• Title/Summary/Keyword: Convex probe

Search Result 28, Processing Time 0.019 seconds

Design and Fabrication of a 3-dimensional Diagnostic Ultrasonic Probe (3차원 입체 영상 진단용 초음파 프로브의 설계 및 제작)

  • Eun, Hong;Lee, Su-Sung;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.766-771
    • /
    • 2002
  • In this study, we have developed a 3-dimensional diagnostic ultrasonic sector probe using a convex type ultrasonic probe with 128 active elements. The probe was made to operate at the center frequency of 4.5㎒ with the bandwidth of 66%. The driving part was designed to rotate the axis of the convex probe by means of a step motor equipped with reduction gears and spur gears attached to the motor so that the probe could enable us to acquire a series of 2-dimensional images to construct a 3-dimensional image. Acoustic cover of the probe was made of polymers to have the same radius of rotation as that of the convex probe. The controllability of the rotation angle and the structural stability of the probe were confirmed through experimental 3-dimensional images obtained using the developed 3-dimensional sector probe.

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

Controller Design for Decoupling of Scanning probe Data Storage System (두 축간 Coupling 을 고려한 Scanning probe Data Storage 시스템 제어기 설계)

  • Moon, Jun;Yun, Jae-Sang;Jeong, Ji-Young;Lee, Choong-Woo;Chung, Chung-Choo;Kim, Young-Sik
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.2
    • /
    • pp.73-80
    • /
    • 2007
  • Atomic Force Microscopy (AFM)방식을 이용한 Scanning probe Data Storage (SDS) 시스템은 array cantilever 를 이용하여 나노 단위로 데이터 읽기, 쓰기를 하는 시스템이다. 따라서 미디어가 있는 stage 의 x 축과 y 축 및 두 축간 coupling 을 고려한 제어기 설계가 요구된다. 본 논문은 SDS 시스템의 축간 coupling 을 고려하지 않은 기존의 제안된 LQG 에 PI 를 추가한 제어기 구조를 사용한다. 두 축간 coupling 공진의 영향을 최소화 하기 위해 convex optimization 으로 설계된 최적의 position profile를 기준 입력신호로 사용한다. 제안된 제어기를 SDS 시스템에 적용하여 모의실험을 하고 그 결과 position profile 로 인해 각 축간 coupling 공진 영향이 감소하여 tracking performance 가 기존의 LQG 제어기 보다 향상된 것을 확인한다.

  • PDF

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province (조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 -)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • In diagnostic ultrasound, the quality of image affect to diagnose. To maintain suboptimal imaging uniformly, Quality Assurance of Ultrasound equipment should take periodically. This is article about examination the quality of image in diagnostic ultrasound to understand conditions of probes in hospitals. There is comparative study of convex and linear probes on ultrasound using tissue-mimicking phantom included simulated cysts, echogenic structures. The ultrasonic attenuation coefficient versus frequency of 0.5 dB is representative of normal liver and 0.7 dB is representative of fatty liver condition in ultrasound phantom. There are results of convex probe, 0.5 dB, vertical group, cystic masses, high contrast masses are mostly shown but 0.7 dB, mid level in vertical group, cystic masses and high contrast masses are nearly visible. In linear probe, 0.5 dB, mid level in vertical group, two or four of them are shown in cystic masses and high contrast masses but there are not visible in 11 of cases. 0.7 dB, there are mostly appear under 6 in vertical group, two or four of them show in cystic masses and high contrast masses and there are not shown in 40 of cases, besides. Linear probes in fatty liver condition of ultrasound instrument are not good in the quality of image practically. So there needs to be replace and fix of probes. Actually management of ultrasound probes is inadequate in hospitals. So if there are program of evaluation to check probes periodically in hospitals from establishment of the ultrasound equipment, there will get better image and have a suitable condition of instruments further more.

