An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump (가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구)

  • 김봉훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

A study on the Operating Characteristics of the Capsule-type Ice Storage System (캡슐형 빙축열 시스템의 운전특성에 관한 연구)

  • Kim, Kyung-Hwan;Cho, Sung-Woo;Choi, Jeong-Min;Ha, Suk-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.199-204
    • /
    • 2005
  • The decrease of summer peak electric load of our country is very important. The government is arranging a lot of support policies and statutes. etc. to decrease of peak electric load. And ice storage system is known as one of the alternatives. The purpose of this study is to collect basic data for operating characteristics to plan the most suitable operation of capsule-type ice storage system. The storaging tank is designed to take charge 40% of total cooling load in building, In operation condition the storage tank took charge 50%. Coefficient Of Performance of daily screw refrigerator is around 4.

  • PDF

An Analysis on the Performance and the Heat Transfer of Molten Carbonate Fuel Cell Stack (용융탄산염 연료 전지 스택의 성능 및 열전달 해석)

  • Koo, J.Y.;Suh, J.C.;Kim, Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.120-129
    • /
    • 1994
  • A numerical investigation has been carried out for the electrochemical reaction, mass and heat transfer characteristics of the Molten Carbonate Fuel Cell(MCFC) stack. The effects of cooling air channel and water gas shift reaction were taken into account. The current density distribution of electrodes, the molecular fractions of reactant gasses and three dimensional temperature distribution can be calculated and shown by several lines of equivalent values. The results have been compared with the existing ones, and reasonable agreement has been obtained. To examine the influence of changing parameters, such as the composition of reactant gases, the target average current density, the utilization of reactant gases, the cooling air inlet temperature and flow rates, the computer simulation has been done. The analysis method and computer program developed in this study will be greatly helpful to design and verify the optimum operating condition of MCFC stack.

  • PDF

Evaluation of the Device Temperature and Optical Characteristics in High Power White LED Lamp by Driving Condition (고출력 백색 LED 램프의 구동조건에 따른 온도 및 광 특성 평가)

  • Yun, Jang-Hee;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.33-38
    • /
    • 2011
  • In this paper, the effect of pulse current and generated heat on characteristics of the LED is measured and evaluated. For experiments, the LED driving circuit and digital logic which determines period and duty ratio of lighting are designed. At rated current, the temperature and optical characteristics of the LED with change in duty ratio and period are compared, and those of the LED with change in duty ratio and existence of cooling fan are also compared at constant average current. As a result, frequency does not affect device temperature and optical characteristic of the LED but duty ratio does. Also, the cooling fan is less effective on those of the LED at rated current.

Optimization of a straight fin heat sink in 3D LCos projector considering bypass flow and a flow barrier

  • Kim, Jin-Wook;Kim, Sang-Hoon;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1265-1268
    • /
    • 2009
  • In this paper, the effect of a flow barrier and bypass on the cooling performance for a straight fin heat sink is presented. Both side directions and upward direction of bypass are controlled using various ducts which have different width and heights. In addition, a flow barrier is used to control flow toward heat sink. Through experiments, the distance from leading edge of a heat sink to a flow barrier is varied for various bypasses under fixed volume flow rate condition. This study shows possibility to improve cooling performance when bypass and a flow barrier exist.

  • PDF

Influence of surfactant on heat transfer of air-cooled vertical absorber (공냉식 수직 흡수기의 열전달에 미치는 계면활성제의 영향)

  • 윤정인;권오경;문춘근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.740-748
    • /
    • 1999
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare inner surface, groove inner surface, corrugated inner surface and spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of film Reynolds number in the range of 20~200. Experiments were tarried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.

  • PDF

A Numerical Study on Automobile Interior Environment (자동차 실내 환경에 관한 수치적 연구)

  • Jeon, Hee-Ho;Ko, Seok-Bo;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2007
  • The latest cars give much importance in the role of HVAC system that controls the environment of the area for passengers more than just basic capability In this study, we drew the automobile interior as three dimension and arranged a method of numerical analysis on HVAC environment in the automobile interior displaying air current distribution and temperature distribution through simulation of the automobile interior on the ventilation volume and outlet area, The aim of this study is to develop the estimated method for HVAC environment in the automobile interior. Results of numerical analysis, to cool automobile interior needs more considerations if thinking cheerful surroundings of automobile interior air but the more magnitude of outlet is small, the more cooling capability is excellent and realistic countermeasures about a realistic geometry and boundary condition.

Numerical Analysis on the Heat Transfer Characteristics of Syngas Cooling System of an IGCC Process (IGCC 합성가스 냉각 시스템의 열전달 특성 연구)

  • Oh, Junho;Ye, In-soo;Park, Sangbin;Ryu, Changkook;Park, Sungku
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.65-68
    • /
    • 2013
  • In a syngas cooling system of coal gasification process, fly slag carried by syngas deposit on the surface of heat exchanger. The deposited materials form a fouling layer with several millimeters thickness, disturbing heat transfer between steam and syngas. This study investigates flow and heat transfer characteristics of syngas in helical coil heat exchanger using computational fluid dynamics under clean and fouled surface condition. Process model were also designed and its results are in good agreement with CFD results.

  • PDF

A study on the machinability of ceramics in zirconia system by low temperature cooling (지르코니아계 세라믹스의 저온냉각절삭과 공구마멸 해석에 관한 연구)

  • 김정두
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.59-70
    • /
    • 1990
  • Crack of breaking toughness of most Ceramics material is 1-5MPa .root.m but that of Zirconia Ceramics is improved to be 6-8MPa .root.m and its development of machining difficult-to-machine material is on the rise as urgent subject. For general Zirconia Ceramics machining, diamond grinding wheel is generally used by selecting an appropriate one and establishing grinding condition but due to such limitations as economics, grinding efficiency and machining geometry, great interest in machining method being used for diamond tool is emphasized. But it is reported that diamond tool is oxidized by cutting heat in the air and is graphitized in vacuum, which causes bad effects on tool life. In this study, to restraint cutting heat the internal side of tool is cooled, and restraint low temperature cooling system and being experimented. Further, the machinability of diamond tool for Zirconia Ceramics machining is analyzed with respect to tool wear and stress.

  • PDF

Development of Control System for Transversal Temperature of Strips in Hot Strip Mills (열간압연공정에서의 스트립 폭방향 온도제어 시스템 개발)

  • Choi, Jae-Chan;Lee, Sung-Jin;Park, Bong-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1202-1215
    • /
    • 1996
  • In this study, in order to achieve the uniformity of mechanical properties and microstructures of a hot-rolled coil in the transversal direction, the edge mask device is newly device is newly developed and installed at the upper laminar-flow cooling head in the run out table, which controls the transversal temperature of strip with enco panel and bar edge heater. The device that is transversally movable prevents the temperature drop of strip edge by blocking the cooling water into the strip edge. So, the pattern of edge mask set-up condition of the device was derived by analyzing the characteristics of strip temperature and mechanical properties according to the on-line application of edge mask.