• 제목/요약/키워드: Coolant pump

검색결과 204건 처리시간 0.028초

두 대의 펌프가 병렬로 설치된 장치의 유량 특성 (FLOW CHARACTERISTICS OF A SYSTEM WHICH HAS TWO PARALLEL PUMPS)

  • 박정근;박종호;박용철
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.1-8
    • /
    • 2012
  • During a reactor normal operation, two parallel 50% capacity cooling pumps circulate primary coolant to remove the fission reaction heat of the reactor through heat exchangers cold by a cooling tower. When one pump is failure, the other pump shall continuously circulate the coolant to remove the residual heat generated by the fuels loaded in the reactor after reactor shutdown. It is necessary to estimate how much flow rate will be supplied to remove the residual heat. We carried out a flow network analysis for the parallel primary pumps based on the piping network of the primary cooling system in HANARO. As result, it is estimated that the flow rate of one pump increased about 1.33 times the rated flow of one pump and was maintained within the limit of the cavitation critical flow.

캔드모터펌프의 성능해석 (PERFORMANCE ANALYSIS OF CANNED MOTOR PUMP)

  • 고성호;김연태;곽영균;강민구;한승열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.181-186
    • /
    • 2010
  • A numerical study was conducted to predict the performance curve of a canned motor pump for SMART(System Integrated Modular Advanced ReacTor). The study used a computational domain which included not only the pump but also a suction pipe and a volute casing with a discharging pipe in order to simulate an experimental setup. The ANSYS CFX program was utilized to obtain flow characteristics inside the pump as well as the overall pressure rise across the pump operating on- and off-design points. Computed results showed that the performance of the pump at off-design points was much lower than expected. Special attention was made to find the cause of the low performance of the pump operating at low flow rate.

  • PDF

The Characteristics of a Pump at Nearly Saturated State

  • Kim, S. N.;Kim, J. C.
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 1998
  • A set of experiments using a 1/10 scale model pump which was manufactured to simulate performance of reactor coolant pump(RCP) of Y.G.N # 3 and 4, was executed in single phase(at atmospheric pressure and room temperature) and near-saturation(300 ~ 600kPa). The pump characteristics in single phase flow was similar to the characteristics of the RCP. The pump characteristic curves at nearly saturated state were correlated in terms of flow coefficient and head coefficient for subcooled temperature using the cavitation number defined as (equation omitted), which can be predicted the cavitation possibility. The pump behavior around the saturated temperature almost consists with single phase behavior until the cavitation occurs(When cavitation occurs. When the flow coefficient is about 0.12), the pump head rapidly degrades. In this situation, subcooled temperature is about 1.8~8$^{\circ}C$ and cavitation number of model pump is 1.0 ~ 1.7.

  • PDF

전산유체해석을 통한 RE엔진 냉각수 코어의 성능 개발 (Performance Development of Coolant Core for Range Extender Engine Using CFD Simulation)

  • 김창수;박성영
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2075-2080
    • /
    • 2013
  • 본 논문에서는 RE엔진에 적용하기 위한 냉각수 코어를 CFD 기술을 활용하여 개발하였다. 개선 모델은 배기밸브 주위와 사이의 온도를 저감하기 위한 냉각수 우회부를 추가하였다. 2번 실린더 블록 주위와 배기밸브 사이의 유량이 증가하였기 때문에, 베이스 모델대비 개선 모델의 유량 정체가 개선되었다. 결과적으로, 배기밸브 주위에서의 열전달이 향상되고, 전 유량 구간에서 기존 모델 대비 약 5%의 압력 강하량 저감 효과를 보이는 개선 모델을 얻을 수 있었다. 압력 강하량의 저감은 상응하는 냉각수 펌프의 부하를 저감하고 연비에 긍정적 영향을 미칠 것으로 판단된다.

연료전지 자동차 열방출 시스템의 설계 (Design of a Heat Release System for Fuel Cell Vehicles)

  • 김성철;박민수;정승훈;윤석호;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.545-548
    • /
    • 2005
  • There is a close relation between the heat generation in the fuel cell stack and the fuel cell performance. In PEM fuel Gell vehicles, the stack coolant temperature is about $65^{\circ}C$, which is far lower than that for general automobile engine. Therefore, it is hard to release heat generated in the stack by using a radiator of limited size because of the reduced temperature difference between the coolant and the ambient air. In this study, indirect stack cooling system using $CO_2$ heat pump was designed and its stack cooling performance in releasing heat to the ambient was investigated. This work focuses on a series of processes that grasp the relation among the fuel cell power, the radiator capacity and the stack temperature. The purpose of this work is to find out a way to properly release sufficient amount of heat through the finite sized radiator, so that the stack power general ion can not be deteriorated due to the stack temperature increase. The optimization between the compressor power consumption and the fuel cel1 output power can be carried out to maximize the performance of fuel cell system.