  • PDF

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF

Ultrasonographic Assessment of the Tympanic Membrane and Tympanic Bulla in Normal Dogs: A Preliminary Study (개에서 고막과 고실의 초음파학적 평가)

  • 이해운;엄기동;성윤상;이종원;김정은;오태호;정규식;장광호;장동우
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.97-101
    • /
    • 2004
  • This study was aimed for ultrasonographic assessment of the tympanic membrane and the tympanic bulla in five healthy Beagle dogs. To improve an ultrasonographic image, the ear canal was filled with warm saline, and an 11 MHz linear probe and a 6.5 MHz convex probe were used. The structures of ear component such as ear canal, ear cartilage and tympanic membrane were easily identified. Especially, tympanic membrane was presented as a reflaction surface which was resulted from the different acoustic impedence between the fluid-filled anechoic ear canal and the gas-filled hyperechoic tympanic cavity in normal dogs. In five left-side ears, the saline was infused into the external ear canal after the tympanic membrane had been ruptured experimentally. Both anechoic fluid-filled ear canal and tympanic cavity were clearly identified. In five right-side ears, the surgically fluid-filled tympanic cavity was imaged as a hypoechoic oval shaped structure. When tympanic cavity and ear canal have been contained with fluid, it was difficult to identify whether the tympanic membrane was ruptured or not. For assessment of the ear structure with ultrasonography, the 11 MHz linear probe was considered as an optimal equipment for a serial assessment of ear canal, tympanic membrane and tympanic bulla whereas the 6.5 MHz convex probe was suitable to assess the tympanic cavity. The results suggest that ultrasonography with saline infusion into the ear canal can be used to find the intactness of the tympanic membrane and to assess the fluid- filld tympanic bulla.

Effect of Convex Wall Curvature on Three-Dimensional Behavior of Film Cooling Jet

  • Lee, Sang-Woo;Lee, Joon-Sik;Keon Kuk
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1121-1136
    • /
    • 2002
  • The flow characteristics of film coolant issuing into turbulent boundary layer developing on a convex surface have been investigated by means of flow visualization and three-dimensional velocity measurement. The Schlieren optical system with a spark light source was adopted to visualize the jet trajectory injected at 35° and 90° inclination angles. A five-hole directional pressure probe was used to measure three-dimensional mean velocity components at the injection angle of 35°. Flow visualization shows that at the 90° injection, the jet flow is greatly changed near the jet exit due to strong interaction with the crossflow. On the other hand, the balance between radial pressure gradient and centrifugal force plays an important role to govern the jet flow at the 35° injection. The velocity measurement shows that at a velocity ratio of 0.5, the curvature stabilizes downstream flow, which results in weakening of the bound vortex structure. However, the injectant flow is separated from the convex wall gradually, and the bound vortex maintains its structure far downstream at a velocity ratio of 1.98 with two pairs of counter rotating vortices.

Ultrasound Probe Contamination Classification using ATP Meter (ATP meter를 이용한 초음파 탐촉자의 오염도 분류)

  • Ha, Myeong-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the contamination level was measured using an ATP meter using adenosine triphosphate bioluminescent material to find effective infection control to compensate for the disadvantages of the microbial culture method used for hygiene control of ultrasound probe. The convex probes were selected from six ultrasound probe in the hospital, and the samples were taken in real time before and after cleaning to check the contamination of the probe. In order to classify the pollution degree using the APT meter was classified by category. A total of 78 samples were collected from the ultrasound probe. When the pollution levels before and after cleaning were classified by category, 76.6% of the samples were classified into category 3·4 before cleaning, but they decreased to 23.3% after cleaning. 13.3% before cleaning was in category 1, but increased to 43.3% after cleaning. By classifying the pollution level, it was confirmed that the pollution level was significantly reduced by category. Until now, there was no suitable criterion for determining the contamination level by using ATP meter in medical machines where sample area is small and reused. In this study, criteria for each category were set to measure the contamination level of ATP meter suitable for small sample area such as ultrasound probe, so that contamination level could be determined in real time at the site. Therefore, it is considered that hygiene management for ultrasound probe can be more actively performed.

Common-path OCT Image Using Partial Reflecting Probe (부분 반사 프로브를 사용한 공통경로 OCT 이미지 획득)

  • Park, Jae-Seok;Jeong, Myung-Yung;Kim, Chang-Seok;Han, Jae-Ho;Kang, Jin-U.
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.103-107
    • /
    • 2008
  • Unlike conventional optical coherence tomography systems based on Michelson interferometer, we suggest a common-path OCT system, which does not include a separated configuration between reference signal and sample signal. We optimize the refractive index of partial reflecting probe to induce a balanced intensity of the reference signal. At the end of the probe, convex lens was optimally fabricated to get images of biological samples in the position of focus. Using the experimental system, we could get 2-D images of various biological samples.