• Title/Summary/Keyword: Conventional Polymerase Chain Reaction

Search Result 123, Processing Time 0.029 seconds

Discrimination and Detection of Erwinia amylovora and Erwinia pyrifoliae with a Single Primer Set

  • Ham, Hyeonheui;Kim, Kyongnim;Yang, Suin;Kong, Hyun Gi;Lee, Mi-Hyun;Jin, Yong Ju;Park, Dong Suk
    • The Plant Pathology Journal
    • /
    • v.38 no.3
    • /
    • pp.194-202
    • /
    • 2022
  • Erwinia amylovora and Erwinia pyrifoliae cause fire blight and black-shoot blight, respectively, in apples and pears. E. pyrifoliae is less pathogenic and has a narrower host range than that of E. amylovora. Fire blight and black-shoot blight exhibit similar symptoms, making it difficult to distinguish one bacterial disease from the other. Molecular tools that differentiate fire blight from black-shoot blight could guide in the implementation of appropriate management strategies to control both diseases. In this study, a primer set was developed to detect and distinguish E. amylovora from E. pyrifoliae by conventional polymerase chain reaction (PCR). The primers produced amplicons of different sizes that were specific to each bacterial species. PCR products from E. amylovora and E. pyrifoliae cells at concentrations of 104 cfu/ml and 107 cfu/ml, respectively, were amplified, which demonstrated sufficient primer detection sensitivity. This primer set provides a simple molecular tool to distinguish between two types of bacterial diseases with similar symptoms.

Comparative Evaluation of Loop-Mediated Isothermal Amplification (LAMP) and Conventional PCR for Detection of Shiga-Toxin-Producing Escherichia coli (STEC) in Various Food Products

  • Hyejin Jang;Yong Sun Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.347-355
    • /
    • 2023
  • In this study, polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) were compared in terms of their ability to detect shiga-toxin-producing Escherichia coli (STEC). Various foods were artificially inoculated with STEC to evaluate the limit of detection (LOD), limit of quantification (LOQ), sensitivity, specificity, and efficiency of PCR and LAMP. The LODs were ≤104 and ≤103 CFU/mL for PCR and LAMP, respectively. The LOQs did not differ between PCR and LAMP. However, of the four considered food types, the sensitivities differed by a maximum of 11.1% for seasoned meat and by a minimum of 8.1% for ground beef. LAMP had higher sensitivity than that of PCR and 100% specificity for all four food types. Therefore, LAMP is a reliable molecular method for detecting STEC as comparable to PCR assay, and its specificity and sensitivity are superior to those of PCR, depending on the food type.

A Rapid and Sensitive Detection of Aflatoxin-producing Fungus Using an Optimized Polymerase Chain Reaction (PCR)

  • Bintvihok, Anong;Treebonmuang, Supitchaya;Srisakwattana, Kitiya;Nuanchun, Wisut;Patthanachai, Koranis;Usawang, Sungworn
    • Toxicological Research
    • /
    • v.32 no.1
    • /
    • pp.81-87
    • /
    • 2016
  • Aflatoxin B1 (AFB1) is produced by Aspergillus flavus growing in feedstuffs. Early detection of maize contamination by aflatoxigenic fungi is advantageous since aflatoxins exert adverse health effects. In this study, we report the development of an optimized conventional PCR for AFB1 detection and a rapid, sensitive and simple screening Real-time PCR (qPCR) with SYBR Green and two pairs of primers targeting the aflR genes which involved aflatoxin biosynthesis. AFB1 contaminated maize samples were divided into three groups by the toxin concentration. Genomic DNA was extracted from those samples. The target genes for A. flavus were tested by conventional PCR and the PCR products were analyzed by electrophoresis. A conventional PCR was carried out as nested PCR to verify the gene amplicon sizes. PCR-RFLP patterns, obtained with Hinc II and Pvu II enzyme analysis showed the differences to distinguish aflatoxin-producing fungi. However, they are not quantitative and need a separation of the products on gel and their visualization under UV light. On the other hand, qPCR facilitates the monitoring of the reaction as it progresses. It does not require post-PCR handling, which reduces the risk of cross-contamination and handling errors. It results in a much faster throughout. We found that the optimal primer annealing temperature was $65^{\circ}C$. The optimized template and primer concentration were $1.5{\mu}L\;(50ng/{\mu}L)$ and $3{\mu}L\;(10{\mu}M/{\mu}L)$ respectively. SYBR Green qPCR of four genes demonstrated amplification curves and melting peaks for tub1, afIM, afIR, and afID genes are at $88.0^{\circ}C$, $87.5^{\circ}C$, $83.5^{\circ}C$, and $89.5^{\circ}C$ respectively. Consequently, it was found that the four primers had elevated annealing temperatures, nevertheless it is desirable since it enhances the DNA binding specificity of the dye. New qPCR protocol could be employed for the determination of aflatoxin content in feedstuff samples.

