• 제목/요약/키워드: Cool

검색결과 1,543건 처리시간 0.029초

신량해표(辛凉解表)의 역사와 의미에 대한 고찰 (A Study on the History and Meaning of Exterior Relief Methods using Pungent-cool Properties)

  • 윤기령;백유상;장우창;정창현
    • 대한한의학원전학회지
    • /
    • 제33권1호
    • /
    • pp.149-158
    • /
    • 2020
  • Objectives : This study aims to examine the exterior relief method through pungent-cool properties in comparison to pungent-warm properties historically, to understand the meaning of 'exterior relief through pungent-cool' more thoroughly. Methods : Contents mentioning the treatment method directly were examined historically, then analyzed. Results & Conclusions : The method to relieve the exterior through pungent-cool properties has developed by overcoming the limitations of the method to relieve the exterior through pungent-warm properties since it was first established in 『Shanghanzabinglun』(『傷寒雜病論』). The term 'relief of the exterior through pungent-coolness'(辛凉解表) was first mentioned in the Ming period, referring to weak level of perspiration. Yetianshi(葉天士) explained it as communicating Weiqi(衛氣) using pungent-cool medicinals for heat to discharge through the exterior, resulting in mild sweating. In 『Wenbingtiaobian』(『溫病條辨』) the term 'to relieve the flesh'(解肌) refers to both mild sweating through pungent-warm medicinals and the opening of the exterior through pungent-cool medicinals for pathogenic qi to exit, resulting in sweating. If the exterior relief of the pungent-warm medicinals happens through the warm Yang qi(陽氣) stimulated the inner Yin fluids(陰液) to discharge as sweat, that through pungent-cool medicinals relieves stagnation in the exterior, opening up a way for the pathogenic heat to exit. From the perspective of the main therapeutic mechanism for pungent-cool medicinals to be its coolness relieving heat, the term 'exterior relief through pungent-coolness' becomes erroneous. For the 'exterior relief through pungent-coolness' category to be valid, the meaning of 'exterior relief' needs to be expanded to include not only stimulated sweating but the treatment process that could result in sweating.

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

여름철 냉감성 의류소재 개발을 위한 비스코스 레이온 중심의 직물 제조 및 PCM 가공 (Preparation of Rayon Filament based Woven Fabric and PCM Treatment for Developing Cool Touch Summer Clothing Material)

  • 홍경화
    • 한국의류산업학회지
    • /
    • 제16권2호
    • /
    • pp.326-332
    • /
    • 2014
  • To develop cool touch feeling fabrics for summer clothing material, it was manufactured several compositions of woven fabrics, having rayon multi-filament yarn (non-twisted) as warp and various kinds of yarn, such as viscose rayon multi-filament yarn (twisted), tencel$^{(R)}$ spun yarn, PET high absorbance quick dry filament yarn, and PET based rayon-like yarn, as weft. After preparing the fabrics, basic properties of the fabrics were investigated, such as air-permeability, tensile strength, absorption rate, drying rate, etc. Also, surface warm / cool sensations of the woven fabrics were assessed by Qmax Warm / Cool Touch Tester. It was observed that the fabrics composed of viscose rayon multi-filament yarn (warp) and PET high absorbance quick dry filament yarn (weft) showed excellent surface cool touch sensation-the highest Qmax value. This is because the fabric having flat shaped PET high absorbance quick dry filament shows the largest contact area with Qmax measuring plate. And, the fabric also showed superior high absorbance and quick dry property as expected. In addition, we treated phase change material (PCM) on the surface of the fabric composed of viscose rayon multi-filament yarn (warp) and PET high absorbance quick dry filament yarn(weft) to improve the cool touch feeling. However, the surface cool touch feeling was impaired by resin treated with PCM during the finishing process.

