• Title/Summary/Keyword: Conventional impression

Search Result 107, Processing Time 0.027 seconds

Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction

  • Pereira, Ana Larisse Carneiro;Medeiros, Vitoria Ramos;Campos, Maria de Fatima Trindade Pinto;Medeiros, Annie Karoline Bezerra de;Yilmaz, Burak;Carreiro, Adriana da Fonte Porto
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.212-222
    • /
    • 2022
  • PURPOSE. To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed completearch frameworks, as well as on patient satisfaction. MATERIALS AND METHODS. 17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (P<.05). RESULTS. The time with DI was shorter than with CI (DI, $\tilde{x}=02:58$; CI, $\tilde{x}=31:48$) (P<.0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: $\tilde{x}=05:36$; 4: $\tilde{x}=09:16$) (P<.0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (P<.005). CONCLUSION. Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

Use of Intraoral Scanners for Fabricating Fixed Restoration: Clinical Tips (구강 스캐너를 사용한 고정성 보철 수복 시 고려사항)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.524-528
    • /
    • 2019
  • With the advances of CAD-CAM (computer-aided design and computer-aided manufacturing) technology, the field of modern clinical dentistry has been dramatically changed. The first step in the digital workflow for tooth-supported dental prosthesis is a data acquisition with intraoral digital or conventional impression techniques. For the accuracy of intraoral digital impression data, the basic principles of conventional impression should be applied. It is necessary to obtain a good visibility with properly-dried field and well-exposed margin of the prepared abutment. Currently, the equi- or supra-gingival finish line can be recommended as an indication for intraoral digital impression. The scan data are generally exported to '.stl' file format, which has only morphological information of black and whitem while '.obj' file format can store data on color and texture.

  • PDF

Comparison of different impression techniques for edentulous jaws using three-dimensional analysis

  • Jung, Sua;Park, Chan;Yang, Hong-So;Lim, Hyun-Pil;Yun, Kwi-Dug;Ying, Zhai;Park, Sang-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.179-186
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare two novel impression methods and a conventional impression method for edentulous jaws using 3-dimensional (3D) analysis software. MATERIALS AND METHODS. Five edentulous patients (four men and one woman; mean age: 62.7 years) were included. Three impression techniques were used: conventional impression method (CI; control), simple modified closed-mouth impression method with a novel tray (SI), and digital impression method using an intraoral scanner (DI). Subsequently, a gypsum model was made, scanned, and superimposed using 3D analysis software. Mean area displacement was measured using CI method to evaluate differences in the impression surfaces as compared to those values obtained using SI and DI methods. The values were confirmed at two to five areas to determine the differences. CI and SI were compared at all areas, while CI and DI were compared at the supporting areas. Kruskal-Wallis test was performed for all data. Statistical significance was considered at P value <.05. RESULTS. In the comparison of the CI and SI methods, the greatest difference was observed in the mandibular vestibule without statistical significance (P>.05); the difference was < 0.14 mm in the maxilla. The difference in the edentulous supporting areas between the CI and DI methods was not significant (P>.05). CONCLUSION. The CI, SI, and DI methods were effective in making impressions of the supporting areas in edentulous patients. The SI method showed clinically applicability.

A study on the perception of dental hygienists according to the clinical application experience of digital intraoral scanners: focusing on the comparison with conventional impression (구강 스캐너 임상적용 경험에 따른 치과위생사의 인식 연구: 전통적 인상채득과의 비교를 중심으로)

  • Myoung-Hee, Kim;Young Sun, Hwang;Hang-Sik, Park
    • Journal of Korean Academy of Dental Administration
    • /
    • v.10 no.1
    • /
    • pp.84-92
    • /
    • 2022
  • Impression taking is one of the most frequently performed tasks within the legal scope of dental hygienists. This study aims to compare traditional impression and digital impression taking in various aspects with dental hygienists who have experience using digital intraoral scanners. A total of 61 subjects were included in this analysis. Traditional and digital impression taking were compared, and the perception of intraoral scanners was classified into four factors through exploratory factor analysis. After a normality test of the main variables was performed, a non-parametric test was performed. In terms of the adequacy of the size of the tool inserted into the oral cavity, traditional impression taking was more positive, and there was no significant difference in the precision of impression taking, fit of the prosthesis, and time efficiency. In contrast, the digital intraoral scanner was positive in terms of reducing nausea. In the comparison between the items of the digital intraoral scanner, relatively low satisfaction was shown in terms of convenience of use. This study compared traditional impression taking based on the experience of dental hygienists using oral scanners. It is hoped that this will be one step closer to universalization. In addition, appropriate training on how to use them should be provided.

