• Title/Summary/Keyword: Conventional Line

Search Result 2,394, Processing Time 0.028 seconds

A Study on the Application of 3D Virtual Human in the prior stage of Design Works - With the emphasis on the determining design layout of a forklift truck (디자인 초기단계에서의 3차원 가상인간(Virtual Human) 활용에 관한 연구 - 지게차 레이아웃 결정 단계를 중심으로)

  • 김관명
    • Archives of design research
    • /
    • v.12 no.4
    • /
    • pp.294-303
    • /
    • 1999
  • With the breakthrough development of computing environment, the design phases have been changed a lot nowadays. In the case of prior phases of transportation design such as cars and forklift-trucks design, designers have depended on surveys and 2D line drawings for fixing a product layout and extracting ergonomic data. In this method, designers don't meet only the problem of reliability of measuring data but also, the problems of unknown situation of operators' fatigue and comfort in work situation. In these methods, it has much less creditability to have a 2D human model to check the real world motion due to the limitation of the 3 Dimension. Even though with a 2D human model, perfect layout is determined, it is still difficult to measure about comfort and fatigue for a user because it measuring an analysing method is static. The development of computer hardware and software have not only changed the flow in the social-wide range but also immerged design into Virtual Environment. In conventional design method, visualization and data transferring have been the main issues but, in virtual environment, determining of design layout and analysing ergonomic data with sophisticated feeling about comfort and fatigue are possible by using 3D virtual human. In this study, the general characteristics of virtual environment was discussed and the possibility of digital process of design was treated. For these studies, layout design for forklift-trucks was tested. Eventually, the merits of each design phase applied virtual environment are discussed.

  • PDF

A STUDY ON COMPARISON OF VARIOUS KINDS OF CLASSII AMALGAM CAVITIES USING FINITE ELEMENT METHOD (유한요소법을 이용한 수종 2급 아말감 와동의 비교연구)

  • Seok, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.432-461
    • /
    • 1995
  • The basic principles in the design of Class II amalgam cavity preparations have been modified but not changed in essence over the last 90 years. The early essential principle was "extension for prevention". Most of the modifications have served to reduce the extent of preparation and, thus, increase the conservation of sound tooth structure. A more recent concept relating to conservative Class II cavity preparations involves elimination of occlusal preparation if no carious lesion exists in this area. To evaluate the ideal ClassII cavity preparation design, if carious lesion exists only in the interproximal area, three cavity design conditions were studied: Rodda's conventional cavity, simple proximal box cavity and proximal box cavity with retention grooves. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method. Linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B option, Gap option and R option model) were developed. B option model was assumed perfect bonding between the restoration and cavty wall. Gap option model(Gap distance: $2{\mu}m$) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). R option model was assumed non-connection between the restoration and cavty wall. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as followed. 1. Rodda's cavity form model showed greater amount of displacement with other two models. 2. The stress and strain were increased on the distal marginal ridge and buccopulpal line angle in Rodda's cavity form model. 3. The stress and strain were increased on the central groove and a part of distal marginal ridge in simple proximal box model and proximal box model with retention grooves. 4. With Gap option, Rodda's cavity form model showed the greatest amount of the stress on distal marginal ridge followed by proximal box model with retention grooves and simple proximal box model in descending order. 5. With Gap option, simple proximal box model showed greater amount of stress on the central groove with proximal box model with retention grooves. 6. Retention grooves in the proximal box played the role of supporting the restorations opposing to loads.

  • PDF

Development of X-ray Detector using Liquid Crystal with Front Light (전면광원(Front Light)을 적용한 액정 X선 검출기 개발)

  • Rho, Bong Gyu;Baek, Sam Hak;Kang, Seok Jun;Lee, Jong Mo;Bae, Byung Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.831-840
    • /
    • 2019
  • The X-ray detector by liquid crystal with front light was proposed and verified by a X-ray image. The proposed detector utilizes the visible light instead of the electric signal by transistor. Therefore, it shows low noise and can be fabricated at low cost. The liquid crystal detector uses the orientation change of the liquid crystal molecule by conductivity change of the photoconductive layer. We can get the X-ray image from the transmitted light through the liquid crystal. The X-ray dose was calibrated from the measured transmittance of the visible light after comparison to the reference transmittance curve of the liquid crystal. The amorphous Se was used for photo con ducting layer and parylene was used for the liquid crystal alignment instead of the conventional alignment layer which needs high-temperature process over 200℃. The proposed X-ray detector can decrease the X-ray dose by high sensitivity which was verified by simulation. After the fabrication of the X-ray detector, the X-ray image was obtained as a function of the bias voltage to the liquid crystal. 10 lines/mm resolution was obtained from the line pattern and we will apply it to the 17inch diagonal liquid crystal X-ray detector with 3π retardation.

