• Title/Summary/Keyword: Convergent channel

Search Result 33, Processing Time 0.023 seconds

Effect of Rib Angle on Thermal Performance in a Two Wall Convergent/Divergent Channel with Ribs on One Wall (양측면 수축/확대 사각채널에서 한면에 설치된 리브의 각도가 열성능에 미치는 효과)

  • Ahn, Soo Whan;Lee, Myung Sung;Bae, Sung Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.195-200
    • /
    • 2015
  • The thermal performance in the channels with two-wall rectangular convergent/divergent cross-sectional areas along the axial distance was investigated experimentally. The ribbed rectangular convergent/divergent channels were manufactured with a fixed rib height (e) = 10 mm and the ratio of rib spacing (p) to height (e) = 10. Three different parallel angled ribs (a = $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) were each placed on the channel's one sided wall only. The convergent channel of $D_{ho}/D_{hi}=0.67$ and the divergent channel of $D_{ho}/D_{hi}=1.49$ were considered. The ribbed divergent channel produced better thermal performance than the ribbed convergent channel in three different restrictions; identical flow rate, identical pumping power, and identical pressure loss.

Measurement of the Film Cooling Effectiveness using Pressure Sensitive Paint on Convergent/Divergent Channel (압력감응페인트를 이용한 확대/축소 유로에서의 막냉각 효율 측정)

  • Park, Seoung-Duck;Lee, Ki-Seon;Kim, Sung-Ha;Kim, Hark-Bong;Kwak, Jea-Su;Kim, Chun-Teak;Yang, Gyae-Byung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.31-37
    • /
    • 2008
  • Film cooling effectiveness on the convergent or divergent channel was measured by pressure sensitive paint technique. The channel convergent or divergent angle was changed from $-5^{\circ}$ to $10^{\circ}$ and the tested blowing ratios were 0.5, 1 and 2. Results showed that the film cooling effectiveness on the convergent channel was not much affected by the convergent angle. With divergent film cooled surface, the film cooling effectiveness near the injection hole decreased as the divergent angle increases. However, the film cooling effectiveness at far downstream from the hole showed opposite trend. For the non-film cooled surface inclined case, the film cooling effectiveness was not much affected by the divergent angle.

Heat Transfer and Frictions in the Convergent/divergent Channel with Λ/V-shaped Ribs on Two Walls

  • Kim, Beom-soo;Lee, Myung-sung;Ahn, Soo-whan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.395-402
    • /
    • 2017
  • The local heat transfer and total pressure drops of developed turbulent flows in the ribbed rectangular convergent/divergent channels with ${\Lambda}/V-shaped$ ribs have been investigated experimentally. The channels have the exit hydraulic diameter ($D_{ho}$) to inlet hydraulic diameter ($D_{hi}$) ratios of 0.67 for convergence and 1.49 for divergence, respectively. The ${\Lambda}/V-shaped$ ribs with three different flow attack angles of $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ are manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (S) to height (e) of 10 on the walls. Thermal performances of the ribbed rectangular convergent/divergent channels are compared with the smooth straight tube under identical pumping power. The results show that the flow attack angle of $45^{\circ}$ with ${\Lambda}-shaped$ rib has the greatest thermal performance at all the Reynolds numbers studied in the convergent channel; whereas, the flow attack angle of $60^{\circ}$ with V-shaped rib has the greatest thermal performance over Reynolds number of 30,000 in the divergent channel.

Heat Transfer and Friction in Rectangular Convergent Channels with Ribs on One Wall

  • Kim, Won-Cheol;Lee, Myung-Sung;Bae, Sung-Taek;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-18
    • /
    • 2014
  • The local heat transfer of developed turbulent flows in the stationary ribbed rectangular convergent channels has been investigated experimentally. The rectangular convergent channels with one ribbed surface only have the inclination of $0.72^{\circ}$ and $1.43^{\circ}$ at which the ribbed wall is manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (p) to height (e) =10. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000. The local heat transfer characteristics of the rectangular convergent channels are quite different from those of the ribbed square straight channel.

Effect of Inclined Wall Number on Heat Transfer and Friction in the Smooth Channel (매끈한 사각채널에서 경사 벽면 수가 열전달과 마찰에 미치는 효과)

  • Lee, Myung-Sung;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.66-72
    • /
    • 2014
  • The local heat transfer and pressure drop of developed turbulent flows in the smooth convergent/divergent channels with rectangular and square cross-sectional areas along the axial distance have been investigated experimentally. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000. The channel hydraulic diameter ratios of 0.67 and 1.49 in the rectangular channel with 2 inclined walls and the ratios 0.75 and 1.33 in the square channel with 4 inclined walls are considered. The comparison showed that among the four channels the square divergent channel has the highest thermal performance at the identical mass flow rate, at the identical pumping power, and at the static pressure drop.

