• 제목/요약/키워드: Conventional water treatment process

검색결과 255건 처리시간 0.026초

정수처리공정에서 bisphenol-A의 제거에 관한 연구 (Bisphenol-A Removal in Conventional Water Treatment Systems)

  • 김혜리;이윤진;박선구;남상호
    • 한국환경보건학회지
    • /
    • 제30권1호
    • /
    • pp.59-64
    • /
    • 2004
  • This study was carried out to investigate influencing factors of bisphenol A(BPA) removal characteristic in conventional water treatment systems to be connected with coagulation, sedimentation, filtration and disinfection. The result are summarized as follows; In BPA removal, optimal doses of PAC, alum, ferric chloride were 7.5 mg Al/L, 10.0 mg AI/L, 15.0 mg Fek. PAC was most effective coagulant to remove BPA. In coagulation process, BPA removal efficiency were increased about 2% by adjusting pH of raw water as 6. At temperature rise 1$0^{\circ}C$, BPA removal efficiency were increased 0.94%. but BPA removal efficiency in sand filtration process were under 1 %ie, so that BPA was almost not removed. At free chlorine dose 1, 2 mg/L, the reaction rate constant k in the BPA removal have been calculated to be 0.397, 0.953 min$^{-1}$ . At free chlorine dose 1, 2 mg/1-, degradation reaction of BPA was completed during 10 min and BFA removal efficiencies were 97.66, 99.99% at this time.

표준정수처리 파일럿에서 Cryptosporidium 유사체를 이용한 Cryptosporidium 제거효율 평가 (Evaluation on Removal Efficiency of Cryptosporidium using Surrogate in Pilot Plant of Conventional Water Treatment Process)

  • 박상정;정현미;최희진;전용성;김종민;김태승;정동일
    • 한국물환경학회지
    • /
    • 제26권3호
    • /
    • pp.399-405
    • /
    • 2010
  • In order to quantify removal efficiency of Cryptosporidium in water treatment process and evaluate factors influencing removal efficiency of Cryptosporidium in each step of water treatment process, large pilot plant system ($100m^3/day$) and Cryptracer, surrogate of Cryptosporidium, were used. The removal efficiency of Cryptracer was around 0.8~1 log in coagulation process and 3.3~4.8 log in sand filtration process under ordinary environmental conditions. Factors influenced removal efficiency of Cryptracer were high fluctuate turbidity and water temperature. High fluctuate turbidity made difficult to adjust optimum PAC concentration, caused to drop removal efficiency of coagulation process (0.5 log). Inadequate coagulation process influenced to sand filtration process (2.1 log), caused to decline of removal efficiency in the whole process (2.6 log). Low temperature below $2^{\circ}C$ also influenced coagulation process (0.6 log). Therefore, It is shown that careful attention in the control of Cryptosporidium is needed in flood period, when high fluctuate turbidity would be, and winter period of low temperature.

기존 하수처리장 성능개선을 위한 NPR공정의 적용 (An Application of the NPR Process for the Treatability Improvement of an Existing Sewage Treatment Plant)

  • 문태훈;고광백;송의열
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.756-760
    • /
    • 2007
  • Most of the sewage treatment plants in Korea are being operated by using the conventional activated sludge process. Recently, as the water criteria have been strict with regard to such main culprits of eutrophication, the existing sewage treatment plants are obliged to upgrade their treatment technology to meet the criteria. Under such circumstances, this study was aimed at analyzing the conditions of an existing sewage treatment plants in Korea, and thereupon, test its treatment performance for the actual sewage water by operating a pilot plant. When the pilot plant was operated with the NPR process at the capacity of $30m^3/day$, the average contents of BOD, $COD_{Mn}$, SS, T-N and T-P in the effluents were 7.0 mg/L, 9.7 mg/L, 5.1 mg/L, 8.0 mg/L and 0.23 mg/L, respectively, which were very stable in general. Accordingly, if the NPR process used for this pilot plant to upgrade the treatment technology for the sewage treatment plat could be adopted, the effluent water quality criteria effective beginning from 2008 would be met.

Caffeine과 Carbamazepine: 낙동강 수계에서의 검출 및 정수처리 공정에서의 거동 (Caffeine and Carbamazepine: Detection in Nakdong River Basin and Behavior under Drinking Water Treatment Processes)

  • 손희종;염훈식;정종문;장성호;김한수
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.837-843
    • /
    • 2012
  • The aims of this study were to investigated the occurrence of caffeine and carbamazepine in Nakdong river basin (8 mainstreams and 2 tributaries) and the behavior of caffeine and carbamazepine under drinking water treatment processes (conventional and advanced processes). The examination results showed that caffeine was detected at all sampling sites (5.4~558.5 ng/L), but carbamazepine was detected at five sampling sites (5.1~79.4 ng/L). The highest concentration level of caffeine and carbamazepine in the mainstream and tributaries in Nakdong river were Goryeong and Jinchun-cheon, respectively. These pharmaceutical products were completely removed when they were subject to conventional plus advanced processes of drinking water treatment processes. Conventional processes of coagulation, sedimentation and sand-filtration were not effective for their removal, while advanced processes of ozonation and biological activated carbon (BAC) filtration were effective. Among these pharmaceuticals, carbamazeoine was more subject to ozonation than caffeine.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

이상 혐기성 막공정에 의한 침출수 처리 모니터링 (Monitoring of the Treatment of Leachate by Two Phase Anaerobic Membrane Process (TPAMP))

  • 황문현;현승훈;장남정;조재원;김인수
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.151-157
    • /
    • 2002
  • Landfill leachate is one of highly contaminated and heterogeneous wastewater. The leachate from initial landfill can be treated by anaerobic process because it contains biodegradable matters, particularly, volatile fatty acids (VFAs). However, the anaerobic treatment of leachate is generally required longer hydraulic retention time (HRT) than aerobic process and another treatment process to satisfy effluent concentration. Therefore the modification of conventional anaerobic treatment is needed. Two phase anaerobic membrane process (TPAMP) is an integrated membrane process to be able to separate anaerobic metabolism into two phase which are acidogenesis and methanogenesis for improvement of anaerobic treatment efficiency. In this study, the efficiency of TPAMP and conventional anaerobic treatment were compared in terms of HRT, effluent SCOD, VFAs Membrane used in TPAMP was the UF of capillary type with the surface area of $0.048m^2$. The average effluent SCOD of conventional anaerobic treatment was 1352 mg/L and the removal was 96 % at HRT 60 days, while in TPAMP, 927 mg/L and 98% at HRT 30 days.

기존 하수처리장에서의 처리 효율개선에 관한 연구 (A Study on the improvement of treatment efficiency in a conventional sewage treatment plant)

  • 안철우;박진식;문추연
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.50-56
    • /
    • 2000
  • In this study, sewage were treated with operating Two-step Aeration System and conventional activated sludge process together in a condition. At the same HRT 8hr of Two-step Aeration System and Activated Sludge Process, BOD treatment efficiency of 1st sedimentation basin effluent 36.9% by Two-step Aeration system was 12.3% higher than 24.65 by Activated Sludge Process and the COD treatment efficiency 39.8% by two-step Aeration System was 11.6.3% higher than 28.2% by Activated Sludge Process. BOD and COD treatment efficiencies of 2nd sedimentation basin effluent were 88.1% and 85.6% Two-step Aeration System and were 83.8% and 82.3% Activated Sludge Process. In the first treatment, as BOD was relatively removed a lot, F/M ratio 0.17, $0.21{\cdot}BOD/kg{\cdot}MLSS.d$ was maintained by Activated Sludge Process. Therefore it was proved that organic matter treatment efficiency by Two-step Aeration System os Higher than by Activated Sludge Process in a aeration time 8hr. $NH_4^{+}-N$ treatment efficiencies were 55.5% by Two-step Aeration System and 39.75 by Activated sludge Process. $NO_3^{-}-N$ concentration in 2nd. sedimentation basin effluent were 3.33% by Two-step Aeration System and 2.36% by Activated Sludge Process. From this result, Two-step Aeration System was proved more advantageous treatment process for nitrification than Activated Sludge Process. The fluctuation range of BOD, COD and SS concentration in 2nd sedimentation basin effluent $16~33mg/{\ell}$, $15~23mg/{\ell}$ and $14~22mg/{\ell}$ by Two-step Aeration System was smaller than $16~57mg/{\ell}$, $15~25mg/{\ell}$ by Activated sludge Process. Overall the fluctuation range in 2nd sediment basin effluent by was smaller than by Activated Sludge Process. As a result, it is possible for this Two-step Aeration with no facility investment and a little of operation condition change in a conventional sewage treatment plant to get stability and nitrification of treatment water quality.

  • PDF

Pharmaceutical residues: New emerging contaminants and their mitigation by nano-photocatalysis

  • Shah, Aarif Hussain;Rather, Mushtaq Ahmad
    • Advances in nano research
    • /
    • 제10권4호
    • /
    • pp.397-414
    • /
    • 2021
  • The steady growth in population has led to an enhanced water demand and immense pressure on water resources. Pharmaceutical residues (PRs) are unused or non-assimilated medicines found in water supplies that originate from the human and animal consumption of antibiotics, antipyretics, analgesics etc. These have been detected recently in sewage effluents, surface water, ground water and even in drinking water. Due to their toxicity and potential hazard to the environment, humans and aquatic life, PRs are now categorized as the emerging contaminants (ECs). India figures in the top five manufacturers of medicines in the world and every third pill consumed in the world is produced in India. Present day conventional wastewater treatment methods are ineffective and don't eliminate them completely. The use of nanotechnology via advanced oxidation processes (AOP) is one of the most effective methods for the removal of these PRs. Present study is aimed at reviewing the presence of various PRs in water supplies and also to describe the process of AOP to overcome their threat. This study is also very important in view of World Health Organization report confirming more than 30 million cases of COVID-19 worldwide. This will lead to an alleviated use of antibiotics, antipyretics etc. and their subsequent occurrence in water bodies. Need of the hour is to devise a proper treatment strategy and a decision thereof by the policymakers to overcome the possible threat to the environment and health of humans and aquatic life.

정수처리공정의 침전법을 개선하기 위한 대체공정으로 용존공기부상법(DAF)을 사용할 때 여러조건에 대한 처리효율 비교 (Comparison of Removal Rates of Sedimentation and DAF(Dissolved Air Flotation) for various Different Conditions in Water Treatment)

  • 김미정;이병호
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.118-125
    • /
    • 1997
  • Conventional sedimentation method has some limitations for turbidity removal in water treatment because drinking water sources are getting polluted. Removal rates of turbidity using DAF and sedimentation process were compared for various water conditions to know whether DAF is effective to improve sedimentation process. Water samples were clay(gravity 2.65) water 100mg/l, H raw water, mixed water of H raw water and clay 100mg/l, and mixed water of HA(Humic Acid) 5mg/l and clay 100mg/l. Other parameters were temperature, coagulants(Alum, $FeCl_3$), and treatment time. Water temperature greatly affected in removal rates of turbidity for sedimentation and DAF. Generally DAF was more effective in removal rates of turbidity than sedimentation at the same experimental condition. Removal rates of $UV_{254}$ were high to over 90%, and independent of temperature and coagulant.

  • PDF

재래식 정수처리공정에서 조류입자 제거를 위한 DAF Hybrid 공정의 실험적 적용과 입자특성 변화 (Experimental Application of DAF Hybrid Process to Remove Algae Particles for Conventional Water Treatment Processes and Change of Particle Characteristics)

  • 곽동희;유승준
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.516-520
    • /
    • 2008
  • 우리나라는 상수도시설의 노후화와 그 동안의 상수원 수질변화에 대응한 정수처리공정의 개량과 개선이 요구되어지고 있는 상황에 있어서, 기존의 정수처리공정에 어떠한 시설개량이나 설비의 보완 없이 DAF 공정을 추가하여 점토와 조류입자를 효과적으로 제거할 수 있는 DAF hybrid 공정의 적용성을 살펴보고자 일련의 실험을 실시하였다. DAF 공정의 설치위치는 조류입자의 제거에는 응집지나 침전지 전단을 이용하는 DAF-CGS 공정조합보다는 침전지 후단 또는 여과지 전단을 이용하는 DAF-CSF 방식이 더 효과적인 것으로 나타났다. 또한, DAF-CSF hybrid 공정을 도입함으로써 기존의 상수처리조건과 동일한 처리속도(수리학적 부하량)에서 처리효율이 향상될 것이며, 높은 수리학적 부하에서도 재래식 상수도시설에 적용하여 안정된 처리효율을 얻을 수 있을 것으로 판단되었다.