  • PDF

연료전지 자동차 열방출 시스템의 설계 (Design of a Heat Release System for Fuel Cell Vehicles)

  • 김민수;김성철;박민수;정승훈;윤석호
    • 신재생에너지
    • /
    • 제1권4호
    • /
    • pp.49-54
    • /
    • 2005
  • There is close relation between the heat generation in the fuel cell stack and the fuel performance. In PEM fuel cell vehicles, the stack coolant temperature is about $65^{\circ}C$, which is far lower than that for general automobile engine. Therefore, it is hard to release heat generated in the stack by using a radiator of limited size because of the reduced temperature difference between the coolant and the ambient air. In this study, indirect stack cooling system using $CO_2$ heat pump was designed and its stack cooling performance in releasing heat to the ambient was investigated. This work focuses on a series of processes that grasp the relation among the fuel cell power, the radiator capacity and the stack temperature. The purpose of this work is to find out a way to properly release sufficient amount of heat through the finite sized radiator, so that the slack power generation can not be deteriorated due to the stack temperature increase. The optimization between the compressor power consumption and the fuel cell output power can be carried out to maximize the performance of fuel cell system.

  • PDF

막냉각이 적용된 액체로켓엔진의 비추력 최적조건 (Optimal Condition of Specific Impulse for a Liquid Rocket Engine with Film Cooling)

  • 조원국;박순영;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.135-140
    • /
    • 2007
  • 막냉각이 적용된 액체로켓엔진의 비추력 최적조건을 분석하였다. 본 연구에서 구한 엔진의 비추력 성능을 문헌에 소개된 가스발생기 사이클 엔진의 개념설계와 비교하여 적절한 정확성을 가지는 것을 확인하였다. 비추력을 극대화할 수 있는 조건으로 최적의 막냉각 유량과 재생냉각 용량의 조합이 제시되었다. 추력이 증가될 경우, 막냉각 유량이 감소하고 연료펌프 차압은 증가한다. 터빈 입구온도 증가에 따라 최적 조건의 막냉각 유량과 연료펌프 차압이 증가한다. 코킹 온도 증가 역시 터빈 입구온도와 정성적으로 동일한 영향을 가진다.

  • PDF

원자로 냉각재 펌프 고장예측진단을 위한 데이터 분석 플랫폼 구축 (Data Analysis Platform Construct of Fault Prediction and Diagnosis of RCP(Reactor Coolant Pump))

  • 김주식;조성한;정래혁;조은주;나영균;유기현
    • 한국IT서비스학회지
    • /
    • 제20권3호
    • /
    • pp.1-12
    • /
    • 2021
  • Reactor Coolant Pump (RCP) is core part of nuclear power plant to provide the forced circulation of reactor coolant for the removal of core heat. Properly monitoring vibration of RCP is a key activity of a successful predictive maintenance and can lead to a decrease in failure, optimization of machine performance, and a reduction of repair and maintenance costs. Here, we developed real-time RCP Vibration Analysis System (VAS) that web based platform using NoSQL DB (Mongo DB) to handle vibration data of RCP. In this paper, we explain how to implement digital signal process of vibration data from time domain to frequency domain using Fast Fourier transform and how to design NoSQL DB structure, how to implement web service using Java spring framework, JavaScript, High-Chart. We have implement various plot according to standard of the American Society of Mechanical Engineers (ASME) and it can show on web browser based on HTML 5. This data analysis platform shows a upgraded method to real-time analyze vibration data and easily uses without specialist. Furthermore to get better precision we have plan apply to additional machine learning technology.

소형 환단면 선형유도전자펌프 설계를 위한 전산 프로그램 개발 (Development of Computer Program for Design of the Small Annular Linear Induction EM Pump)

  • 김희령;남호윤;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.137-140
    • /
    • 2002
  • EM(ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study, computer program for the pilot annular linear EM pump has been developed for the maximum flowrate with 200 l/min and maximum developing pressure with 3 bar. Firstly, Balance equation is induced by the equivalent circuit method which is commonly employed to analyze linear induction machines and the calculation of the hydraulic pressure drop. Then, design equation is converted to the computer program and optimum pump variables are determined by this code. The code is verified by the comparative analysis with the characteristic of the commercialized pump.

  • PDF