• Title/Summary/Keyword: Cool surface ratio

Search Result 15, Processing Time 0.022 seconds

Comparative Evaluation of Cool Surface Ratio in University Campus: A Case Study of KNU and UC Davis (대학 캠퍼스의 쿨표면 비율 비교평가: 경북대학교와 UC Davis를 사례로)

  • Hwang, Young-Seok;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.117-127
    • /
    • 2015
  • The cool surface ratio could be used as a proxy of the overall thermal environment contributing to heat islands in urban area. This research proposes a comparative evaluation framework in an objective and quantitative way for measuring cool surface ratios. Two university campuses (Kyungpook National University: KNU, South Korea and UC Davis: University of California, Davis, USA) were selected as case study sites in order to monitor cool surface condition. Google Earth combined with digital maps realistically identified the major type of cool surfaces such as cool roofs and water bodies in the study area. Cool surfaces were sparsely identified over the KNU campus while the UC Davis campus was heavily covered by cool surfaces such as cool roofs and water bodies, resulting in almost four times more first-grade cool surfaces, as compared to KNU. It is confirmed that standard remote sensing technology can offer the viable method of measuring and comparing the campus-wide cool surface condition. It is anticipated that this research output could be used as a valuable reference to initiate a nation-wide cool surface strategy since objective evidence has been provided based on area-wide measurement for the cool surface in the two university context.

Flooding Tolerance of Cool-Season Turfgrass for the Revegetation of Waterside Slopes (수변 비탈면 녹화를 위한 한지형잔디의 내침수성 연구)

  • Shim, Sang-Ryul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.2
    • /
    • pp.45-52
    • /
    • 2015
  • Cool-season turfgrass is a rapidly increasing of usage for the revegetation of waterside slopes in dams, lakes and rivers. The purpose of this research is to identify the flooding tolerance of cool-season turfgrass with respect to the flooding periods of 0(control), 2, 4 and 6 days, respectively. The surface coverage ratio, turfgrass injury and soil moisture content were measured to assess the flooding tolerance of cool-season turfgrass. The increase in the flooding periods with 4 and 6 days resulted in the lower surface coverage ratio for cool-season turfgrass while no significant difference was found in the 2 days flooding when compared to 0 day (the control plot) flooding plot. In case of the turfgrass injury and the soil moisture content, however, the higher values were found with the increase of flooding periods in 2, 4 to 6 days. We observed that the higher the turfgrass injury and soil moisture content increased, the lower the surface covrage ratio decreased. In these regards, we also observed that the tolerance of cool season turfgrass were high in the 2 days flooding condition, medium in the 4 days flooding condition and low in the 6 days flooding condition. The flooding tolerance of cool-season turfgrass was gradually weakened in over 2 days flooding periods due to $O_2$ deficiency in the anaerobic soil condition. Therefore, we could suggest cool-season turfgrass within 2 days flooding periods for the revegetation of waterside slopes in dams, lakes and rivers.

Development of Triacetate-containing Functional Coolness Fabrics with Cool-Touch and Cool-Absorbent (접촉 냉감 및 흡수 냉감을 갖는 트리아세테이트 함유 기능성 냉감 직물 개발)

  • Kim, Myoung Ok;Lee, Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.5
    • /
    • pp.799-808
    • /
    • 2018
  • This study develops triacetate-containing functional fabrics with a cool-touch and cool-absorbent. For this purpose we used composite yarns made using triacetate filament and PET High absorbance quick dry filament as well as the composite fabric woven. The fineness of the yarn and structure of fabric varied the cover factor varied. The blend ratio of triacetate was differently set. When the triacetate content was the same, the cool touch of the fabric having a large cover factor and small SMD increased. The surface became smooth and the contact area became large; in addition, both the Qmax value and the cool-touch became large. In the case of similar density, the cool-touch of the fabric having a large content of triacetate increased. The cool-absorbent of the fabric containing triacetate showed a similar level of the PET High absorbance quick dry filament fabric treated with and endothermic cooling agent. It was possible to develop a functional coolness fabric with a cool-touch and a cool-absorbent when the content of triacetate and cover factor were well combined.

A Study on the Korean Ondol-System Application in Apartment Houses (공동주택의 한국형 온돌시스템 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF

Development of IR Reflective Cool Pigment and Paint (차열도료용 Cool Pigment 및 Paint 개발)

  • Kwon, Myon-Joo;Do, Young-Woong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3800-3805
    • /
    • 2012
  • Infrared(IR) reflective black cool pigment and paint which is used for interior/exterior materials(IR reflectance >30%) to prevent heat island effect and to increase energy efficiency were studied. Cool pigment was synthesized using mixture of $Fe_2O_3$ and $Cr_2O_3$ with calcination from 900 to $1,200^{\circ}C$. Cool paint was prepared by formulation of cool pigment, acrylic resins, and other additives. Results showed that optimum color fixation of pigment obtained by mole ratio of Fe to Cr was 0.9 with calcination temperature at $1,000^{\circ}C$. The cool paint formulated by 20% pigment and 1.5% dispersive additive with $125{\mu}m$ thickness of coated layer showed optimum IR reflectance. Temperature difference on surface between cool paint and ordinary paint(STD) was $36.5^{\circ}C$ and IR reflectance(TSR) was 39.3% at wavelength from 700 to 2,500nm. And color change was not detected during 500hrs weathering test.