Mornitoring and Identification of Human Astrovirus from Groundwater in Korea Based on Highly Sensitive RT-nested PCR Primer Sets

  • Lee, Siwon;Bae, Kyung Seon;Park, Jihyun;Kim, Jin-Ho;Lee, Jin-Young;Choi, Jiwon;Park, Eung-Roh;You, Kyung-A
    • Biomedical Science Letters
    • /
    • v.27 no.4
    • /
    • pp.255-263
    • /
    • 2021
  • Human Astrovirus (HuAstV) is an important gastrointestinal pathogen that is frequently reported worldwide. Monitoring of contaminated groundwater has been suggested since HuAstV is transmitted through the fecal-oral route. This study developed a test method based on conventional reverse transcription (RT)-nested polymerase chain reaction (PCR) that involves SL® non-specific reaction inhibitor for unknown non-specific amplification taking place in the groundwater environment. An optimal method for detecting HuAstV in groundwater sample through analysis and comparison against conventionally reported method was also suggested. The developed method enabled the production of nested PCR amplicon of 630 nt, which is a sufficient length for similarity analysis based on sequencing and genotyping. Amplicons suspected to be HuAstV were amplified in two out of the twenty groundwater samples collected in Korea, presenting 99.77% and 99.73% similarity against HuAstV 1 strain lhar/2011/kor (JN887820.1) in sequencing, respectively. These amplicons were identified as HuAstV 1.

Rapid Detection of Serum HCV RNA by Combining Reverse Transcription and PCR without RNA Extraction

  • Jang, Jeong-Su;Lee, Kong-Joo
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.486-489
    • /
    • 1996
  • A simple, rapid, specific and sensitive method for the detection of serum hepatitis C virus (HCV) RNA using the reverse transcription-polymerase chain reaction (RT-PCR) technique without conventional RNA extraction was developed. HCV template RNA from serum was obtained by boiling the serum at $95^{\circ}C$ for 2 min, cooling rapidly in ice and removing the proteins by cetrifugation. RT-PCR amplifications including the reverse transcription and first PCR amplification were performed in one vessel containing both of reverse transcriptase and Taq DNA polymerase. The detection of HCV RNA from $10^{-3}{\mu}l$. serum was possible with this method. The suitability of this method for clinical analysis was evaluated by assaying HCV RNA in 225 patient samples including anti-HCV antibody negatives (13 samples) and positives (212 samples) by enzyme-linked immunosorbent assay test (ELISA). Detections of HCV RNA with this method were in 4 of 13 anti-HCV antibody negative samples (30.8%) and 95 of 212 positive samples (44.8%). The present method can be completed in 1 hr and has a wide range of application for the clinical utilities to determine the viral RNAS.

  • PDF

Application of Hot Start PCR Method in PCR-based Preimplantation Genetic Diagnosis

  • Kim, Sung-Ah;Kang, Moon-Joo;Kim, Hee-Sun;Oh, Sun-Kyung;Ku, Seung-Yup;Choi, Young-Min;Jun, Jong-Kwan;Moon, Shin-Yong
    • Journal of Genetic Medicine
    • /
    • v.9 no.1
    • /
    • pp.11-16
    • /
    • 2012
  • Purpose: To determine a method to improve the efficacy and accuracy of preimplantation genetic diagnosis (PGD) - polymerase chain reaction (PCR), we compared hot start PCR and conventional multiplex nested PCR. Materials and Methods: This study was performed with single lymphocyte isolated from whole blood samples that were obtained from two couples with osteogenesis imperfecta (OI). We proceeded with conventional multiplex nested PCR and hot start PCR in which essential reaction components were physically removed, and we compared the amplification rate, allele dropout rate and nonspecific products. Afterward, we used selective method for PGD. Results: In the two couples, the respective amplification rate were 93.5% and 80.0% using conventional multiplex nested PCR and 95.5% and 92.0% using hot start PCR. The respective mean allele dropout rates for the two couples were 42.0% and 14.0% with conventional multiplex nested PCR and 36.0% and 6.0% with hot start PCR. Conclusion: The results demonstrate that the hot start PCR procedure provides higher amplification rates and lower allele dropout rate than the conventional method and that it decreased the nonspecific band in multiplex nested PCR. The hot start method is more efficient for analyzing a single blastomere in clinical PGD.

