• Title/Summary/Keyword: Conversion Module

Search Result 364, Processing Time 0.022 seconds

A Study on the Implementation of Digital Radio Frequency Memory (디지털 고주파 메모리 구현에 관한 연구)

  • You, Byung-Sek;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2164-2170
    • /
    • 2010
  • Digital Radio Frequency Memory, ( as DRFM ), is a device with the ability to restore output to the input RF signal in the required time after storing the incoming RF signals. Therefore DRFM is widely used in Jammer, EW Simulator, Target Echo Generator, and so on. This paper proposes its hardware implementation composed with the high frequency part and the digital processing part consisting of RF input/output module and local oscillator module. It is also proposed the replicated signal generation method which is consisted of the Analog-Digital conversion in the form of pulsed RF signal quantization, and FPGA to save and produce the playback signal, and RF signals to produce a Digital-Analog Conversion in the digital processing unit. This proposed scheme applied to test board and confirmed the validity of the proposed scheme through the test results obtained by the simulated input signals.

A Programmable Protocol Data Conversion Algorithm for Industrial Machine Monitoring (산업용 장비 모니터링을 위한 프로그램 가능한 프로토콜 데이터 변환 알고리즘)

  • Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2139-2144
    • /
    • 2017
  • In case of communication method and protocol applied to the industrial field, various kinds and methods are applied to the field according to the environment and hardware configuration specifications. In order to develop and construct an industrial monitoring system, the development of the equipment is carried out through hardware system analysis and communication protocol analysis each time, so that a lot of development costs and time are being entered. In this paper, we proposed a programmable protocol conversion algorithm to support the integrated monitoring of industrial equipment using various protocols. This method can extract the necessary data from the data transmitted by serial communication, NMEA, CAN, Modbus communication method and transmit it to Ethernet. We implemented a communication gateway module that supports various communication methods, and experimented with data conversion and transmission.

Design and analysis of RF-DC power conversion circuit (무선 전력변환장치의 전력변환 회로에 대한 설계 및 분석)

  • Kim, Yong-Sang;Im, Sang-Uk;Lee, Yong-Je;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.35-42
    • /
    • 2003
  • We have studied DC energy conversion of RF card by wireless communication. In order to attain an objective, it used the system which is a Rectenna. The main purpose of energy conversion system is the operation of the circuits at RF-ID system. The proposed RF-ID system is a lot classified with the reader and tag. Reader is a kind of the base station role supporting RF energy. And priority tag convert RF energy from the reader it was delivered with a wireless to DC energy. The energy which is converted like Tag. It transmits to the reader characteristic ID of each card. The tag is mainly divided into rectifier, power module, memory and controller. The FRAM maintains the data like a ROM in no-power situation. And the advantage is a low power element compared with other EEPROM. There are two considerations, when RF energy is converted into DC source by wireless. One is energy amount supported from the reader, the other is high power efficiency. This paper presents a study of simulation and experiments on the RF-DC conversion circuit in tag by the power efficiency concentrated.

  • PDF

The Performance and Efficiency Analysis of a PVT System Compared with a PV module and a Solar collector (PVT 시스템의 PV 모듈 및 태양열 집열기 대비 성능 및 효율 비교분석)

  • Euh, Seung-Hee;Lee, Jeong-Bin;Choi, Yun-Sung;Kim, Dae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.1-10
    • /
    • 2012
  • A photovoltaic/thermal (PVT)solar system is the solar technology that allows for simultaneous conversion of solar energy into both electricity and heat. This paper compared the performance of PVT system with a conventional PV module and solar collector and analyzed electrical and thermal efficiency of PVT system in terms of solar irradiance and inlet temperature of the working fluid. Based on the experimental data, thermal and electrical efficiencies of he glazed PVT system were57.9% and14.27% under zero reduced temperature condition which were lower by 13.6% than the solar thermal absorber plate and by 0.08% than the PV module respectively. For the unglazed PVT system it had lower thermal efficiency than the solar thermal absorber plate but higher electrical performance than the PV module due to the cooling effect by the working fluid. However, total efficiency of the glazed PVT system was72.2% which was higher than combined efficiencies of the solar collector and PV module. Besides, total efficiency of the PVT system would be much higher if calculated based on unit area.

