• Title/Summary/Keyword: Cooling Fog

Search Result 48, Processing Time 0.033 seconds

Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses (온실의 냉방부하 및 포그시스템의 증발효율 실험분석)

  • Nam, Sang-Woon;Seo, Dong-Uk;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • In order to develop the cooling load estimation method in the greenhouse, the cooling load calculation formula based on the heat balance method was constructed and verified by the actual cooling load measured in the fog cooling greenhouse. To examine the ventilation heat transfer in the cooling load calculation formula, we measured ventilation rates in the experimental greenhouse which a cooling system was not operated. The ventilation heat transfer by a heat balance method showed a relatively good agreement. Evaporation efficiencies of the two-fluid fogging system were a range of 0.3 to 0.94, average 0.67, and it showed that they increased as the ventilation rate increased. We measured thermal environments in a fog cooling greenhouse, and calculated cooling load by heat balance equation. Also we calculated evaporative cooling energy by measuring the sprayed amount in the fogging system. And by comparing those two results, we could verify that the calculated and the measured cooling load showed a relatively similar trend. When the cooling load was low, the measured value was slightly larger than calculated, when the cooling load was high, it has been found to be smaller than calculated. In designing the greenhouse cooling system, the capacity of cooling equipment is determined by the maximum cooling load. We have to consider the safety factor when installed capacity is estimated, so a cooling load calculation method presented in this study could be applied to the greenhouse environmental design.

Development of CFD Model for Estimation of Cooling Effects of Fog Cooling System in Greenhouse (온실 포그냉방시스템의 냉방효과 예측을 위한 CFD 모델의 개발)

  • 유인호;김문기;권혁진
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.11a
    • /
    • pp.78-81
    • /
    • 2001
  • 포그냉방시스템에 관한 연구는 대부분 VETH선도 등을 이용하여 온실 환경이 전체적으로 동질이라는 가정하에서 환기량 및 전체 분무수량 등을 계산하는 정도였으나, 1990년대 중반에 들어서면서 CFD 기법을 이용하여 온실 환경을 보다 정확하게 해석할 목적으로 CFD 기법을 이용하는 연구가 활발하게 이루어지고 있다. (중략)

  • PDF

The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate (환기회수에 따른 포그냉방시스템의 냉방효과)

  • 김기성;김문기;권혁진
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.84-88
    • /
    • 2000
  • 첨단유리온실의 건설이 증가하면서 여름철 온실내 환경의 적정화를 위하여 증발냉각시스템의 도입이 증가하고 있으며, 대표적인 증발냉각시스템은 패드-팬 시스템과 포그시스템 등이 있다. 포그시스템은 냉방효율이 높고 다른 시스템과 비교하여 저비용이며 온실내부공간의 활용면에서 우수한 장점이 있어 그 보급이 증가하고 있다. (중략)

  • PDF

The Cooling Effect of Evaporative Cooling Systems on Greenhouse (증발냉각시스템 설치 온실의 냉방효과)

  • 김기성;김문기;김현수
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.209-212
    • /
    • 1999
  • 여름철 재배시설의 기본적인 온도상승 억제방법은 차광과 환기이지만 이 방법만으로는 작물의 적정 생육온도에 접근하기 어렵기 때문에 추가적인 냉방 장치가 도입되고 있다. 현재 온실의 냉방시스템은 물의 증발잠열을 이용한 Pad and Fan 방식과 Fog 방식의 냉방시스템이 보급되어 있으나, 국내의 지역기상조건을 감안한 연구가 충분히 이루어지지 못하여 냉방시스템의 설치와 운영에 대한 기준이 명확하지 못한 실정이다. 따라서, 본 연구에서는 현장 실험을 통하여 기초적인 자료를 수집하였다.

  • PDF

Temporal and Spatial Variations of Marine Meteorological Elements and Characteristics of Sea Fog Occurrence in Korean Coastal Waters during 2013-2017 (2013~2017년 연안해역별 해양기상요소의 시·공간 변화 및 해무발생시 특성 분석)