Development of Reverse Transcriptase Polymerase Chain Reaction Primer Sets and Standard Positive Control Capable of Verifying False Positive for the Detection of Severe acute respiratory syndrome coronavirus 2

  • Cho, Kyu Bong
    • Biomedical Science Letters
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2021
  • Severe acute respiratory syndrome coronavirus (SARS-CoV2) is a major coronavirus that infects humans with human Coronavirus (HuCoV)-229E, HCoV-OC43, HCoV-HKU1, HCoV-NL63, Severe acute respiratory syndrome coronavirus (SARS-CoV) and Middle east respiratory syndrome coronavirus (MERS-CoV). SARS-CoV2 is currently a global pandemic pathogen. In this study, we developed conventional RT-PCR based diagnostic system for the detection of SARS-CoV2 which is relatively inexpensive but has high stability and a wide range of users. Three conventional RT-PCR primer sets capable of forming specific band sizes by targeting the ORF1ab [232 nucleotide (nt)], E (200 nt) and N (288 nt) genes of SARS-CoV2 were developed, respectively, and it were confirmed to be about 10~100 times higher detection sensitivity than the previously reported methods. In addition, a standard positive control that can generate specific amplicons by reacting with the developed RT-PCR primers and verify the false-positiv from contamination of the laboratory was produced. Therefore, the diagnostic system that uses the RT-PCR method is expected to be used to detect SARS-CoV2.

Adulteration of Caprine Milk Products by Bovine Milk in Korea (국내 시판 산양유제품 내 젖소 유성분의 혼입에 대한 조사 연구)

  • Jung, Tae-Hwan;Jeon, Woo-Min;Han, Kyoung-Sik
    • Journal of Dairy Science and Biotechnology
    • /
    • v.31 no.2
    • /
    • pp.127-131
    • /
    • 2013
  • The aim of this study was to investigate adulteration of caprine milk products by bovine milk using biomolecular techniques with bovine-specific primers for the mitochondrial cytochrome b gene. Polymerase chain reaction (PCR) and real-time PCR assays were applied to caprine milk products including infant formula, city milk, and fermented milk. The results indicated that six out of the eight caprine infant formula products tested contained bovine milk components. In addition, two of the three tested caprine city milk products and two caprine fermented milk products were shown to be adulterated with bovine milk. Conventional PCR results corroborated with results obtained by real-time PCR. This study demonstrates that DNA-based species identification procedures would be useful and applicable in routine examinations of the dairy industry to ensure the quality and safety of dairy foods.

  • PDF

Detection of HCV-RNA by Reverse Transcription Polymerase Chain Reaction Using Biotinylated and Radioiodinated Primers (역전사 중합효소 연쇄반응(RT-PCR)에 의한 HCV-RNA의 검출 : Biotin 및 방사성옥소 표지 Primer로 구성된 Kit의 이용)

  • Ryu, Jin-Sook;Moon, Dae-Hyuk;Cheon, Jun-Hong;Chung, Yoon-Young;Park, Hung-Dong;Chung, Young-Hwa;Lee, Young-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.220-226
    • /
    • 1994
  • This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.

  • PDF

Development of a diagnostic method for human enteric Adenovirus-41 with rapid, specific and high sensitivity using the loop-mediated isothermal amplification assay

  • Lee, Jin-Young;Rho, Jae Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.673-681
    • /
    • 2020
  • Human enteric Adenovirus 41 (HueAdV-41) is a major waterborne virus that causes human gastroenteritis and is classified as a viral group I double-strand DNA virus, Adenoviridae. HueAdV-41 has been detected with the polymerase chain reaction (PCR) in various samples such as ground water. However, the PCR-based diagnostic method has problems such as reaction time, sensitivity, and specificity. Thus, the loop-mediated isothermal amplification (LAMP) assay has emerged as an excellent method for field applications. In this study, we developed a LAMP system that can rapidly detect HueAdV-41 with high specificity and sensitivity. HueAdV-41 specific LAMP primer sets were tested through a specific, non-specific selection and sensitivity test for three prepared LAMP primer sets, of which only one primer set and optimum reaction temperature were selected. The developed LAMP primer set condition was confirmed as 63℃, and the sensitivity was 1 copy. In addition, to confirm the system, a LAMP positive reaction was developed with the restriction enzyme Taq I (T/GCC). The developed method in this study was more specific, rapid (typically within 2 - 3 hours), and highly sensitive than that of the conventional PCR method. To evaluate and verify the developed LAMP assay, an artificial infection test was done with five cDNAs from groundwater samples, and the results were compared to those of the conventional PCR method. We expect the developed LAMP primer set will be used to diagnose HueAdV-41 from various samples.