• Title/Summary/Keyword: Convert transformer

Search Result 23, Processing Time 0.03 seconds

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

New Single-Phase Power Converter Topology for Frequency Changing of AC Voltage

  • Jou, Hurng-Liahng;Wu, Jinn-Chang;Wu, Kuen-Der;Huang, Ting-Feng;Wei, Szu-Hsiang
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.694-701
    • /
    • 2018
  • This paper proposes a new single-phase power converter topology for changing the frequency of AC voltage. The proposed single-phase frequency converter (SFC) includes a T-type multi-level power converter (TMPC), a frequency decoupling transformer (FDT) and a digital signal processor (DSP). The TMPC can convert a 60 Hz AC voltage to a DC voltage and then convert the DC voltage to a 50 Hz AC voltage. Therefore, the output currents of the two T-type power switch arms have 50 Hz and 60 Hz components. The FDT is used to decouple the 50 Hz and 60 Hz components. The salient feature of the proposed SFC is that only one power electronic converter stage is used since the functions of the AC-DC and DC-AC power conversions are integrated into the TMPC. Therefore, the proposed SFC can simplify both the power circuit and the control circuit. In order to verify the functions of the proposed SFC, a hardware prototype is established. Experimental results verify that the performance of the proposed SFC is as expected.

High Efficiency High-Step-up Single-ended DC-DC Converter with Small Output Voltage Ripple

  • Kim, Do-Hyun;Kim, Hyun-Woo;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1468-1479
    • /
    • 2015
  • Renewable energy resources such as wind and photovoltaic power generation systems demand a high step-up DC-DC converters to convert the low voltage to commercial grid voltage. However, the high step-up converter using a transformer has limitations of high voltage stresses of switches and diodes when the transformer winding ratio increases. Accordingly, conventional studies have been applied to series-connect multioutput converters such as forward-flyback and switched-capacitor flyback to reduce the transformer winding ratio. This paper proposes new single-ended converter topologies of an isolation type and a non-isolation type to improve power efficiency, cost-effectiveness, and output ripple. The first proposal is an isolation-type charge-pump switched-capacitor flyback converter that includes an extreme-ratio isolation switched-capacitor cell with a chargepump circuit. It reduces the transformer winding number and the output ripple, and further improves power efficiency without any cost increase. The next proposal is a non-isolation charge-pump switched-capacitor-flyback tapped-inductor boost converter, which adds a charge-pump-connected flyback circuit to the conventional switched-capacitor boost converter to improve the power efficiency and to reduce the efficiency degradation from the input variation. In this paper, the operation principle of the proposed scheme is presented with the experimental results of the 100 W DC-DC converter for verification.

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

The Study on Economic Evaluation for Investment Cost When the Distribution Automation System is Applied (배전자동화 투자비대 경제적 효과분석에 관한 연구)

  • 하복남;한용희;한병성;이흥호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.407-413
    • /
    • 2003
  • Before expanding of distribution automation application to distribution network, we must examine whether there are economical effect. Investment expense for distribution automation can be divided into facility investment expense, maintenance expense, communication expense, investment expense etc. Effect of distribution automation can classify by effect that can convert into money and effect that can not convert into money. Representative effect is outage time decrease effect, distribution line loss decrease effect, main transformer upload effect, distribution line upload effect, work environment improvement effect of lineman and so on. This paper studied economical effect and break-even Point for investment expense by using data that acquire in KEPCO's distribution network.

Basic Modeling and Analysis for AC Railway System based on BTB Voltage Source Converter (BTB 전압형 컨버터 기반의 전기철도 급전변전 시스템의 기본 모델링 및 해석)

  • Yoo, Hyeong-Jun;Kim, Hak-Man;Jung, Ho-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1737-1742
    • /
    • 2012
  • The scott transformer is used to supply single-phase power to the AC railway system. Since the scott transformer is a passive facility, it cannot regulate load-side voltage according to load change. Meanwhile, the Voltage Source Converter (VSC) is able to convert the voltage and control active and reactive power. In this paper, the feasibility of a AC railway system based on Back-to-Back (BTB) VSC which is composed of a rectifier, a DC-DC converter, a inverter, has been proposed. A three-phase to single-phase BTB VSC is modeled. The proposed AC railway system based on BTB VSC is tested on Matlab/Simulink.