면직물의 구성특성과 냉온감과의 상관성에 관한 연구( I ) -상대습도 $65\%$하에서- (A Study on the Relationship between Structural Characteristics of Cotton Fabrics and their Cool-and-Warm Felling (I) - at $65\%$ Relative Humidity-)

  • 장지혜
    • 한국의류학회지
    • /
    • 제14권2호
    • /
    • pp.152-163
    • /
    • 1990
  • The purpose of this study is to experimentally analyze the relationship between structural characteristics of cotton fabrics and their cool-and-warm felling in order to develop more comfortable fabrics. Comfort in textile products has been emphasized as consumers preferred performance to fashion of clothing. Thermal comfort of clothing is a basic parameter of the comfort sensation which is usually represented by the cool-and-warm feeling felt by human skin. Cloo-and-warm feeling is perceived by the heat flux which transfers heat energy stored in an object to skin. We feel warm (cool) if the temperature of nerve extremity in skin ascends (descends). As cool-and-warm feeling determines the comfort sensation of clothing, it is important to develop new comfort fabrics. Although considerable works have been made on the body, clothing, and environment, there has been no research study on the structural characteristics of fabrics and their cool and warm feeling. Cool-and-warm feeling is closely related to the transient heat transfer property. This research study used the cotton fabrics manufactured in Korea as sample and measured $q_{max}$ value with thermal property measuring instrument (Thermo-Labo II type). $q_{max}$ values estimated by polynomial regression equation were compared with those observed in this study. This study also identified the structural parameters of cotton fabrics for a specific range of $q_{max}$ values. The findings of this study can be summarized as follows: 1) As the thickness, porosity and air permeability of cotton fabrics increase, $q_{max}$ value decreases. 2) As the fabric count and over factor of cotton fabrics increase, $q_{max}$ value also increases. 3) $q_{max}$ values have been estimated by simple and polynomial regression equations developed in this study. Regression curves which have been plotted by polynomial regression equations also provided with the range of structural parameters for a specific range of $q_{max}$ values of cotton fabrics. This study would be significant in that it has identified the structural Parameters for the cool-and-warm feeling of cotton fabric at $65\%$ relative humidity.

  • PDF

대외무역법 원산지표시위반 관련 벌칙에 관한 연구 (A Study on the Penalty of the Breach of Country of Origin Labeling in Korea Foreign Trade Act)

  • 박광서
    • 무역상무연구
    • /
    • 제47권
    • /
    • pp.379-402
    • /
    • 2010
  • The Korea Foreign Trade Act(KFTA) was revised the penal provisions of the breach of the Country of Origin Labeling(COOL) recently. The ceiling of penalties became to 5 years for imprisonment, one hundred or three hundred million won for fine. The level of penalties are adjudged quite fair but the amount of penalty should be increased according to the profits from the breach or the nature of crime in some cases. The problems of the penalties are differences between KFTA and other related laws. There are related several laws on the breach of the COOL such as KFTA, Unfair Trade related Law, Customs Law, Consumer Protection Law, Law of COOL on Agricultural and Marine products etc. The penal provisions of the breach of the COOL has more heavier level than other the breach because of the criminal qualities. The problems are the penalty differences between the KFTA and the Unfair Trade Law under the Ministry of Knowledge Economy. The KFTA's penal provisions need to equate with Unfair Trade Law as long as same breaches on the COOL. The government can also consider some policies to rigid enforcement of breaches on the COOL. There are the Country of Origin Tracking system, the RoO Paparazzi System, Make public the names of habitual RoO Violators, Correction Order of breach of the COOL etc.

  • PDF

급냉각기간에서 멤브레인형 LNGC의 분무냉각 열해석에 관한 연구 (A Study on the Thermal Analysis of Spray Cooling for the Membrane Type LNGC During the Cool-Down Period)

  • 이정혜;김경근;노승탁;정한식;김성규
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.125-134
    • /
    • 2003
  • The present paper is concerned to the thermal analysis during the cool-down period of 138,000 m$^3$class GTT MARK-III membrane type LNG carrier servicing with LNG from the Middle East to Korea. It is the cool-down period that cools the insulation wall and the gas in LNG tank to avoid the thermal shock as the start of loading of -162$^{\circ}C$ LNG. For six hours of the standard cool-down period, the temperature of NG falls down from -4$0^{\circ}C$ to -13$0^{\circ}C$ and especially the mean temperature of the 1st barrier in the top side insulation wall falls down from -38.38$^{\circ}C$ to -122.42$^{\circ}C$ in case of IMO design condition. By the 3-D numerical calculation about the cargo tank and the cofferdam, the temperature variation in hulls and insulations is precisely predicted in this paper. And the mean temperature variation of gas is calculated as the function of the spraying rate by the heat balance model during the cool-down period.

