• 제목/요약/키워드: Cooling Down

검색결과 431건 처리시간 0.026초

광섬유 고속생산용 헬륨 주입식 유리섬유 냉각공정에 대한 열유동 해석 (THERMO-FLUID ANALYSIS ON THE HELIUM INJECTION COOLING OF GLASS FIBER FOR HIGH SPEED OPTICAL FIBER MANUFACTURING)

  • 오일석;김동주;곽호상;김경진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.92-95
    • /
    • 2011
  • In manufacturing optical fibers, the process starts with the glass fiber drawing from the heated and softened silica preform in the furnace, and the freshly drawn glass fiber is still at high temperature when it leaves the glass fiber drawing furnace. It is necessary to cool down the glass fiber to the ambient temperature before it then enters the fiber coating applicator, since the hot glass fiber is known to cause several technical difficulties in achieving high quality fiber coating. As the fiber drawing speed keeps increasing, a current manufacturing of optical fibers requires a dedicated cooling unit with helium gas injection. A series of three-dimensional flow and heat transfer computations are carried out to investigate the effectiveness of fiber cooling in the fiber cooling unit. The glass fiber cooling unit is simplified into the long cylindrical enclosure at which the hot glass fiber passes through at high speed, and the helium is being supplied through several injection slots of rectangular shape along the cooling unit. This study presents and discusses the effects of helium injection rates on the glass fiber cooling rates.

  • PDF

The effect of cooling rates on carbide precipitate and microstructure of 9CR-1MO oxide dispersion strengthened(ODS) steel

  • Jang, Ki-Nam;Kim, Tae-Kyu;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.249-256
    • /
    • 2019
  • The 9Cr-1Mo ferritic-martensitic ODS steel is a promising structural material for the next generation nuclear power plants including fast reactors for application in reactor vessels and nuclear fuel. The ODS steel was cooled down by furnace cooling, air cooling, oil quenching and water quenching, respectively, after normalizing it at $1150^{\circ}C$ for 1 h and then tempering at $780^{\circ}C$ for 1 h. It is found that grain size, a relative portion of ferrite and martensite, martensitic lath configuration, behaviors of carbide precipitates, and hardness of the ODS steel are strongly dependent on a cooling rate. The grain size and martensitic lath width become smaller with the increase in a cooling rate. The carbides were precipitated at the grain boundaries formed between the ferrite and martensite phases and at the martensitic lath interfaces. In addition, the carbide precipitates become smaller and more widely dispersed with the increase in a cooling rate, resulting in that the faster cooling rate generated the higher hardness of the ODS steel.

비등온 급기조건에서 환기방식에 따른 환기효율 특성에 관한 연구 (A Study on Ventilation Effectiveness in the Non-isothermal Supply using Mixing and Displacement Ventilation Systems)

  • 이재근;강태욱;윤석구;구재현;한정균;조민철
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.739-745
    • /
    • 2001
  • The objective of this research is to analyze the ventilation effectiveness in the non-isothermal air supply using mixing and displacement ventilation systems for indoor air quality control and management. In this study, a ventilation effectiveness is evaluated in a simplified model chamber using a tracer gas technique of $CO^2$ gas injected into a supply duct as a function of ventilation rates, supply/extract sites and cooling/heating air supply. The ventilation effectiveness decreased with increasing ventilation rate on the cooling and heating conditions. And the ventilation effectiveness of case 3 (down supply and upper extract) was better thant that of case 1(upper supply and upper extract) and case 2(upper supply and down extract) with the cooling supply conditions. but for the heating supply air conditions, the ventilation effectiveness of case 2 was better than that of case 3 and case 1.

  • PDF

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.

Gifford-McMahon 극저온 냉동기의 특성에 관한 실험적 연구 (An experimental study on the characteristics of Gifford-McMahon cryocooler)

  • 정철진;고득용
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.71-76
    • /
    • 2002
  • To achieve good cryogenic circumstances by Gifford-McMahon cryocooler, we have to constitute optimal conditions with various factors for G-M cryocooler. In this study, cool-down characteristics were presented with some factors using brass matrix mesh (1st stage) and Pb ball (2nd stage) as regenerator materials for the heat exchangers. The effects of the variations of Helium gas pressure and cycle frequency on the cooling capacity of G-M cryocooler are investigated experimentally. The presented results could be summarized as follows : 1) As the steady state pressure increases, 'no load temperature' decreases but cooling capacity increases. 2) It is confirmed that the characteristics of the specific heat of the regenerator materials agree well with the cool-down characteristics of 10 K cryocooler.

