• Title/Summary/Keyword: Convex probe

Search Result 28, Processing Time 0.028 seconds

Identification of High Frequency Peakers with long-term monitoring observation at 22 and 43 GHz

  • Jeong, Yongjin;Sohn, Bong Won;Chung, Aeree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.68.2-68.2
    • /
    • 2014
  • High Frequency Peakers (HFPs) are radio-loud Active Galactic Nuclei (AGN), which are regarded as being in the earliest evolutionary phase (102-103 years) of radio galaxies. They are expected to be small in size (< ~1 kpc) compared to their host galaxies (~a few 10s kpc), and have convex spectra, which are peaking at high radio frequency (> 5 GHz). Their size and spectral shape are the most obvious supporting evidence of extremely young ages. HFPs are therefore ideal targets to probe the earliest stage of radio sources. To date however, the young radio source classification has been relying mainly on the spectral shape which usually does not cover high enough frequencies where the true peak flux is located. Hence HFPs are often confused with blazars which may show a similar spectral shape and apparent compactness but are a somewhat evolved form of AGNs. Therefore, we have been challenging to identify HFPs among the sample of 19 candidates using the Korean VLBI Network (KVN) which enables us to extend the radio spectrum baseline up to 22 and 43 GHz. These are higher than the frequencies used in most previous studies of HFPs, allowing us to select genuine HFPs. By long-term monitoring of 18 epochs, we have also inspected the variability of the sample to select out blazars which are highly variable yet with a similar radio spectrum. In this work, we present the light curves and spectral properties of the HFP candidates. We discuss the results of our re-identification of HFPs.

  • PDF

The Effect of Pelvic Floor Muscle Contraction with Image Feedback on Abdominal Muscle Thickness (영상피드백을 적용한 골반저근 수축이 복부 근 두께에 미치는 영향)

  • Kim, Jin-Hee;Kim, Nan-Soo;Jang, Jun-Hyeok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.4
    • /
    • pp.533-539
    • /
    • 2012
  • PURPOSE: The purpose of this study was to investigate the effect of pelvic floor muscle contraction with image feedback on Abdominal muscle thickness. METHODS: Twenty three adults participated in this study. Abdominal muscle thickness was measured by ultrasound in three condition(rest, pelvic floor muscle contraction, pelvic floor muscle contraction with image feedback). Subjects was contraction pelvic floor muscle by general method. And ultrasound(convex probe, 3.5MHz) was used to image feedback for selective pelvic floor muscle contraction. One-way ANOVA was used to compare abdominal muscle thickness in three condition. RESULTS: There was no significant difference in external oblique(p=.514) and internal oblique muscle(p=.250) thickness by three condition. There was significant difference in transverse abdominis thickness by three condition (Transverse abdominis thickness was highest while Pelvic floor muscle contraction than pelvic floor muscle contraction with image feedback and rest.)(p=.000). CONCLUSION: This study shows that pelvic floor muscle contraction with image feedback increase the thickness of transverse abdominis lesser than general pelvic floor muscle contraction.

Growth and Characterization of Graphene Controlled by Cooling Profile Using Near IR CVD

  • Park, Yun-Jae;Im, Yeong-Jin;Kim, Jin-Hwan;Choe, Hyeon-Gwang;Jeon, Min-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.207-207
    • /
    • 2013
  • 기존의 그래핀 성장에 관한 연구는 열화학기상증착법(Chemical vapor deposition; CVD)을 이용한다. 그래핀 성장 제어 요소로는 촉매 기판인 전이 금속[Ru, Ir, Co, Re, Pt, Pd, Ni, Cu], 기판 전처리 과정, 수소/메탄 가스 혼합비, 작업 진공 상태, 기판온도[$800{\sim}1,000^{\circ}C$, 냉각 속도 등으로 보고 되고 있다. 그래핀 성장 원리는 Cu 촉매 기판에 메탄 가스를 $1,000^{\circ}C$ 온도에서 분해해서 탄소를 고용 시킨 후 급랭하는 도중에 석출되는 탄소에 의해 그래핀 시트가 형성되는 것으로 알려져 있다. 기존의 CVD를 열원을 이용할 경우 내부 챔버에 생기는 잠열에 의해 cooling profile의 제어가 용이하지 않다. 본 연구에서는 근적외선(Near Infrared; NIR) 열원을 이용한 CVD로 챔버 내부 잠열을 최소화하고, 냉각 공정을 Natural, Linear, Convex cooling type으로 디자인해서 cooling profile 제어가 그래핀 성장에 미치는 영향을 연구 하였다. 이렇게 성장된 그래핀을 임의의 기판(SiO2, Glass, PET film) 위에 습식방법으로 전이 시킨 후, 전기적 구조적 및 광학적 특성을 면저항(four-point probe), 전계방사 주사전자현미경(Field Emission Scanning Electron Microscope; FE-SEM), 마이크로 라만 분광법(Micro Raman spectroscopy) 및 광학현미경(optical microscope), 투과도(UV/Vis spectrometer)의 측정으로 잠열이 최소화된 NIR-CVD에서 cooling profile에 따른 그래핀 성장을 평가하였다.