HYDROGEN EMISSION SPECTRA OF QUIESCENT PROMINENCES

  • Kim, Kap-Sung
    • Journal of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.71-82
    • /
    • 1990
  • Theoretical calculations of the combined radiative transfer and statistical equilibrium equation including the charge-particle conservations have been earned out for a multilevel hydrogen atom in quiescent prominences. Cool and dense models show the steep changes of population and radiation field in the vicinity of the surface, while these physical quantities remain unchanged for models with temperature of 7,300K, regardless of total densities. Ionization rate of hydrogen atom related with metallic line formation varies in considerable amounts from the surface to the center of model prominences cooler than 6,300K. However, such cool models cannot release enough hydrogen line emissions to explain observed intensities. Prominence models with a temperature higher than 8,000K can yield the centrally reversed Lyman line profiles confirmed by satellite EUV observations. We find that queiscent prominence with a density between $2{\times}10^{11}$ and $10^{12}cm^{-3}$ should be in temperature range between 6,300K and 8,300K, in order to explain consistently observed H alpha, beta line emissions and $n_p/n_l$ ratio.

  • PDF

Heat Mitigation Effects of Urban Space based on the Characteristics of Parks and their Surrounding Environment (도시공원 및 주변환경의 특성이 도시공간의 온도저감에 미치는 영향)

  • Suh, Jung-Eun;Oh, Kyu-Shik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.1-14
    • /
    • 2020
  • In order to improve the urban thermal environment, efforts are being made to increase green areas in cities that include park construction, planting, and green roofing. Among these efforts, urban parks play an important role not only in improving the urban thermal environment, but also in terms of ecosystem services (serving as resting places for citizens, providing cleaner air quality, reducing noise, etc.). Therefore, the purpose of this study is to suggest planning and management guidelines for urban parks that are effective in improving the thermal environment, by analyzing the urban surface temperature reduction performance of urban parks. To do this, first, land surface temperature was calculated by using Landsat 8 images. Second, the PCI (Park Cool Island) index was calculated to identify the temperature reduction performance of urban parks. Third, the characteristics of parks (area, shape, vegetation) and the surrounding spatial characteristics (land cover, building-related variables, etc.) were identified. Finally, the relationship between the PCI indices (PCI scale, PCI effect, PCI intensity) and the characteristics of the parks and their surroundings were analyzed. The results revealed that the parks consisting of a larger area, simple shape, and higher tree coverage ratio had increased PCI performance, and were advantageous for improving the urban thermal environment. Meanwhile, PCI performance was found to have decreased in areas with a higher impermeable area ratio and building coverage ratio. The outcomes of this study can be used to identify priority areas for planning and management of urban parks and can also be utilized as planning and management guidelines for improving urban thermal environment.

Laboratory and Field Performance Evaluation of Acryl Resin Based Solar Radiation Reflective Pavement (아크릴 수지를 이용한 차열성 포장의 실내 및 현장 공용성 평가)

  • So, Kyung-Rock;Lee, Hyun-Jong;Baek, Jong-Eun;Lee, Sang-Yum
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.19-28
    • /
    • 2011
  • This study developed a solar radiation reflection pavement, so called a cool pavement, to lessen the urban heat island effect by coating a pavement surface with acrylic resins mixed with light-colored pigments. From a laboratory test, simulating solar heating process in pavements, the cool pavement reduced more than $12^{\circ}C$ of pavement temperature at $60^{\circ}C$ compared to a control porous pavement. With the increase of the mixing ratio of the pigments to acrylic resins, the temperature reduction effect increased, but its workability became worse due to higher viscosity. As a result, an appropriate mixing ratio was determined as 15%. The cool pavement had better durability than the control pavement: One quarter of Catabro loss and twofold dynamic stability. Its adhesion was also higher enough not to be debonded under traffic loading. In-situ noise and friction tests conducted in two field sites showed that the cool pavement reduced its noise level by 3.7dB in average and increased its friction level by 30% compared to the control pavement. The permeability of the cool pavement was little lower than the control pavement, but higher enough to satisfy the minimum requirement for porous pavements.

THE SURFACE DISTRIBUTION OF CARBON STARS IN THE GALAXY

  • KURTANIDZE OMAR M.;NIKOLASHVILI MARIA G.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.129-131
    • /
    • 1996
  • The results on the deep low dispersion (1250 ${\AA}$/mm at $H_r, $30^{\circ}$ < I < $165^{\circ}$, $195^{\circ}$ < I < $210^{\circ}$, [b] < $5^{\circ}$; 7000${\AA}$/mm at A band, $50^{\circ}$ < I < $115^{\circ}$, b=$0^{\circ}$, b=${\pm}3.5^{\circ}$) spectral surveys of the MILKY WAY are presented. More than 2250 carbon stars were identified among them 1440 new ones. The C/M5+ ratio increases from 0.02 to 0.3 when longitude varies from $30^{\circ}$ to $210^{\circ}$. On the basis of A GENERAL CATALOG OF GALACTIC COOL CARBON STARS the surface distribution of carbon stars has been studied.

  • PDF

Shape Control and Characterization of One-dimensional ZnO Nanostructures through the Synthesis Procedure (합성절차에 따른 1차원 ZnO 나노구조의 형태조절과 특성평가)

  • Kong, Bo-Hyun;Park, Tae-Eun;Cho, Hyung-Koun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.13-17
    • /
    • 2006
  • The one-dimensional ZnO nanostructures prepared through thermal evaporation under various cooling down procedures by changing the flow rates of the carrier gas and the reactive gas were investigated. The nanorod structures were changed into the nanonail types with a broad head through the reduction of the flow rate of the carrier gas. The decrease of the reactive gas reduced the length of the nail heads due to the limited mass transport of reactive gas. The intensity ratio of the ultraviolet emission/green emission of photoluminescence was proportional to the length of the broad head showing a larger surface area. The vertically aligned nanostructures were grown along the [0001] direction of ZnO regardless of the aligned directions. The crystal direction of the nanostructures was determined by that of the initial ZnO crystal.