Cool Tube System 사례를 활용한 환기부하 절감방안 (Ventilation Load Reduction Plan Using Cool Tube System Case)

  • 정민영;박진철;양영권
    • 토지주택연구
    • /
    • 제10권1호
    • /
    • pp.25-32
    • /
    • 2019
  • In this study, the case analysis data on underground temperature are presented. In addition, numerical analysis of the ventilation load reduction plan was derived according to the residence schedule change for the building with cool tube. The research scope and method are as follows. The overall system principle was examined through reviewing the theory of the Cool tube system. Case study and analysis were conducted. Numerical simulation was used to examine the change in energy usage. Also, the change of load energy in case of varying amount of ventilation was derived based on actual building room schedule. When the Cool tube system was applied to the residential buildings, the cooling load was reduced from 3,331 kW to 193 kW, which showed a reduction effect of about 90%.The heating load was reduced from 42,276kW to 32,575kW by 23%.Also, result shows that the cooling load decreased by 24% and the heating load decreased by 66% when the number of ventilation according to the occupancy schedule was applied.

The milli-arcsecond scale radio properties of central AGNs in cool-core and non cool-core clusters

  • Baek, Junhyun;Chung, Aeree;Tremou, Evangelia;Sohn, Bongwon;Jung, Taehyun;Ro, Hyunwook
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.68.4-69
    • /
    • 2016
  • We report preliminary results of KaVA observations of central galaxies in cool-core and non cool-core clusters. The main goal is to study how cooling environments of galaxy clusters affect the central AGN activities especially at its innermost region. For KaVA observations, 7 radio bright AGNs have been selected from the extended Highest Flux Galaxy Cluster Sample (eHIFLUGCS; the X-ray flux limited & all sky galaxy cluster catalog) with various cooling timescales. In our previous KVN study, we have found that most AGNs in the cool-core clusters show the hint of pc-scale jet-like features while the ones in the non cool-core clusters do not. Using the KaVA 22/43 GHz data of a much higher resolution than the KVN resolution, we have investigated detailed pc-scale jet properties such as physical size, morphology, and radiative age. Based on the KaVA data, we discuss the effect of cluster cooling environment on the evolution of AGNs in the cluster center.

  • PDF

Chandra Archival Survey of Galaxy Clusters: X-ray Point Sources in Cool-core and Non-cool-core Clusters

  • 김민선;김은혁
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.78.1-78.1
    • /
    • 2012
  • We have studied the physical properties of X-ray point sources in galaxy clusters using ~600 Chandra archival observations. The goal of this study is to investigate the density environmental effects on the physical properties of X-ray point sources by comparing the properties of X-ray point sources in galaxy clusters to those in typical blank fields. In this presentation, we show the nature of X-ray point sources which are expected to be related with galaxy clusters with different core properties. Using ~60 galaxy clusters observed with Chandra, we investigate the physical properties of X-ray point sources in cool-core and non-cool-core clusters. The cool-core clusters are known to have short central cooling time, and are characterized by low central entropy, systematic central temperature drops, and a brightest cluster galaxy at the X-ray peak. While the non-cool-core clusters have longer central cooling time, and are characterized by large central entropies and flat or centrally rising temperature profile. We show that how central core properties of galaxy clusters affect on the physical properties of X-ray point sources.

  • PDF

공동주택의 한국형 온돌시스템 적용에 관한 연구 (A Study on the Korean Ondol-System Application in Apartment Houses)

  • 안민희;최창호;유기형;조동우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF