• 제목/요약/키워드: Conventional coil

검색결과 290건 처리시간 0.027초

A Novel Impedance Matching Topology for Magnetically Coupled Wireless Power Transfer

  • Lee, Gunbok;Park, Wee Sang
    • International journal of advanced smart convergence
    • /
    • 제1권2호
    • /
    • pp.16-19
    • /
    • 2012
  • A modified 4-coil magnetic resonance wireless power transfer (MRWPT) system is proposed. Four coils based on 2-coil system with additional two matching coils were used in this topology. When Tx-Rx distance is changed, the input impedance is changed. However, it can be adjusted by coil parameters of matching coils to maintain impedance matching for maximum efficiency. The equivalent circuit of MRWPT system was analyzed for both transmission function and optimum coupling coefficient of the matching coils. By using four spiral resonant coils, these design considerations was experimentally verified. The measured data agreed well with the calculated data and the transmission function of the proposed system was more efficient than that of conventional 2-coil system.

Shorted Turn in the Hybrid Magnet Engine Valve Actuator for Enhanced Dynamic Performance

  • Yi, Hwa Cho;Hwang, Ki Il;Kim, Jihun;Kim, Jin Ho
    • Journal of Magnetics
    • /
    • 제18권4호
    • /
    • pp.466-472
    • /
    • 2013
  • This paper presents a new design of the hybrid magnet engine valve actuator using the shorted turn for enhanced dynamic performance. The quick response of coil electric current is the most important factor that determines the opening and closing performance of the hybrid magnet engine valve. The conventional hybrid magnet engine valve actuator, however, has a delayed initial electric current rising when it is driven by voltage control because of the coil inductance which is a typical characteristic of an electromagnetic coil. A shorted turn is newly placed into the upper yoke of the hybrid magnet engine valve actuator to reduce coil inductance and thus, to hasten the initial electric current rising. We performed a dynamic finite element analysis to demonstrate the improvement of the dynamic characteristics of the hybrid magnet engine valve actuator due to the shorted turn.

수냉식 1MW 고온초전도 동기모터의 설계 (Design of Water-cooled 1MW HTS Synchronous Motor)

  • 백승규;손명환;이언용;권영길;문태선;박희주;김영춘
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.21-28
    • /
    • 2005
  • Superconducting synchronous motors and generators have the field coil composed of superconductor with almost zero resistance at superconducting state. Therefore, copper loss at the conventional field coil is eliminated and the superconducting machine gets higher efficiency. The armature coil of the superconducting machine is composed of copper wire and supported by non-magnetic material such as FRP (Fiber Reinforced Plastic) This paper contains the design Procedure of a 1MW superconducting synchronous motor using high-temperature superconductor only for the field coil. Especially, the armature coil is designed by water-cooling in order to dissipate Joule heat easily. Moreover, 3-dimensional electromagnetic design is conducted to get a proper design result and reduce design errors from 2-dimensional approach.

Analysis of a Linkage Coil for Wireless Power Transmission by Inductive Coupling

  • Gimm, Youn-Myoung;Yoo, Ho-Sang;Kim, Myoung-Wha;Yoo, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • 제8권1호
    • /
    • pp.23-27
    • /
    • 2008
  • Magnetic coupling delivering wireless power in capsular endoscope(CE) is described in this paper. The characteristic of the magnetic flux linkage coil which generates the induced electromotive force(emf) under the magnetic field was analyzed. With the analyzed results, a magnetic flux linkage coil system was developed and tested. It was confirmed that the magnetic flux linkage coil system could supply more than 50 mW power at 125 kHz without changing the structure of conventional CE.

One Coil을 이용한 VCB의 PMA 설계 (Design of Permanent Magnetic Actuator for VCB with One Coil)

  • 김진철;김지호;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.878-880
    • /
    • 2004
  • In this paper, a new design of permanent magnetic actuator (PMA) for vacuum circuit breaker (VCB) with one coil is proposed. Electromagnetic characteristic analysis is performed numerically using finite element method (FEM) considering the nonlinearity of magnetic core and permanent magnet. The characteristics of proposed PMA with one coil is similar with that of the conventional PMA with two coils. The proposed PMA can simplify the control circuit because of the usage of one coil. Therefore, the reliability of VCB can be improved with the proposed model.

  • PDF

Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs

  • Park, Hwan-Hyung;Jung, Suk-Hwan;Yoon, Juil;Jee, Kwang Koo;Han, Jun Hyun;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.214-221
    • /
    • 2019
  • Objective: To investigate the effects of reversing the coiling direction of nickel-titanium closed-coil springs (NiTi-CCSs) on the force-deflection characteristics. Methods: The samples consisted of two commercially available conventional NiTi-CCS groups and two reverse-wound NiTi-CCS groups (Ormco-Conventional vs. Ormco-Reverse; GAC-Conventional vs. GAC-Reverse; n = 20 per group). The reverse-wound NiTi-CCSs were directly made from the corresponding conventional NiTi-CCSs by reversing the coiling direction. Tensile tests were performed for each group in a temperature-controlled acrylic chamber ($37{\pm}1^{\circ}C$). After measuring the force level, the range of the deactivation force plateau (DFP) and the amount of mechanical hysteresis (MH), statistical analyses were performed. Results: The Ormco-Reverse group exhibited a significant shift of the DFP end point toward the origin point (2.3 to 0.6 mm), an increase in the force level (1.2 to 1.3 N) and amount of MH (1.0 to 1.5 N) compared to the Ormco-Conventional group (all p < 0.001), which indicated that force could be constantly maintained until the end of the deactivation curve. In contrast, the GAC-Reverse group exhibited a significant shift of the DFP-end point away from the origin point (0.2 to 3.3 mm), a decrease in the force level (1.1 to 0.9 N) and amount of MH (0.6 to 0.4 N) compared to the GAC-Conventional group (all p < 0.001), which may hinder the maintenance of force until the end of the deactivation curve. Conclusions: The two commercially available NiTi-CCS groups exhibited different patterns of change in the force-deflection characteristics when the coiling direction was reversed.

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.85-89
    • /
    • 2002
  • 목적 : 사람에 비하여 크기가 현저히 작은 동물의 자기공명영상 촬영을 위하여 상용으로 인체에 적용하는 Head 코일보다 원통 반지름이 작은 Low-Pass Type Birdcage 코일을 제작함으로써 보다 큰 신호대잡음비 (Signal-to-Noise Ratio. SNR)를 얻고자 하였다. 방법 : 자기공명영상을 얻기 위해 Spin Echo 펄스시퀀스와 Fast Spin Echo 펄스시퀀스를 사용하였다. T1 강조영상을 얻기 위한 Spin Echo 펄스시퀀스의 매개변수는 TR/TE=300/17 ㎳, Matrix=256$\times$256, Field Of View (FOV)=150 mm, Slice Thickness=2 mm 이었다. T2 강조영상을 얻기 위한 Fast Spin Echo 펄스시퀀스의 매개변수는 TR/TE=3000/96 ㎳, Matrix=256$\times$256, Field Of View (FOV)=150 mm, Slice Thickness=2 mm 이었다. 원통의 지름이 13 cm인 Birdcage 코일은 12개의 elements로 구성되어 있으며 길이는 22 cm로 제작되었다. 결과 : 코일 원통의 반지름의 크기에 따른 SNR을 비교하기 위하여 인체용 Knee 코일과 동물용으로 제작된 코일을 이용하여 각각의 팬톰 영상을 획득하였다. 팬톰 영상으로부터 측정된 SNR의 값을 통해 반지름이 작은 동물용 코일의 SNR이 더 크다는 걸 확인할 수 있었다. 토의 및 결론 : 본 연구를 통하여 같은 형태의 Birdcage 코일일 경우 원통의 반지름에 따라 SNR이 다르며, 특히 반지름이 작을 때 SNR이 더 크다는 것을 알 수 있었다. 따라서 코일의 크기에 비해 촬영하고자 하는 대상물의 부피가 작은 경우 대상물의 부피에 맞추어 코일을 제작하면 SNR이 보다 뛰어난 영상을 얻을 수 있을 것으로 사료된다.

  • PDF

인덕션 쿡탑 기구물 형상변경이 Heatsink 및 Coil 냉각성능에 미치는 영향에 대한 연구 (Study on the Cooling Performance of Heatsink for Induction Cooktop using Computational Fluid Dynamics)

  • 박동호;권명근;이동범;서응렬;박용종
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.33-37
    • /
    • 2015
  • A numerical study on the IPM/Bridge Diode cooling and coil cooling has been performed. Results are presented as plots of thermal resistance, temperature drop and RPM-ratio. CFD analysis for conventional cooling system has been performed as a reference case. As the RPM-Ratio was increased, heatsink thermal resistance and coil temperature were decreased. IPM/Bridge Diode thermal resistance and temperature of the coil is tended to be trade-off. The temperature of coil closest to the AC-motor fan showed the most significant change in accordance with duct design. The temperature of coil located at the top of DC-motor fan showed the most significant variation as the cooling air passes the heatsink fin area.

Magnetic Particle Separation by an Optimized Coil: A Graphical User Interface

  • Rouhi, Kasra;Hajiaghajani, Amirhossein;Abdolali, Ali
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.214-219
    • /
    • 2017
  • Magnetic separators that clean the fluid stream from impurities, protect the installations in numerous industries. This paper introduces a graphical user interface (GUI) which proposes an optimized coil separating magnetic particles with a radius from 1 up to 500 µm. High gradient magnetic fields are employed in an arbitrary user defined fluidic channel which is made of a nonmetallic material. The effects of coil parameters are studied and adjusted to design an optimum coil with a minimum Ohmic loss. In addition, to design the coil scheme based on the particle movements, a mathematical particle-tracing model within the fluid channels has been utilized. In comparison to conventional magnetic separators, this model is reconfigurable by the user, produces a weaker magnetic field, allows for continuous purifying and is easy to install, with high separation efficiency. The presented GUI is simple to use, where the coil's manufacturing limitations can be specified.

원격 생체 측정 장치를 위한 다중 발신 코일 구동 드라이버 설계 (Design of a Multiple Transmit Coil Driver for Implantable Telemetry Devices)

  • 유영기
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.609-614
    • /
    • 2015
  • Implanted telemetry systems provide the ability to monitor different species of animals while they move within their cages. Species monitored include mice, rats, rabbits, dogs, pigs, primates, sheep, horses, cattle, and others. A miniature transmitter implanted in each animal measures one or more parameters. Parameters measured include arterial pressure, intra-pleural pressure, left ventricular pressure, intra-ocular pressure, bladder pressure, ECG, EMG, EEG, EOG, temperature, activity, and other parameters and transmits the data via radio frequency signals to a nearby receiver. Every conventional dedicated transmitter contains one or more sensors, cpu and battery. Due to the expected life of the battery, the measuring time is limited. To overcome these problems, electromagnetic inductive coupling based wireless power transmission technology using multiple transmit coils were proposed, with each coil having a different active area driven by the coil driver. In this research, a parallel resonance based coil driver and serial resonance based coil driver are proposed. From the experiments we see that the parallel coil driver shows better performance under a low impedance and multiple coils configuration. However, the serial coil driver is more efficient for high impedance transmit coils.