• 제목/요약/키워드: Cooling Effect

검색결과 2,362건 처리시간 0.031초

Mist를 이용한 저공해 연삭 가공기술 개발 (Development of Low Pollution Grinding Technology using Mist)

  • 최헌종;이석우;김대중;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.793-797
    • /
    • 2000
  • The environmental problems by using coolant demanded the new cooling methods. As one of them the studies on the dry grinding with compressed cold air have been done. The cooling method using compressed cold air was effdve thmugh going down the temperature of compressed air supplied below $-25^{\circ}C$ and inneasing the amount of mmpresd cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using MQL(Minimum Quantity Lubrication) or mist newly were suggested. These two methods can satisfy both cooling effect and lubrication with only small amount of coolant, also has the benefit in the point of decreasing the envimnmental pollution. This paper focused on analyzing the grindmg characteristics of the cooling method using mid. The generated heat and grinding force of the cooling method using mist were compared with them of coolant and compressed cold air. And them grinding test according to the temperature of compressed cold air, mist spray amount and mist supply direction were done.

  • PDF

고속주축의 냉각조건과 후반부 냉각 유무에 따른 열특성 연구 (A Study on the Thermal Characteristics of a High Speed Spindle according to the Cooling Existence of Rear Part and the Cooling Conditions)

  • 최대봉;김수태;이석준;김창용
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.50-55
    • /
    • 2012
  • The important problem in high speed spindle is to reduce and minimize the thermal effect by motor and bearing. This paper presents the thermal characteristic analysis for a high speed spindle with and without cooling at the rear part, considering the viscosity and the flow rate of cooling oil. A high speed spindle is composed of angular contact ceramic ball bearings, high speed built-in motor, oil jacket cooling and so on. The thermal analyses of high speed spindle need to minimize the thermal effect and maximize the cooling effect and they are carried out under the various cooling conditions. Heat generations of the bearing and the high speed motor are estimated from the theoretical and experimental data. This result can be applied to the design and manufacture of a high speed motor spindle.

대구의 여름철 야간 냉각량과 기상요소와의 관련성 연구 (A Study on the Relationship between the Summertime Night Cooling Rate and Meteorological Elements in Daegu)

  • 김하영;김해동
    • 한국환경과학회지
    • /
    • 제30권10호
    • /
    • pp.821-831
    • /
    • 2021
  • The relationship between night cooling rate and meteorological elements was investigated over the past five years (2016-2020), using weather data from the new (Daegu(143)) and old (Shinam(860)) Daegu Regional Meteorological Agency located in the suburban and urban regions, respectively. There was a correlation between the total daily amount of solar radiation (Stot) and the night cooling rate in the both regions. However, a higher correlation was observed at the new Daegu Regional Meteorological Agency station (Daegu(143)). In particular, data from the new Daegu Regional Meteorological Administration's observatory, which experiences a low thermal storage effect caused by artificial structures, showed a higher correlation between nighttime cooling and weather factors. The reason for this is that the lesser the heat storage effect caused by the artificial structures, the better the effect of surface radiation cooling on temperature reduction. These findings confirm that the correlation between night cooling and weather factors can be used to assess the impact of artificial structures in cities.

히트펌프 냉·난방 시스템의 온도 자동제어에 관한 연구 (A Study for Automatic Temperature Control of the Heating-Cooling System with Heat Pump)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권4호
    • /
    • pp.143-149
    • /
    • 2011
  • The experiment has been investigated the room temperature change under adjusting 4-way valve which was installed for cooling and heating switch. Beside, the temperature of heat pump was controlled automatically for autonomously adjusting temperature and maintaining a constant room temperature. As results, Inlet & outlet temperature differences of compressor are $95^{\circ}C$ in cooling condition and $57^{\circ}C$ in heating condition. Therefore, Compression efficiency of cooling effect is higher than heating effect. In addition, Heat exchange effect of Cooling system condition is higher than heating system. This results can be used for studying about automatic temperature control of cooling and heating system with heat pump and 4way valve.