  • PDF

30kVA 초전도 전동기의 기기상수 (Machine Constants of 30 kVA Superconducting Synchronous Motor)

  • 최경달;한송엽;츠키지히로시;호시노토모노리;무타이쯔야
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1996
  • For the test of the operating characteristics as a moor, a 20 kVA super conducting synchronous machine with rotating field windings has been made in Saga university, Japan from 1991. Before the load tests of it as a motor, we carried out cooling down tests and measured its machine constants. During the cooling down tests, we found that the rotor itself had no cryogenic problem, but the inlet part for liquid He had one. Though enough liquid He couldn't be accumulated inside the rotor because of this problem, we drove field currents up to 20 A and could acquire the machine constants and V curves of the super-conducting synchronous motor.

  • PDF

후열처리 과정에서 냉각조건에 따른 Bi계 초전도선재의 임계특성 (Critical Properties of Bi Superconducting Wire with Cooling Condition in the Sintering Process.)

  • 김민기;최효상;정동철;최명호;한병성
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.958-964
    • /
    • 1994
  • To study on the superconducting properties with cooling conditions, silver-sheathed Bi-Pb-Sr-Ca-Cu-O wires fabricated by the powder-in-tube method. The wires cooled down in the furnace, air and liquid NS12T after sintering at 840$^{\circ}C$ Critical current density of sample cooled in the furnace is 5.1${\times}$10S03TA/cmS02T and sample cooled in the air is 40A/cmS02T at 77K, zero magnetic field. The latter is very low critical current density of Bi system. 2223 high-Tc superconducting phase of sample cooled in the air was distroyed. Properties of sample cooled down in the liquid nitrogen is the same as cooled in the furnace.

Pressure-Temperature Limit Curve of Reactor Vessel by ASME Code Section III and Section XI

  • M.J. Jhung;Kim, S.H.;Lee, T.J.
    • Nuclear Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.498-513
    • /
    • 2001
  • Performed here is a comparative assessment study for the generation of the pressure- temperature (P/T) limit curve of the reactor vessel. Using the cooling or heating rate and vessel material properties, the stress distribution is obtained to calculate stress intensity factors, which are compared with the material fracture toughness to determine the relations between operating pressure and temperature during cool-down and heat-up. P/T limit curves are generated with respect to crack direction, clad thickness, toughness curve, cooling or heating rate and neutron fluence, and their results are compared.

  • PDF

MOSS형 LNG선의 방열구조에 의한 비정상 온도분포해석에 관한 연구 (A Study on Unsteady Temperature Distribution Analysis of Moss Type LNG Carrier by Insulation System)

  • 김진구;김용모;김춘식
    • 한국해양공학회지
    • /
    • 제11권4호
    • /
    • pp.159-168
    • /
    • 1997
  • 본 연구는 Moss형 LNG선박의 방열구조에서 LNG탱크에 침입하는 열량과 선체의 온도분포를 예측하고, 운항 중 LNG탱크를 Cooling down(예냉)하는 경우 발생하는 비정상상태에서 LNG탱크에 발생하는 국부적인 열응력을 검토할 수 있는 비정상 온도분포해석과 LNG증발량을 검토하였다. 특히 운항 중인 선박을 대상으로 일반적인 수치계산시에 필요한 각종 입력절차를 간소화 하고 경계조건 선정시에 비 전문가도 쉽게 이용할 수 있는 전산프로그램을 개발하였다. Moss형 LNG탱크의 예냉작업에 필요한 최적의 냉매량과 예냉조건을 비정상상태에서 해석한 것은 설계자 및 선박 운항자에게 유용하게 이용될 것이다.

  • PDF

6.6kV/200A급 유도형 한류기용 과냉질소 냉각시스템의 특성 (Characteristic of sub-cooled nitrogen cryogenic system for 6.6kV/200A Inductive Superconducting Fault Current Limiter)

  • 박동근;강형구;윤경용;주민석;김태중;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.234-236
    • /
    • 2003
  • The cryogenic system for inductive superconducting fault current limiter (SFCL) has been investigated recently. In this investigation, the sub-cooled nitrogen cryogenic system was adopted to enhance the performance of DC reactor for 6.6㎸/200A inductive SFCL. In sub-cooled nitrogen state at 64K, the critical current value and the thermal conductivity are larger than those of saturated nitrogen state at 77K and the electrical insulation capacitance should be remarkably enhanced. The solenoid type of 84mH superconducting DC reactor was fabricated and cooled down to 64K by using sub-cooled cooling method with GM-cryocooler and rotary pump. The fabrication techniques of cryogenic system and some experimental results such as cooling down characteristic are introduced in this study. Moreover, the sub-cooled nitrogen cryogenic system was detailedly introduced in this paper.

  • PDF