  • PDF

An Optical Surfacing Technique of the Best-fitted Spherical Surface of the Large Optics Mirror with Ultra Precision Polishing Machine (대형 광학계 연마 장비에 의한 대구경 반사경의 최적 근사 구면 제조 방법에 관한 연구)

  • Song, Chang Kyu;Khim, Gyungho;Hwang, Jooho;Kim, Byung Sub;Park, Chun Hong;Lee, Hocheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.324-330
    • /
    • 2013
  • This paper describes a novel method to surface large optics mirror with an extremely high hardness, which could replace the high cost of the repetitive off-line measurement steps and the large ultra-precision grinding machine with ultra-positioning control of 10 nm resolution. A lot of diamond pellet to be attached on the convex aluminum base consists of a grinding tool for the concave large mirror, and the tool was pressured down on the large mirror blank. The tool motion at an interval on the spiral path was controlled with each feed rate as the dwell time in the conventional computer-controlled polishing. The shape to be surfaced was measured directly by a touch probe on the machine without any separation of the mirror blank. Total 40 iterative steps of the surfacing and measurement could demonstrate the form error of RMS $7.8{\mu}m$, surface roughness of Ra $0.2{\mu}m$ for the mirror blank with diameter of 1 m and spherical radius of curvature of 5400 mm.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

Superovulation Response after Follicular Wave Synchronization with Follicular Aspiration by Ultrasonography in HanWoo I. Effect of Follicular Aspiration on Ovarian Response Following Superovulation (과배란 처치시 우세난포 조절에 의한 한우 수정란 생산성 향상에 관한 연구 I. 우세난포 처리에 따른 난소반응)

  • 이병천;이동원;신수정;박종임;황우석
    • Journal of Embryo Transfer
    • /
    • v.14 no.3
    • /
    • pp.203-210
    • /
    • 1999
  • In this stuyd, the effect of the dominant follicle aspiration for the superovulatory response in HanWoo was investigated. The criterion for the presence or absence of a dominant follicle based on their morphological examination. The dominant follicle was aspirated 48hr before the onset of superovulation treatment by 6.5MHz convex probe connected with a carrier and superovulation induced by FSH (Super-Ov Tyrer, Texas, U.S.A) adminstered twic a day s.c. over 4 day in a decreasing regimen. From 13 HanWoo scanned daily to determine the presence and growth of the dominant follicle, its an average diameter of 15.4mm was measured and an average diameter of corpora lutea was 18.7mm on day of follicular aspiration. In the experiment, a follicular remove by ultrasound-guided aspiration, the ovarian response was significantly enhanced when animals were superovulated in the aspiation of a dominant follicle compare with animals superovulated non-aspiration of a dominat follicle. In the aspiration of a dominant follicle donors yieleded more corpora lutea(14.4$\pm$4.7 vs 8.6$\pm$3.4) and transferable embryos(8.9$\pm$4.2 vs 5.4$\pm$2.7) than control. In cows in which the dominant follicle had been aspirated under sonographical control 2 days before superovuation, the number of corpus lutea and transferable embryos were significantly enhanced compared with animals superovulated in the presence of a dominant follicle (14.4$\pm$4.7 vs 6.9$\pm$2.7, ; 8.9$\pm$4.2 vs 3.3$\pm$1.6). After 7 days of artificial insemination, the embryos at 7 days were cllected by uterine flushing after dominant follicle insemination, the embryos at 7 days were collected by uterine flushing after dominant follicle aspiration and superovulation treatment, and evaluated their quality by morphological criteria. Sixteen embryos with excellent and good grade were transferred into 8 recipient cows. Six pregnancies were identified at 60 and 120 days of gestation by rectal palpations. In conclusion, the present study showed that 1) the presence or absence of a dominant follicle signficicnatly affects superovulatory responses, and 2) ultrasound-guided follicular aspiration of the dominant follicle and superovuation treatment provides an accurate and procedure to increase ovarian responses in HanWoo.

  • PDF

Effect of Chlorhexidine Mouthrinse on Prevention of Microbial Contamination during EBUS-TBNA: A Study Protocol for a Randomized Controlled Trial

  • Kim, Na Young;Park, Jae Hyeon;Park, Jimyung;Kwak, Nakwon;Choi, Sun Mi;Park, Young Sik;Lee, Chang-Hoon;Cho, Jaeyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard diagnostic method for mediastinal and hilar lymphadenopathy. Although rare, fatal infectious complications can occur following EBUS-TBNA. However, to date, there is a lack of effective preventive strategies to reduce these complications. We started a trial to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Methods: This study is a single-center, parallel-group, assessor-blinded randomized controlled trial (RCT). We will enroll 112 adult participants undergoing EBUS-TBNA using a convex probe, and randomly assign them to two groups at a 1:1 ratio. The intervention group will gargle for 1 minute with 100 mL of 0.12% chlorhexidine gluconate before EBUS-TBNA, while the control group will have no mouthrinse before the procedure. Immediately after completion of EBUS-TBNA on all targeted lesions with an aspiration needle, a needle wash sample will be taken by instilling 5 mL of sterile saline into the used needle. The primary outcome is colony forming unit (CFU) counts in aerobic cultures of the needle wash samples. Secondary outcomes are CFU counts in anaerobic cultures, fever within 24 hours after EBUS-TBNA, and infectious complications within 4 weeks after EBUS-TBNA. Conclusion: This trial was designed as the first RCT to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Results from this trial can provide clinical evidence for a simple, safe, and cost-effective strategy to prevent infectious complications following EBUS-TBNA (ClinicalTrials.gov ID: NCT04718922, registered on 22 January 2021).

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.