• Title/Summary/Keyword: Cool Water

Search Result 222, Processing Time 0.022 seconds

Recent Vegetation History and Environmental Changes in Wangdeungjae Moor of Mt. Jiri

  • Kim, Jae-Geun;Lee, Yang-Woo
    • The Korean Journal of Ecology
    • /
    • v.28 no.3
    • /
    • pp.121-127
    • /
    • 2005
  • To reveal vegetation history and environmental changes in Mt. Jiri, sediment cores were collected from Wangdeungjae moor of Mt. Jiri. Overall dry matter accumulation rates and sedimentation rates by $^{14}C-dating$ were 0.027 $kg{\cdot}m^{-2}{\cdot}yr^{-1}$ and 0.184 mm/yr since 1250 ($760{\pm}40$ yrs BP, 14 cm in depth). There are three pollen zones; the first zone is below 14 cm depth where Quercus dominated, the second zone is from 14 cm to 6 cm depth where Gramineae increased and Quercus and Salix dominated and the third zone is from 6 cm depth to the top where Pinus and Quercus dominated. Total pollen concentration gradually increased from bottom to the top of sediment core, which implies wet, anaerobic and cool condition during covered period by the core. Calcium and magnesium contents had increased since 14 cm depth, with peaks at 13 and 20 cm depths. This indicates that groundwater had recently become relatively more important than surface water as water source of Wangdeungjae moor Exotic plant or Chenopodiacea pollen was less than 1%. There was little variation in total N and P contents along the length of the core. These results support that Wangdeungjae moor has been little affected by anthropogenic activities. Also, nutrients and heavy metal contents indicate the baseline condition of Wangdeungjae moor.

A Study On Heat Transfer and Flow Characteristics for Boring in Sewer by Rotating Cutter Tool (회전노즐장비 작동시 하수관내의 열전달 및 유동현상에 관한 연구)

  • Park Young-Ki;Lee Jang-Choon;Lee Dong-Joo
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.95-100
    • /
    • 2006
  • Heat transfer and flow characteristics in a pipe in which the rotating cutting tool for boring a underground pipe without digging were considered in this study. The amount of heat generation due to the friction between the rotating cutter and pipe wall, mixing (low of air and water injected to cool down are the two important factors to design the boring machine Computational fluid dynamics analysis using the Eulerian mixture model and the standard $\kappa-\varepsilon$ turbulence model was used to analyze the complex phenomena in a pipe during the process. Results show that pipe wall temperature decreased with increasing the cooling water inlet velocity. it is also shown that pipe wail temperature was lowered when the cutter rotation speed was increased until 600 rpm. There was no further cooling effect over 600 rpm.

Changes in Pectic Substances of Korean Pickled Cucumbers with Different Preparation Methods (담금 방법을 달리한 오이지의 숙성 중 펙틴질의 변화)

  • 장명숙;박미원;박용곤
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.1
    • /
    • pp.133-140
    • /
    • 1995
  • This investigation was undertaken for the purpose of studying the changes of pectic substances in alcohol insoluble solids(AIS) extracted from cucumbers pickled in salt. The preparation methods were brining the cucumbers in 10% NaCl solution (bolied, method A), 20% NaCl solution(bolied, method B) and 20% NaCl solution(cool to $25^{\circ}C$ after boiling, method C). The composition ratio of hot water soluble pectin(HWSP) in AIS decreased during brining, while that of 0.4% sodium hexametaphosphate soluble pectin(NaSP) increased remarkably. The contents of Ca and Mg in AIS increased regardless of preparation methods used. By DEAE-cellulose chromatography, HWSP from fresh and brined cucumbers were divided into six fracitons. 0.2M peak was the main fraction in fresh cucumber, whereas 0.05M and 0.2M peak were the main fraction in pickled cucumbers. On the other hands, NaSP from fresh and brined cucumbers were divided into five fractions and 0.4M peak was the main fraction. However, the composition ratios of galacturonic acid and neutral sugar of 0.4M fraction in brined cucumbers were higher than those of fresh cucumber.

  • PDF

Experimental validation of the seismic analysis methodology for free-standing spent fuel racks

  • Merino, Alberto Gonzalez;Pena, Luis Costas de la;Gonzalez, Arturo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.884-893
    • /
    • 2019
  • Spent fuel racks are steel structures used in the storage of the spent fuel removed from the nuclear power reactor. Rack units are submerged in the depths of the spent fuel pool to keep the fuel cool. Their free-standing design isolates their bases from the pool floor reducing structural stresses in case of seismic event. However, these singular features complicate their seismic analysis which involves a transient dynamic response with geometrical nonlinearities and fluid-structure interactions. An accurate estimation of the response is essential to achieve a safe pool layout and a reliable structural design. An analysis methodology based on the hydrodynamic mass concept and implicit integration algorithms was developed ad-hoc, but some dispersion of results still remains. In order to validate the analysis methodology, vibration tests are carried out on a reduced scale mock-up of a 2-rack system. The two rack mockups are submerged in free-standing conditions inside a rigid pool tank loaded with fake fuel assemblies and subjected to accelerations on a unidirectional shaking table. This article compares the experimental data with the numerical outputs of a finite element model built in ANSYS Mechanical. The in-phase motion of both units is highlighted and the water coupling effect is detailed. Results show a good agreement validating the methodology.