  • Park, So-Hee;Song, Sang-Keun;Park, Hyeong-Sik
    • Journal of Environmental Science International
    • /
    • v.29 no.3
    • /
    • pp.257-272
    • /
    • 2020
  • This study investigates the temporal and spatial variations of marine meterological elements (air temperature (Temp), Sea Surface Temperature (SST), and Significant Wave Height (SWH)) in seven coastal waters of South Korea, using hourly data observed at marine meteorological buoys (10 sites), Automatic Weather System on lighthouse (lighthouse AWS) (9 sites), and AWS (20 sites) during 2013-2017. We also compared the characteristics of Temp, SST, and air-sea temperature difference (Temp-SST) between sea fog and non-sea-fog events. In general, annual mean values of Temp and SST in most of the coastal waters were highest (especially in the southern part of Jeju Island) in 2016, due to heat waves, and lowest (especially in the middle of the West Sea) in 2013 or 2014. The SWH did not vary significantly by year. Wind patterns varied according to coastal waters, but their yearly variations for each coastal water were similar. The maximum monthly/seasonal mean values of Temp and SST occurred in summer (especially in August), and the minimum values in winter (January for Temp and February for SST). Monthly/seasonal mean SWH was highest in winter (especially in December) and lowest in summer (June), while the monthly/seasonal variations in wind speed over most of the coastal waters (except for the southern part of Jeju Island) were similar to those of SWH. In addition, sea fog during spring and summer was likely to be in the form of advection fog, possibly because of the high Temp and low SST (especially clear SST cooling in the eastern part of South Sea in summer), while autumn sea fog varied between different coastal waters (either advection fog or steam fog). The SST (and Temp-SST) during sea fog events in all coastal waters was lower (and more variable) than during non-sea-fog events, and was up to -5.7℃ for SST (up to 5.8℃ for Temp-SST).

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan (터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과)

  • Kim, Tae-Kyu;Min, Young-Bong;Kim, Do-Wan;Kim, Myung-Kyu;Moon, Sung-Dong;Chung, Tae-Sang
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.

A Study on the Fog Occurrence in Suyoung Bay (수영만의 안개 발생에 관한 연구)

  • Jo, Gyu-Dae;Kim, Sun-Yeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.3
    • /
    • pp.254-264
    • /
    • 1990
  • Using the meteorological data, surface weather map, and oceanographic data for 5 years(1984-1988). I investigated the characteristics of the fog occurrence and the role of the inshore in Pusan about the fog occurrence. And the meteorological data and sea surface temperature(SST), which were observed in July, 1989 in Suyoung Bay, were compared with those in Pusan. The fogs in Pusan concentrate in May, June and July. And at fog occurrence time the principal wind directions are Southwest(SW) winds, which easily supply with water vapor, and a series of Northeast(NE) wind. At the fog days pressure patterns are pattern 7 in spring time (March, April, and May) and pattern 10 and pattern 13 in summer time (June, July, and August). Also the advection fog(sea fog) is closely related with the relationship between warm and cold advection in 850~700mb and cold and warm SST rather than the increase of the instability of atmosphere in 850~500mb. The fogs in Taegu, which is the inland region, mainly occur at dawn in fall time due to the strong night radiation fog. On the other hand in Pusan the coastal region, the fogs occur from late spring time to summer time (May, June, and July). Because there is the abundant supply of the water vapor from the ocean owing to a series of South(S) wind at this time. Then the atmosphere, which has high relative humidity, reaches easily the supersaturation by the radiation cooling. In Suyoung Bay and Pusan the meteorological observation data, SST and fog days are almost similar. And I think that the mechanism of the fog occurrence nearly accords with both regions.

  • PDF

Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System (지열-열펌프 시스템의 온실냉방 및 육묘 효과)

  • Lee, Jae-Han;Lee, Yong-Beom;Kwon, Joon-Kook;Kang, Nam-Jun;Kim, Hak-Joo;Choi, Young-Hah;Park, Jin-Myeon;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.211-216
    • /
    • 2006
  • This study was carried out to investigate the effect of greenhouse cooling by a geothermal heat pump system on greenhouse temperature and growth of vegetable transplants in summer season. Greenhouse air temperature in day time was $3-4^{\circ}C$ lower in fog plus shading system than in shading, while in night time that was $5-7^{\circ}C$ lower in geothermal heat pump (GHP) plus shading system compared to shading or fogplus shading. system. Plant height of cucumber, tomato and hot pepper transplants was shortened in GHP plus shading compared to shading or fog plus shading system. And Leaf area and dry weight were slightly decreased in GHP plus shading compared to the other systems. Therefore, healthy transplant index on cucumber, tomato and hot pepper was higher in GHP plusshading than in shading or fogplusshading system.

A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity (자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구)

  • Kim, Youngbok;Sung, Hyunsoo;Hwang, Seungjae;Kim, Hyeontae;Ryu, Chanseok
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.31-50
    • /
    • 2016
  • To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.