초록

During a reactor normal operation, two parallel 50% capacity cooling pumps circulate primary coolant to remove the fission reaction heat of the reactor through heat exchangers cold by a cooling tower. When one pump is failure, the other pump shall continuously circulate the coolant to remove the residual heat generated by the fuels loaded in the reactor after reactor shutdown. It is necessary to estimate how much flow rate will be supplied to remove the residual heat. We carried out a flow network analysis for the parallel primary pumps based on the piping network of the primary cooling system in HANARO. As result, it is estimated that the flow rate of one pump increased about 1.33 times the rated flow of one pump and was maintained within the limit of the cavitation critical flow.

키워드

참고문헌

  1. 1996, Y.C. Park, J.S. Wu, "System Performance Test in HANARO," the 5th ASRR, Vol.1, pp.240-246.
  2. 2004, Y.C. Park et. al, "Improvement of Temperature Control Function for HANARO Flow Simulation Test Facility," Proceedings of the Korean Nuclear Society Spring Meeting, pp.97.
  3. 2005, Y.C. Park, S.I. Woo, "The Analytic Analysis of Suppressing Jet Flow at Guide Tube of Circular Irradiation Hole in HANARO," J of Computational Fluids Engineering, Vol.10 No.2, pp1-6.
  4. 2000, Y.C. Park et al., "Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO," Proceeding of the KFMA Annual Meeting 2000, pp.345-350.
  5. 2007, Y.C. Park, et, al., 2007, "The Results of the Emergency Water Core Injection Flow Rate Test in HANARO," Transactions of the Korean Nuclear Society 2007 Autumn Meeting.
  6. 1999, Y.C. Park, et al., "Design and Test of ASME Strainer for Primary Cooling System in HANARO," Journal of Fluid Machinery, Vol.2 No.3, pp.24-29.
  7. 1985, Flow Network Analysis, 5.0C, "User's Manual," Kelix Software Co.
  8. 1981, Hooper, W. B. "The Two-K Method Predicts Head Losses in Pipe Fittings," Chem. Engr. Aug. 24. pp.97-100.
  9. Merie C. Potter and Elaine P. Scott, "An Introduction to Fluid Mechanics," Thomson.
  10. 1983, Hydraulic Institute, "Hydraulic Institute Standards for Centrifugal Rotary & Reciprocating Pumps," 14th. Edition.

피인용 문헌

  1. Numerical analysis of non-equilibrium steam condensing flows in various Laval nozzles and cascades vol.11, pp.1, 2017, https://doi.org/10.1080/19942060.2016.1267043