• Title/Summary/Keyword: Conventional Line

Search Result 2,393, Processing Time 0.029 seconds

Headway Analysis in Daejeon Nord section(Daejeon shunting yard-Daejeon station) which high speed train and conventional trains will be run (대전북(대전 조차장-대전역) 고속전철 연계 운행 구간의 운전시격 분석)

  • Kim, Yong-Gyu;Kim, Jong-Gi;Yu, Chang-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.810-813
    • /
    • 2003
  • The present headway on KNR(Korea National Railway) lines varies from 6 to 10 minutes depending on the each line and by the operation of High Speed line in 2004, the bottleneck would be expected within a few sections such as Daejeon-Daejeon shunting yard which will be the common mute between KTX(Korea Train Express) and conventional trains. Therefore, KNR would like to reduce the headway of the all lines by 4 minutes with the implementation of ERTMS/ETCS on-board system. Where ETCS(European Train Control system), the subsystem of ERTMS, is Automatic Train Protection system for safety train running. This study will be analyze expected braking distance and running time depending on characteristics of conventional passenger and freight trains and high speed train will be operated within electrified conventional line for comparing the headways of ATS(Automatic Train Stop) system and ETRMS/ETCS system within the Daejeon-Daejeon shunting yard section.

  • PDF

On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring (UHF 기술을 이용한 온라인 부분방전 모니터링)

  • Oh, Yong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

Improvement of Line Protection Methods by Dynamic Analysis on a FACTS-compensated transmission line (FACTS 보상 송전선의 동적 해석을 통한 송전선 보호 방안 개선)

  • Lim Jung-Uk;Runolfsson Thodur
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.573-579
    • /
    • 2005
  • Dynamic analysis of a transmission line which is compensated by a FACTS device such as STATCOM, SSSC and UPFC is carried out in this paper and the impacts on conventional line protection methods such as the DCPM (Differential Current Protection Method) and the DPM (Distance Protection Method) are reviewed. A refined DCRM is proposed to detect faults properly regardless of the FACTS operation. The proposed method is applied to a FACTS-compensated line with a variety of faults and is verified by simulation results. An adaptive DPM on a FACTS-compensated line was proposed previously in the literature. In order to emphasize the necessity of the modified DPM, the conventional DPM is applied to a FACTS-compensated system. Significant factors such as fault types, fault locations, and fault resistances as well as FACTS device types are considered for relaying setting.

Applicability Comparison of Transmission Line Parameter Extraction Methods for Busbar Distribution Systems

  • Hasirci, Zeynep;Cavdar, Ismail Hakki;Ozturk, Mehmet
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.586-593
    • /
    • 2017
  • Modeling busbar distribution system as a transmission line is an important subject of power line communication in the smart grid concept. This requires extraction of busbar RLGC parameters, accurately. In this study, a comparison is made between conventional and modified method for the aspect of optimum RLGC parameters extraction in the 1 MHz to 50 MHz frequency band. The usefulness of these methods is shown both in time and frequency-domain analysis. The frequency-domain analyzes show that the inherent power of modified method can eliminate the errors especially due to the discontinuities arise in conventional method. This makes the modeling approach of modified method more advantageous for the busbars due to its robustness against disturbances in the S-parameters measurements which cannot be eliminated with the calibration procedure. On the other hand, time-domain simulations show that the transmission line representation of the modified method is closer to physical reality by handling causality issues.

A new line to line fault location algorithm in distribution power networks using 3 phase direct analysis (3상회로의 직접해석에 의한 배전계통 선간단락 사고 고장거리 계산 알고리즘)

  • Jin, B.G.;Choi, M.S.;Lee, S.J.;Yoon, N.S.;Jung, B.T.;Lee, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.108-110
    • /
    • 2002
  • In this paper, a fault location algorithm is suggested for line to line faults in distribution networks. Conventional fault location algorithms use the symmetrical component transformation, a very useful tool for transmission network analysis. However, its application is restricted to balanced network only. Distribution networks are, in general, operated in unbalanced manners, therefore, conventional methods cannot be applied directly, which is the reason why there are few research results on fault location in distribution networks. Especially, the line to line fault is considered as a more difficult subject. The proposed algorithm uses direct 3-phase circuit analysis, which means it can be applied not only to balanced networks but also to unbalanced networks like distribution a network. The comparisons of simulation results between one of conventional methods and the suggested method are presented to show its effectiveness and accuracy.