Fast offline transformer-based end-to-end automatic speech recognition for real-world applications

  • Oh, Yoo Rhee;Park, Kiyoung;Park, Jeon Gue
    • ETRI Journal
    • /
    • v.44 no.3
    • /
    • pp.476-490
    • /
    • 2022
  • With the recent advances in technology, automatic speech recognition (ASR) has been widely used in real-world applications. The efficiency of converting large amounts of speech into text accurately with limited resources has become more vital than ever. In this study, we propose a method to rapidly recognize a large speech database via a transformer-based end-to-end model. Transformers have improved the state-of-the-art performance in many fields. However, they are not easy to use for long sequences. In this study, various techniques to accelerate the recognition of real-world speeches are proposed and tested, including decoding via multiple-utterance-batched beam search, detecting end of speech based on a connectionist temporal classification (CTC), restricting the CTC-prefix score, and splitting long speeches into short segments. Experiments are conducted with the Librispeech dataset and the real-world Korean ASR tasks to verify the proposed methods. From the experiments, the proposed system can convert 8 h of speeches spoken at real-world meetings into text in less than 3 min with a 10.73% character error rate, which is 27.1% relatively lower than that of conventional systems.

Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter (단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선)

  • 최세완
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.330-334
    • /
    • 2000
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double- connected inverter to convert 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced and the experimental results are provided.

  • PDF

Single Phase to 3 Phase Conversion Using Cyclo-Converter (Cycloconverter를 이용한 단상-3상 변환에 관한 연구)

  • 박민호;전상대
    • 전기의세계
    • /
    • v.28 no.3
    • /
    • pp.51-56
    • /
    • 1979
  • The purpose of this paper is to study the conversion of single phase to three phase. In the proceeding of phase conversion, it is very convinence to convert two-phase from single phase using cycloconverter before and then two to three phase by scott connection transformer. There are also systematized zero-crossing, mono vibrator and ring counter circuit for the gate trigger circuits of cycloconverter. The wave forms of three phase by experimental results are analyzed and discussed the relation of phase difference among them.

  • PDF

Korean Morphological Analysis Method Based on BERT-Fused Transformer Model (BERT-Fused Transformer 모델에 기반한 한국어 형태소 분석 기법)

  • Lee, Changjae;Ra, Dongyul
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.4
    • /
    • pp.169-178
    • /
    • 2022
  • Morphemes are most primitive units in a language that lose their original meaning when segmented into smaller parts. In Korean, a sentence is a sequence of eojeols (words) separated by spaces. Each eojeol comprises one or more morphemes. Korean morphological analysis (KMA) is to divide eojeols in a given Korean sentence into morpheme units. It also includes assigning appropriate part-of-speech(POS) tags to the resulting morphemes. KMA is one of the most important tasks in Korean natural language processing (NLP). Improving the performance of KMA is closely related to increasing performance of Korean NLP tasks. Recent research on KMA has begun to adopt the approach of machine translation (MT) models. MT is to convert a sequence (sentence) of units of one domain into a sequence (sentence) of units of another domain. Neural machine translation (NMT) stands for the approaches of MT that exploit neural network models. From a perspective of MT, KMA is to transform an input sequence of units belonging to the eojeol domain into a sequence of units in the morpheme domain. In this paper, we propose a deep learning model for KMA. The backbone of our model is based on the BERT-fused model which was shown to achieve high performance on NMT. The BERT-fused model utilizes Transformer, a representative model employed by NMT, and BERT which is a language representation model that has enabled a significant advance in NLP. The experimental results show that our model achieves 98.24 F1-Score.