카본/나일론 복합재료의 냉각속도에 따른 기계적 특성변화 (Effect of Cooling Rate on Mechanical Properties of Carbon/Nylon66 Composites)

  • 홍순곤;변준형;황병선;강범수
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.122-125
    • /
    • 2001
  • The objective of this research is to develop hybridized yarns for thermoplastic composites, and to examine tile effect of cooling rate on mechanical properties of the composites. The co-braided yarn utilizing carbon fibers as reinforcements and Nylon 66 fibers as matrix materials has been fabricated. Thermoplastic composites have been manufactured by the hot-press forming process. For the processing conditions, cooling rates of $-2.5^{\circ}C$/min and $-60^{\circ}C$/min have been considered. Three-point bending test and losipescu shear test were performed to investigate the effect of the cooling rate and the surface treatment of carbon fibers. SEM photographs were used to investigate the fracture surfaces of the tested samples. The cooling rate of $-60^{\circ}C$/min resulted in the higher strength and elastic modulus for bending and shear tests. The composites of the epoxy-sized carbon fibers showed the lowest strength due to the degradation of the sizing material during the thermoforming process.

  • PDF

보텍스튜브를 이용한 충돌냉각의 실험적 연구 (An Experimental Investigation of Jet Impingement Cooling Using the Vortex Tube)

  • 신운철;김창수;배신철
    • 대한기계학회논문집B
    • /
    • 제31권1호
    • /
    • pp.8-15
    • /
    • 2007
  • The jet impingement cooling characteristics are investigated experimentally. The study is motivated by the potential application of local hot spot cooling by means of the vortex tube. The purposes of this research are to examine the effect of the nozzle-block spacing and flow rate. The results of jet through vortex tube is compared with ones of circular Jet. Flow visualization by the smoke-wire technique is also performed to investigate the flow structure. As the nozzle-block spacing is increased and flow rate decreased, the cooling effect of the Jet through the vortex tube decreases mere remarkably than that of the circular jet. So the cooling effect for the jet through the vortex tube is higher than that for the circular jet at $H/D{\leq}3$, $Q{\geq}10m^3/h$.

화기삼의 효능주장과 미국삼의 발전과정에 관한 고찰 (A Study on the Cooling Effect Claim & Development Procedure of the American Ginseng)

  • 이동필
    • Journal of Ginseng Research
    • /
    • 제30권3호
    • /
    • pp.158-164
    • /
    • 2006
  • The American ginseng is getting popular in the world market with cooling effects. This paper study history of the cooling effect of American ginseng. Most references include one's assertion on the cooling effect of American ginseng based on the old chinese believe. However, American ginseng was discovered in 1716 and export to China from mid 18 century. Concerning on the time period for clinical demonstration to get people's believe, it is not sufficient to conform the cooling effects of American ginseng. That is why the American ginseng was sold as an inferior goods compare oriental ginseng until mid 1970s. United State FDA also does not certify any effectiveness of Ginseng yet. However, it is important to study on the American ginseng because of rapid growth in the world ginseng market.

냉각탑 주위의 장애물에 의한 재순환 현상에 관한 수치해석 (Numerical Analysis on Recirculation Generated by Obstacles around a Cooling Tower)

  • 이정희;최영기
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.578-586
    • /
    • 2006
  • The present study has been conducted to examine the effect of obstacles around a cooling tower and an air-guide to prevent recirculation. In order to analyze the interaction between external flow and cooling tower exit flow, the external region as well as the cooling, tower are included in computational domain. Two dimensional analysis is performed using the finite volume method with non-orthogonal and unstructured grid system. The standard ${\kappa}-{\varepsilon}$ turbulence model is used. To investigate the recirculation phenomena, flow and temperature fields are calculated with three approaches such as, the distance between cooling tower and obstacle, the allocated geometrical type, and the effect of height of obstacle. In addition, the air-guide is considered in the current computation. The mean recirculation rate increases with the height of obstacle. The effect of air-guide to reduce the mean recirculation rate is obviously observed.

BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구 (A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System)

  • 이충식;이응직;이철구
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions)

  • 박찬우;조현철;강용태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.