INFLUENCE OF INDIVIDUAL TOOTH TRAY ON THE TEETH WITH UNDERCUT IN IMPRESSION TAKING (언더컷이 있는 치아에서 개별 치아 트레이가 인상채득에 미치는 영향)

  • Seo Kowang-Won;Shin Sang-Wan;Lee Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Problem : The several studies were reported to the effects of individual tooth tray with the parallel tooth, but not reported to the effect of individual tooth tray with severe undercut in impression making. Purpose : The purpose of this study is to examine the effect of individual tooth tray; 1) the accuracy of impression in terms of distance. 2) reproducibility of pocket. Material and methods : In this study, a metal model with 3 teeth including tooth prepared 30-degree undercut and gingival crevice of the depth 5mm, width 0.4mm was cast. Impressions of the metal model were taken in 5 times used 4 kinds of impression materials with individual tooth tray and another impression taking were made with conventional method without individual tooth, used same materials, procedure. The stone models were made. Distances between abutments were measured with a Micromeasurescoup-mm. Result : The following results were obtained ; 1. In the comparisonof inter-abutment distance between parallel tooth without individual tooth tray, 4elastomeric materials have not significant difference to the metal model(p>0.05). 2. In the comparisonof inter-abutment distance with undercut tooth without individual tooth tray, 4elastomeric materials have a significant difference to the metal model(p<0.05), especially polyether's dimensional change is large. 3. If individual tooth tray was used to take impression in abutment teeth with severe undercut, more stable results was achieved easily than conventional method. (p>0.05). 4. It is not true that the pressure of impression material with individual tooth tray increased to gingival sulcus. Conclusion : By the results, I knew the fact that individual tooth tray was useful impression method on the teeth with severe undercut for the dimensional stability. Also, I could not confirm the fact that individual tooth tray would increase the penetrating pressure into cervice.

Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions

  • Franklin Guillermo Vargas-Corral;Americo Ernesto Vargas-Corral;Miguel Angel Rodríguez Valverde;Manuel Bravo;Juan Ignacio Rosales Leal
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2024
  • PURPOSE. The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques. MATERIALS AND METHODS. The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 ㎛2) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and P-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions. RESULTS. Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 ㎛ and that for CI group was 209 ± 104 ㎛, and there were statistical differences between them (p = .041). Mean overextension values were 60 ± 59 ㎛ for DI group and 67 ± 73 ㎛ for CI group, and there were no differences between then (p = .553). CONCLUSION. Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner (임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용)

  • Park, Ji-Manm;Park, Eun-Jin;Heo, Seong-Joo
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

Modified soft tissue cast for fixed partial denture: a technique

  • Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.33-36
    • /
    • 2011
  • In process of fabrication of a fixed partial denture, dies are trimmed to expose margins of the preparations. The need for the soft tissue cast is quite evident as the soft tissue emergence profile that surrounds the prepared tooth is destroyed in the process of fabrication. This article describes a modified technique to fabricate the soft tissue cast for the conventional fixed partial denture. The impression made with the polyvinylsiloxane was first poured to prepare the die cast. After retrieval of the cast, the same impression was poured second time with the resin based resilient material to cover the facial and proximal gingival areas. The remaining portion of the impression was poured with the gypsum material. This technique does not require additional clinical appointment, second impression procedure, technique sensitive manipulations with impression, or cumbersome laboratory procedures. The simplicity of this technique facilitates and justifies its routine use in fabrication of the fixed partial denture.