  • PDF

Power Amplifier Design using λ/4 DGS(Defected Ground Structure) Bias Line (λ/4 DGS 바이어스 선로를 이용한 전력증폭기 설계)

  • 정시균;정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.924-931
    • /
    • 2002
  • In this paper, a new λ/4 bias transmission line that is added dumbbell-shaped defected ground structure(DGS) on ground plane of the conventional λ/4 bias transmission line is proposed. This DGS λ/4 bias transmission line maintains high characteristic impedance, but physical width is wider and length is shorter than that of the conventional bias line. If the proposed bias line is attached on signal transmission line, this bias line can reduces the $3^{rd}$ harmonic signal as well as the$2^{nd}$ harmonic signal. With harmonic reduction characteristics, efficiency and linearity of amplifier are improved. The proposed bias line is adopted in power amplifier on IMT-2000 base-station transmitting band. This paper presents several simulations and experimental results of DGS to show validity of the proposed power amplifier using the new λ/4 bias transmission line. Experimental results represent that the $3^{rd}$ harmonic signal is reduced about 26.5 dB and efficiency is improved about 9.1 % and IMD3 is improved 4.5 dB than the conventional structure.

Allowable Speed of Tilting Car in the Conventional Line (기존선의 선형조건을 고려한 틸팅차량의 허용속도 평가)

  • 유영화;엄주환;엄기영
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.4
    • /
    • pp.246-251
    • /
    • 2003
  • A quantitative analysis on the amounts of cant and lateral displacement of gravitational center due to the introduction of high-speed tilting car was carried out, based on the current alignment of the conventional line. In addition, the maximum allowable speed in curve and the level of improvement in maximum speed of tilting car were evaluated through the comparison with the maximum speed of locomotive. It was found that the tilting car produces an equivalent amount of cant, which corresponds to 47.5 % of current actual cant. This effect could be explained by the fact that 1.34 m, which is the height of gravitational center of tilting car from the rail level, is much lower than that of locomotive and thus guarantees much higher level of safety in curve. The equivalent amount of cant due to the lateral displacement of gravitational center followed by tilting in curve was 2.4 mm. It was small but not enough to be neglected and must be included in calculating the maximum speed in curve. It could be concluded that the 15 % speed-up of the conventional line is reasonable under the current condition of alignment.

On-line PD Monitoring Using UHF Technique (UHF 가술을 이용한 온라인 PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

A study on the Ride Comfort for High Speed Train on the High Speed Line/Conventional Line (고속선/기존선 연계운행에 대한 고속철도 차량의 승차감에 관한 연구)

  • 김영국;김석원;박찬경;김기환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.206-211
    • /
    • 2004
  • Recently, the ride comfort problem becomes increasingly important because of today's needs for train speedup. The concept of ride comfort is equivocal. Generally, it is defined as the body vibration. The commercial high-speed train must be run the compound line in Korea which is composed of high-speed line and conventional line. In this paper, the ride comfort has been reviewed by the various experimental methods when the high-speed train is operated on both lines. The results show that the high-speed train has no problems from the viewpoint of the comfort ride during the operation on both lines.

  • PDF

Analysis of Characteristics of Residential Distribution Line for PLC Modem Design (PLC 모뎀설계를 위한 옥내 배선 특성분석)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1524-1526
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper and Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and the averaged analysis data are shown in the tables. The measured results no different from the calculated values with using conventional formula due to the line arrangement neglected factors, complex permittivity, and etc. Also, this paper describes many kinds of lines and wiring figures of domestic construction. Finally, it is utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

  • PDF