An Overview of Teff (Eragrostis teff Zuccagni) Trotter) as a Potential Summer Forage Crop in Temperate Systems

  • Habte, Ermias;Muktar, Meki S.;Negawo, Alemayehu T.;Lee, Sang-Hoon;Lee, Ki-Won;Jones, Chris S.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.3
    • /
    • pp.185-188
    • /
    • 2019
  • The production of traditional cool season grasses in temperate regions is becoming hampered during summer seasons due to water deficit. Thus, incorporating water use efficient warm season annual grasses are generally considered to fill the gap of summer season forage reduction that would offer considerable flexibility and adaptability to respond to forage demand. Teff (Eragrostis teff Zuccagni) Trotter) is, a C4 drought tolerant warm season annual grass primarily grown for grain production, recently gaining interest for forage production particularly during summer season. Previous reports have showed that teff is palatable and has comparable forage biomass and feed quality as compared to other warm season annual grasses which would make it an alternative forage. However, the available data are not comprehensive to explore the potential of teff as forage, hence further assessment of genotype variability and performance along with compatibility study of teff with forage production system of specific environment is key for future utilization.

Development of risk assessment framework and the case study for a spent fuel pool of a nuclear power plant

  • Choi, Jintae;Seok, Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1127-1133
    • /
    • 2021
  • A Spent Fuel Pool (SFP) is designed to store spent fuel assemblies in the pool. And, a SFP cooling and cleanup system cools the SFP coolant through a heat exchanger which exchanges heat with component cooling water. If the cooling system fails or interfacing pipe (e.g., suction or discharge pipe) breaks, the cooling function may be lost, probably leading to fuel damage. In order to prevent such an incident, it is required to properly cool the spent fuel assemblies in the SFP by either recovering the cooling system or injecting water into the SFP. Probabilistic safety assessment (PSA) is a good tool to assess the SFP risk when an initiating event for the SFP occurs. Since PSA has been focused on reactor-side so far, it is required to study on the framework of PSA approach for SFP and identify the key factors in terms of fuel damage frequency (FDF) through a case study. In this study, therefore, a case study of SFP-PSA on the basis of design information of APR-1400 has been conducted quantitatively, and several sensitivity analyses have been conducted to understand the impact of the key factors on FDF.

Uncharted Diversity and Ecology of Saprolegniaceae (Oomycota) in Freshwater Environments

  • Bora Nam;Thuong T. T. Nguyen;Hyang Burm Lee;Sang Kyu Park;Young-Joon Choi
    • Mycobiology
    • /
    • v.50 no.5
    • /
    • pp.326-344
    • /
    • 2022
  • The fungal-like family Saprolegniaceae (Oomycota), also called "water mold," includes mostly aquatic saprophytes as well as notorious aquatic animal pathogens. Most studies on Saprolegniaceae have been biased toward pathogenic species that are important to aquaculture rather than saprotrophic species, despite the latter's crucial roles in carbon cycling of freshwater ecosystems. Few attempts have been made to study the diversity and ecology of Saprolegniaceae; thus, their ecological role is not well-known. During a survey of oomycetes between 2016 and 2021, we investigated the diversity and distribution of culturable Saprolegniaceae species in freshwater ecosystems of Korea. In the present study, members of Saprolegniaceae were isolated and identified at species level based on their cultural, morphological, and molecular phylogenetic analyses. Furthermore, substrate preference and seasonal dynamics for each were examined. Most of the species were previously reported as animal pathogens; however, in the present study, they were often isolated from other freshwater substrates, such as plant debris, algae, water, and soil sediment. The relative abundance of Saprolegniaceae was higher in the cold to cool season than that in the warm to hot season of Korea. This study enhances our understanding of the diversity and ecological attributes of Saprolegniaceae in freshwater ecosystems.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Isolation of the Legionella Species from Specimens of Cooling Tower Water (환경수(냉각탑수)로 부터 Legionella속 균의 분리)

  • Chung, Jong-Hak;Kang, Pock-Soo;Kim, Seok-Bhum;SaKong, Jun
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.77-84
    • /
    • 1988
  • The principal mode of the transmission of Legionnaires disease is a inthalation of the cooling tower water droplets in which Legionellae exist. As a central cooling system is popularized in many public buildings and large buildings nowadays, the number of cooling towers is rapidly increasing. Therefore the possibility of an outbreak of Legionnaires disease is likely increased. To determine the presence of Legionella in cooling tower water as the first step for the prevention of Legionnaires disease, 48 samples of cooling tower water were taken from 24 buildings in Taegu city in july and september 1987. Three samples out of 24 water samples In September yielded Legionella but it was not isolated in the samples of July. Isolated 3 Legionellas were identified as Legionella peumophila. It seems that Legionella from the cooling tower will be isolated more frequently in late summer than early because central cooling system is stopped operation during winter season which is cool. As based on our survey, Legionnaires disease can occur in Taegu city and if it happens it is most likely due to L. pneumophila.

  • PDF

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.