a concentrations were 54.4%, and the FR of microplankton, nanoplankton and picoplankton were 58.9%, 38.5%, and 52.4%, respectively. So the entrainment effects on microplankton by PTCS were higher than those of nanoplankton and picoplankton. The mean FR of carbon assimilation number of phytoplankton was 57.6%, and the seasonal variations of FR of carbon assimilation number ranged from 47.5% to 76.8%. Our results indicated that the phytoplankton species responded differently to power plant operating conditions such as elevated temperature, chlorination, and mechanical impacts.

전동스쿠터용 배터리팩 냉각시스템 개발을 위한 수치해석 (Numerical Analysis on development of the Cooling System for E-Scooter Battery Pack)

  • 이석영
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.30-36
    • /
    • 2016
  • 전동스쿠터용 배터리팩은 상온보다 고온일수록 내부저항이 감소하여 충전효율은 상승하나 배터리 안전성 문제로 인하여 냉각시스템을 필요로 한다. 본 연구의 목적은 냉각용 공기 흡입과 배출 방법과 시기를 다르게 하여 냉각 효율성을 분석하는 것이다. 배터리팩 내부에서 각각의 배터리 사이에 큰 온도편차가 존재하는 경우 배터리의 성능과 효율이 저감된다. 따라서, 배터리팩 냉각성능을 입-출구 냉각팬의 작동 방법 및 시기 변화에 의해 배터리의 성능과 효율을 개선시키도록 한다. 연구에 사용된 수치해석 상용코드는 17.0버젼의 ANSYS CFX이다.

원자로용기 외벽냉각시 원자로공동에서 이상유동 자연순환 해석 (Analysis of Two Phase Natural Circulation Flow in the Reactor Cavity under External Vessel Cooling)

  • 박래준;하광순;김상백;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2141-2145
    • /
    • 2004
  • As part of study on thermal hydraulic behavior in the reactor cavity under external vessel cooling in the APR (Advanced Power Reactor) 1400, one dimensional two phase flow of steady state in the reactor cavity have been analyzed to investigate a coolant circulation mass flow rate in the annulus region between the reactor vessel and the insulation material using the RELAP5/MOD3 computer code. The RELAP5/MOD3 results have shown that a two phase natural circulation flow of 300 - 600 kg/s is generated in the annulus region between the reactor vessel and the insulation material when the external vessel cooling has been applied in the APR 1400. An increase in the heat flux of the inner vessel leads to an increase of the coolant mass flow rate. An increase in the coolant outlet area leads to an increase in the coolant circulation mass flow rate, but the coolant inlet area does not effective on the coolant circulation mass flow rate. The change of the lower coolant outlet to a lower position affects the coolant circulation mass flow rate, but the variation trend is not consistent.

  • PDF

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.

공기 유로 형상에 따른 공랭식 전기자동차 배터리 시스템의 냉각 성능 예측 (Predictions of the Cooling Performance on an Air-Cooled EV Battery System According to the Air Flow Passage Shape)

  • 정석훈;서현규
    • 대한기계학회논문집B
    • /
    • 제40권12호
    • /
    • pp.801-807
    • /
    • 2016
  • 본 논문은 전기자동차 배터리 시스템에 공기를 이용한 직접 냉각 방식을 적용하여, 공기 유로 형상에 따른 냉각 성능을 비교 연구하였다. 이를 위해, 배터리 냉각 시스템에서 모듈의 배치 형상과 발열량을 고정하고, 입 출구 면적 및 외부 Case 형상을 변경하여, 이에 따른 냉각 성능 결과를 수치 해석적으로 비교 분석하였다. 해석 결과는 배터리 내부의 공기 유동 유선(Stream line), 속도장 분포(Velocity field), 온도 분포(Temperature distributions)를 정리하여 제시하였다. 해석 결과, 외기온도 $25^{\circ}C$에서 안정적인 배터리 작동온도인 $50^{\circ}C$ 이하를 만족하기 위해서는 공기의 유입 체적이 $400m^3/h$ 이상이 되어야 함을 확인할 수 있었다. 또한, 출구 부근의 Diffuser 형상을 가지는 해석 조건에서 냉각이 끝난 공기의 배출이 원활히 진행되면서 냉각 성능이 향상되는 것을 알 수 있었다.

열전소자를 이용한 액체 냉각기의 냉각열전달 특성 (Cooling characteristics of a Liquid cooler Using Thermoeletric Module)

  • 박민영;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.197-202
    • /
    • 2007
  • In this study, the cooling characteristics of a liquid cooler using thermoelectric module was experimentally investigated. The experiment was conducted for various inner structures of liquid cooler (4 cases), hot fluid flow rates (0.15-0.25 L/min), number of T.E module (2, 4, 6 set), and the cooling water flow rates (200-600 cc/min) for both parallel and counter flow types. Among the results, better cooling performance geometry was selected. And experiment was also carried out to examine further enhancement of cooling performance by inserting coils (pitches: 0.2, 3, 6 mm) into the hot-fluid channel. Present results showed that the short serpentine type(case2) indicated the best cooling performance. In the case of coil pitch of 3 mm, the best cooling performance was shown, more than 10% increase of the inlet and outlet temperature difference, compared with the case of the cooler without coil. Consequently, the inserted coil pitch should be properly selected to improve cooling performance.

  • PDF

냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하 (Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

엔진 냉각 시스템의 이론적 시뮬레이션 프로그램 개발 (Development of simulation program for automotive engine cooling system)

  • 이승희;신창훈;박원규;양장식;김은필;서정식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.341-346
    • /
    • 2000
  • A numerical simulation has been carried out for the engine cooling system. It is the important element to analysis of heat transfer process in cooling system for an automotive engine. Thus, the purpose of this simulator is to present useful information at the early stages of the design of the cooling system by enabling the development engineer to predict performance trends. This program has useful window interface for analysis of the cooling system and it is convenient for user to control data with relational database. The system was simulated and compared with experimental data. As a result, the inlet, outlet temperature of the radiator by the simulator agrees well with it. It is concluded that this simulation program is available in developing the cooling system for a new car.

  • PDF

이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계 (Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis)

  • 최동수;김용훈;김진세;박천완;정현모;김기석;박종민
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

하나로 2차 냉각탑의 냉각능력 평가 (Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO)

  • 박용철;우종섭;조영갑;류정수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF