• Title/Summary/Keyword: Conventional system

Search Result 14,428, Processing Time 0.043 seconds

Experimental Study on the MR-Toggle Brace System for Vibration Control (지진응답 제어를 위한 MR-토글 가새 시스템의 실험적 연구)

  • Min Kyung-Won;Lee Myoung-Kyu;Kang Sang-Hoon;Lee Sang-Hyun;Hwang Jae-Seung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.644-651
    • /
    • 2005
  • The purpose of this paper is to compare the control effect of toggle brace system having amplifying displacement mechanism with that of conventional brace system when the identical MR damper is applied to each system. The force-displacement and lone-velocity relationships of MR damper are obtained using harmonic load test and the analytical model for MR damper is presented. White noise excitation tests of a single degree of freedom system with MR-toggle brace system and MR-chevron system are conducted and the transfer functions of the systems are compared. Test results show that the control effect of the toggle system is superior to that of the conventional brace system.

  • PDF

Stability Analysis of Nonlinear Pulse-Modulated System Subject to Gaussian Noise (가우스 잡음을 고려한 비선형 펄스 변조 시스템의 안정도 분석)

  • 강영채
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.67-79
    • /
    • 1982
  • The stability of general pulse-width modulation system with Gaussian random disturbance was discussed . General system is divided into nonlinear and linear elements using the conventional describing function method. The concept of the equivalent admittance was used to find the transfer characteristic of the nonlinear element of the system. In this paper the self-sustained oscillation condition in the autonomous system was derived and the results was analyzed with computer simulation.

  • PDF

An Expert System for NC Part Programming (ESPP-1) (NC파트 프로그래밍을 위한 전문가시스템)

  • 정선환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3091-3097
    • /
    • 1994
  • An expert system for NC part programming of NC lathe (ESPP-1) is developed as a part of Computer-Adied Manufacturing system. Conventional computer-assisted part programming system essentially requires an NC part programmer who is an expert in NC part programming. But the developed ESSP-1 can allow an inexperienced person to make an excellent NC data for the NC Lathe without any problem, since the system has a knowledge base composed of EIA and ISO NC code, feed rate, spindle speed, machining coordinates selection, and tool selection etc., which were directly evoked from some skilled NC part programmers, and referenced some machining handbooks. This paper discusses the algorithm of the expert system for NC part programming of the NC lathe (ESPP-1) and the performance comparisons between the developed expert system and the conventional system.

The Characteristics of a Bypass Air Conditioning System for Load Variation (부하변동에 대한 바이패스 공조시스템의 특성)

  • 김보철;신현준;김정엽
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

Study on the Performance of an ATES Geothermal Heat Pump System and Economic Analysis (ATES 열펌프 시스템 성능 및 경제성 분석에 관한 연구)

  • Oh, Myung-Suk;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • The aim of this study is to investigate the performance of a heating and cooling system with aquifer thermal energy storage(ATES heat pump system) known as one of the underground thermal energy storage application systems. The ATES system was composed of heat pump unit and ATES, which was installed in a factory building located in Anseoung. The system represented very high heating and cooling performance, and showed nearly constant COP at each heating and cooling season due to the stability of EWT. The economic analysis about an ATES system and a conventional system was also executed. The conventional system adopted an air-conditioner in the summer season and a LNG boiler in the winter season. The payback period of the ATES system was estimated by 6.62 years.

Effect of Herd-mix Feeding System formulated by Energy Requirement Levels on the Performance of Lactating Cows (에너지 요구수준에 의하여 조제한 자가배합사료 사양체계가 젖소의 산유능력에 미치는 영향)

  • Sung, H.G.;Kim, D.K.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.773-782
    • /
    • 2004
  • The objective of this work was to establish an approaching method for TMR feeding system in the farm situation by testing the effects of herd-mix feeding system on the performance of lactating cows. Fifty six Holstein cows were fed for the experimental period of 16 months. Prior to test the herd-mix feeding system, animals were kept on conventional feeding system for 4 months, separate feeding of forage with concentrate, then provided 3 types of herd-mix rations formulated by mean level of energy concentration requirement of higher 1/2 ranker in each herd for remaining 12 months to compare the effect on milk yield performance of animals with conventional feeding system by using a switch-over method. The herd-mix feeding system influenced substantially upon the improvements of milk yield(P<0.01) and milk fat percentage(P<0.05). In all of lactational ages, milk yield and milk fat were enhanced by the herd-mix feeding system. Especially, actual milk yield(AMY) and milk fat in the 1st lactating cows, and AMY and 4.0% fat corrected milk yield(FCM) in the 2nd lactating cows were increased signiticantly by the herd-mix feeding system(P<0.05). In the early and mid-stage of lactation, the herd-mix feeding system showed higher AMY and FCM compared with the conventional feeding system although the milk fat was not different. AMY, milk fat and FCM in the late-stage of lactation were increased generally by the herd-mix feeding system. Especially, milk fat and FCM obtained by the herd-mix feeding system were significantly higher than those by the conventional feeding system(P<0.01). The herd-mix feeding system showed a good type of milking curve with a higher persistency of FCM(93.24%) than in conventional one(92.69%). The income over feed cost with the herd-mix feeding system was lA-fold higher than that with the conventional feeding method. In conclusion, the results of this work suggest that the herd-mix feeding system based on a correct level of energy concentration of TMR and well-determined feed ingredients increases not only milk yield of dairy herd by enhancing the performance of cows in early to mid stage of lactation with improved milk persistency but also gross income of dairy farm.

The performance analysis of a novel enhanced turbo coded system with increased time diversity effect (시간 다이버시티 효과를 증대시키는 새로운 ETD-터보 코드 적용시스템의 성능분석)

  • 고연화;하덕호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.73-80
    • /
    • 2003
  • In this paper, we propose a ETD-turbo code(Enhanced Time Diversity turbo code) which is a novel turbo code configuration to increase the time diversity effect and analyze the performance of ETD-turbo coded MC-CDMA system. The ETD-turbo code, which is added another interleaver to the conventional turbo code structure, is consisted. Time diversity effect of the ETD-turbo code is improved by every parity bits converted into interleaver pattern. In order to the performance of the ETD-turbo code, we conduct a computer simulation about interleaver type. And we make comparison between the performance of ETD-turbo coded MC-CDMA system and the conventional turbo coded MC-CDMA system. By the simulation results, ETD-turbo code has less BER than the conventional turbo code and time delay is decreased by reducing iteration numbers. Therefore, it is defined that the performance of ETD-turbo coded MC-CDMA system is improved than the conventional turbo coded MC-CDMA system.

  • PDF

Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior (액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법)

  • Lee, Ji-Young;Kim, Gyung-Chul;Kim, Chul-Hwan;Sheikh, M.I.;Park, Hyun-Jin;Kim, Sung-Ho;Sim, Sung-Woong;Cho, Hu-Seung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.2
    • /
    • pp.18-28
    • /
    • 2012
  • This study was to develop a novel automatic system for measuring St$\ddot{o}$ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St$\ddot{o}$ckigt sizing degree and contact angle. For the St$\ddot{o}$ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Vertebral compression fractures after spine irradiation using conventional fractionation in patients with metastatic colorectal cancer

  • Rhee, Woo Joong;Kim, Kyung Hwan;Chang, Jee Suk;Kim, Hyun Ju;Choi, Seohee;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • v.32 no.4
    • /
    • pp.221-230
    • /
    • 2014
  • Purpose: To evaluate the risk of vertebral compression fracture (VCF) after conventional radiotherapy (RT) for colorectal cancer (CRC) with spine metastasis and to identify risk factors for VCF in metastatic and non-metastatic irradiated spines. Materials and Methods: We retrospectively reviewed 68 spinal segments in 16 patients who received conventional RT between 2009 and 2012. Fracture was defined as a newly developed VCF or progression of an existing fracture. The target volume included all metastatic spinal segments and one additional non-metastatic vertebra adjacent to the tumor-involved spines. Results: The median follow-up was 7.8 months. Among all 68 spinal segments, there were six fracture events (8.8%) including three new VCFs and three fracture progressions. Observed VCF rates in vertebral segments with prior irradiation or pre-existing compression fracture were 30.0% and 75.0% respectively, compared with 5.2% and 4.7% for segments without prior irradiation or pre-existing compression fracture, respectively (both p < 0.05). The 1-year fracture-free probability was 87.8% (95% CI, 78.2-97.4). On multivariate analysis, prior irradiation (HR, 7.30; 95% CI, 1.31-40.86) and pre-existing compression fracture (HR, 18.45; 95% CI, 3.42-99.52) were independent risk factors for VCF. Conclusion: The incidence of VCF following conventional RT to the spine is not particularly high, regardless of metastatic tumor involvement. Spines that received irradiation and/or have pre-existing compression fracture before RT have an increased risk of VCF and require close observation.