Analysis on Two Parallel Flows in Convergent Channel (축소 유로내의 두 평행 유동에 대한 해석)

  • Kwon, Jin-Kyung;Kim, Tae-Wook;Kim, Jin-Hyun;Kim, Jae-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.11-18
    • /
    • 2006
  • Compound flow by confluence of two parallel flows through a convergent channel and its choking phenomenon are calculated by one-dimensional isentropic model and completely mixing model. Optical observations and pressure measurements for subsonic/subsonic compound flows are carried out and compared with the results of one-dimensional calculations. As a result, it is found that inlet conditions of one flow influence the behavior of the other flow as well as the choking condition and present experimental data agree well with the results of one-dimensional calculations.

Turbulent Heat Transfer and Friction in Four-Wall Convergent/Divergent Square Channels with One Ribbed Wall (한면에 리브가 설치된 4벽면 수축/확대 채널의 난류 열전달과 유체마찰)

  • Ahn, Soo Whan;Lee, Myung Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.773-778
    • /
    • 2015
  • The local heat transfer and pressure drop of developed turbulent flows in convergent/divergent channels with square axial cross-sectional areas were experimentally investigated to improve the channel design, such as a gas turbine cooling system. Square convergent/divergent channels with one ribbed wall were manufactured with a fixed rib height e of 10 mm and a ratio of rib spacing p to height e of 10. The measurement was conducted for Reynolds numbers from 15,000 to 89,000. Convergent, divergent, and straight channels with ratios $D_{ho}/D_{hi}$ of 0.75, 1.33, and 1.0, respectively, are considered. Of the three channel types, the ribbed divergent channel was found to produce the best thermal performance under identical flow rate, pumping power, and pressure loss conditions.

Adaptive Searching Channel Estimate Algorithm for IMT-Advanced Repeater (차세대 이동통신 중계시스템용 적응형 탐색 채널추정 알고리듬 연구)

  • Lee, Suk-Hui;Lee, Sang-Soo;Lee, Kwang-Ho;Bang, Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.11
    • /
    • pp.32-39
    • /
    • 2009
  • In this thesis, design effective elimination interference algorithm of ICS repeat system for repeater that improve frequency efficiency. Gennerally, LMS Algorithm apply to ICS repeat system. Error convergence speed and accuracy of LMS Algorithm are influenced by reference signal. For improve LMS Algorithm, suggest Adaptive searching channel estimate algorithm. For using channel characteristic, adaptive searching channel estimate algorithm make reference signal similar interference signal by convolution operation and complement LMS algorithm demerit. For make channel similar pratical channel, apply Jake's Rayleigh multi-path model. LMS algorithm and suggested adaptive searching channel estimate algorithm that have 16 taps apply to ICS repeat system under Rayleigh multi-path channel, so simulate with MATLAB. According to simulate, ICS repeat system with LMS algorithm show -40 dB mean square error convergent after 110 datas iteration and ICS repeat system with adaptive searching channel estimate algorithm show -80 dB mean square en-or convergent after 120 datas iteration. Analyze simulation result, suggested adaptive searching channel estimate algorithm show 40 dB accuracy than LMS algorithm.

Effects of Rib Angles on Heat Transfer in a Square Convergent Channel with Ribs on One Wall (한면에 리브가 설치된 4면 수축 사각채널에서 리브의 각도가 열전달에 미치는 영향)

  • Lee, Myung-Sung;Kim, Beom-Soo;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.69-74
    • /
    • 2016
  • The local heat transfer and pressure drops of developed turbulent flows in the convergent channels with square cross-sectional areas along the streamwise distance have been investigated experimentally. Four different parallel angled ribs (a = $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$) are placed to the one sided wall only, respectively. The ribbed walls are manufactured with a fixed rib height (e)=10 mm and the ratio of rib spacing (p) to height (e) = 10. The measurement was run within the range of Reynolds numbers from 22,000 to 79,000. The result shows that the increases in the Nusselt numbers for the flow attack angles can be seen in the order of $30^{\circ}$, $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$.

Heat Transfer and Total Friction Factors in the Convergent Channels with V/⋀-shaped Ribs on Two Opposite Walls (양 벽면에 V/⋀형 리브가 있는 수축 채널의 열전달과 전 마찰계수)

  • Lee, Myung-Sung;Heo, Meo-Seong;Jeong, Ui-Jae;Park, Young-Joon;Yoo, Jung-Hyun;Im, Gun-Woo;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.66-71
    • /
    • 2016
  • The measurements of heat transfer and total friction factors for turbulent flows in the convergent rectangular channels with two opposite in-line ribbed walls are reported. The study has covered three different angled ribs ($30^{\circ}$, $45^{\circ}$ and $60^{\circ}$) and Reynolds number in the range of 22,000 to 75,000. The channel, composing of ten isolated copper sections in the length of test section of 1 m, has the channel convergence ratio of $D_{ho}/D_{hi}=0.67$. The results show that the ribs pointing downstream (${\wedge}-shaped$) is somewhat greater than the ribs pointing upstream (V-shaped) in the dimensionless Nusselt number and total friction factors.