A study on the DSP Analysis for the CAT application (CAT 응용을 위한 신호처리 분석에 관한 연구)

  • Jeon, Dong-Keun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.30-39
    • /
    • 1995
  • In this paper, study on implementation of FFT analyzer applied to CAT, A/D conversion module, DSP module and VXIbus interface module are implemented in hardware and calculation program and control software are implemented in DSP module and VXIbus interface module, respectively. The control of the modules using PC is realized in software. The real time bandwidth of the FFT analyzing device is 100KHz. At sampling rate of 200KHz and with 2048 point FFT, the result of applying sine, triangular and rectangular wave of 20KHz to FFT analyzing device is compared with the FFT analyzed results of Hewlett-Packard 3562A dynamic output range of -40dBV- +30dBV, correct results are obtained and results of applying 10KHz, 20KHz and 50KHz input are compared and the correct values are obtained.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

The Performance and Efficiency Analysis of a PVT System Compared with a PV module and a Solar collector (PVT 시스템의 PV 모듈 및 태양열 집열기 대비 성능 및 효율 비교분석)

  • Euh, Seung-Hee;Lee, Jeong-Bin;Choi, Yun-Sung;Kim, Dae-Hyun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.60-67
    • /
    • 2011
  • A photovoltaic/thermal(PVT)solar system is the solar technology that allows for simultaneous conversion of solar energy into both electricity and heat. This paper compared the performance of PVT system with a conventional PV module and solar collector and analyzed electrical and thermal efficiency of PVT system in terms of solar irradiance and inlet temperature of the working fluid. Based on the experimental data, thermal and electrical efficiencies of the glazed PVT system were 57.9% and 14.27% under zero reduced temperature condition which were lower by 13.6% than the solar thermal absorber plate and by 0.08% than the PV module respectively. For the unglazed PVT system, it had lower thermal efficiency than the solar thermal absorber plate but higher electrical performance than the PV module due to the cooling effect by the working fluid. However, total efficiency of the glazed PVT system was 72.2% which was higher than combined efficiencies of the solar collector and PV module. Besides, total efficiency of the PVT system would be much higher if calculated based on unit area.

  • PDF

A study on the power system restoration simulator (전력계통 고장복군 교육 시스템에 관한 연구)

  • Lee, H.J.;Kim, J.M.;Lee, K.S.;Park, S.M.;Song, I.J.;Lee, N.H.;Bae, J.C.;Hwang, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.181-183
    • /
    • 2003
  • This paper presents an operator training simulator for power system restoration against massive black-out. The system is designed especially focused on the generality and convenient setting up for initial condition of simulation. The former is accomplished by using on line calculation methodology, and PSS/E data is used to define the initial situation. The proposed simulator consists of three major components - the Power flow(PF) module, data conversion(CONV) module and CUI subsystem. PF module calculates power flow, and then checks overvoltage of buses and overflow of lines. CONV module composes an Y-Bus array and a data base at each restoration action. The initial Y-Bus array is constructed from PSS/E data. The user friendly GUI module is developed including graphic editor and built-in operation manual. As a result, the maximum processing time for one step operation is 15 seconds, which is adequate for training purpose. Comparison with PSS/E simulation proves the accuracy and reliability of the training system.

  • PDF

A Trust Management Model for PACS-Grid

  • Cho, Hyun-Sook;Lee, Bong-Hwan;Lee, Kyu-Won;Lee, Hyoung
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.144-149
    • /
    • 2007
  • Grid technologies make it possible for IT resources to be shared across organizational and security domains. The traditional identity-based access control mechanisms are unscalable and difficult to manage. Thus, we propose the FAS (Federation Agent Server) model which is composed of three modules: Certificate Conversion Module (CCM), Role Decision Module (RDM), and Authorization Decision Module (ADM). The proposed FAS model is an extended Role-Based Access Control (RBAC) model which provides resource access capabilities based on roles assigned to the users. FAS can solve the problem of assigning multiple identities to a shared local name in grid-map file and mapping the remote entity's identity to a local name manually.

Prototype Development for BIM based Thermal Insulation and Condensation Performance Evaluation of Apartment Housings

  • Oh, Hyangok;Cho, Daegu;Jang, Hyang-In;Hong, Soungwook;Lee, Myung Sik
    • Architectural research
    • /
    • v.17 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • Insulation and condensation performance evaluation (I&CPE) is an important energy analysis. While considerable amount of data are already represented in a Building Information Model (BIM), the lack of interoperability between BIM modeling and I&CPE programs prevents the simulation process from being efficient and accurate. This study proposes a prototype of a BIM-based I&CPE simulation program, in order to enhance the interoperability between BIM modeling and I&CPE programs. This study discusses the information flow process, defines the required information and its level of detail, develops standardized libraries, and finally proposes a prototype that consists of a data extraction module, conversion module, and performance module. The assurance of interoperability between systems might greatly benefit architects and energy professionals.