A Charge Pump Design with Internal Pumping Capacitor for TFT-LCD Driver IC (내장형 펌핑 커패시터를 사용한 TFT-LCD 구동 IC용 전하펌프 설계)

  • Lim, Gyu-Ho;Song, Sung-Young;Park, Jeong-Hun;Li, Long-Zhen;Lee, Cheon-Hyo;Lee, Tae-Yeong;Cho, Gyu-Sam;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1899-1909
    • /
    • 2007
  • A cross-coupled charge pump with internal pumping capacitor, witch is advantages from a point of minimizing TFT-LCD driver IC module, is newly proposed in this paper. By using a NMOS and a PMOS diode connected to boosting node from VIN node, the pumping node is precharged to the same value each pumping node at start pumping operation. Since the lust-stage charge pump is designed differently from the other stage pumps, a back current of pumped charge from charge pumping node to input stage is prevented. As a pumping clock driver is located the font side of pumping capacitor, the driving capacity is improved by reducing a voltage drop of the pumping clock line from parasitic resistor. Finally, a layout area is decreased more compared with conventional cross-coupled charge pump by using a stack-MIM capacitors. A proposed charge pump for TFT-LCD driver IC is designed with $0.13{\mu}m$ triple-well DDI process, fabricated, and tested.

Speckle Noise Removal by Rank-ordered Differences Diffusion Filter (순위 차 확산 필터를 이용한 스페클 잡음 제거)

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.1
    • /
    • pp.21-30
    • /
    • 2009
  • The purposes of this paper are to present a selection method of neighboring pixels whose local statistics are similar to the center pixel and combine the selection result with mean curvature diffusion filter to reduce noises in remote sensed imagery. The order of selection of neighboring pixels is critical, especially for finding a pixel belonging to the homogeneous region, since the statistics of the homogeneous region vary according to the selection order. An effective strategy for selecting neighboring pixels, which uses rank-order differences vector obtained by computing the intensity differences between the center pixel and neighboring pixels and arranging them in ascending order, is proposed in this paper. By using region growing method, we divide the elements of the rank-ordered differences vector into two groups, homogeneous rank-ordered differences vector and outlier rank-ordered differences vector. The mean curvature diffusion filter is combined with a line process, which chooses selectively diffusion coefficient of the neighboring pixels belonging into homogeneous rank-ordered differences vector. Experimental results using an aerial image and a TerraSAR-X satellite image showed that the proposed method reduced more efficiently noises than some conventional adaptive filters using all neighboring pixels in updating the center pixel.

Adaptive Filter Design for Eliminating Baseline Wandering Noise of Electrocardiogram (심전도 기저선 흔들림 잡음 제거를 위한 적응형 필터 설계)

  • Choi, Chul-Hyung;Rahman, MD Saifur;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • The Journal of Korean Institute of Information Technology
    • /
    • v.15 no.12
    • /
    • pp.157-164
    • /
    • 2017
  • Mobile ECG signal measurement is a technique to measure small signals of several mV, and many studies have been conducted to remove noise including wandering scheme. Removal of the equipotential line noise caused by shaking or movement of the electrode cable is one of the core research contents for the electrocardiogram measurement. In this study, we proposed a modified step-size of combined NLMS(normalized least squares) and DLMS(delayed least squares) adaptive filter to eliminate baseline noise from ECG signals. The proposed method mainly adjusts initial filter step-size to reduce distortion of original ECG signals characteristic after eliminating baseline noise. The modified filter step-size is scaled by filter order size and distortion minimization factor. This method is suitable for portable ECG device with a small processor and less power consumption. This technique also decreases computation time which is essential for real-time filtering. The proposed filter also increase the signal to noise ratio (SNR) compared to conventional NLMS filter.

Long-range multiple-input-multiple-output underwater communication in deep water (심해에서의 장거리 다중입출력 수중통신)

  • Kim, Donghyeon;Kim, Daehwan;Kim, J.S.;Hahn, Joo Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.5
    • /
    • pp.417-427
    • /
    • 2021
  • Long-range communication in deep waters must overcome the low data rate due to limited bandwidth. This paper presents the performance of Multiple-Input-Multiple-Output (MIMO) system to increase the data rate. In MIMO system, communication performance is degraded by crosstalk between users and an adaptive passive Time Reversal Processing (TRP) is widely used to eliminate this. In October 2018, long-range underwater acoustic communication experiment was conducted in deep water (1,000 m ~) off the east of Pohang, South Korea. During the experiment, a vertical line array was utilized and communication signals modulated by binary phase shift keying and quadrature phase shift keying with a symbol rate of 512 sps were transmitted. To generate MIMO communication signals, received signals from ranges of 26 km and 30 km is synthesized. Compared to the conventional passive TRP, the adaptive passive TRP eliminates the crosstalk between users and achieves error-free performance with an increase of output signal-to-noise ratio. Therefore, two users separated by 4 km in range achieves an aggregate data rate of 1,024 symbols/s.

Analysis of interest in implant using a big data: A web-based study (빅 데이터를 이용한 임플란트에 대한 관심도 분석: 웹 기반 연구)

  • Kong, Hyun-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.164-172
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the level of interest that common Internet users have in dental implant using a Google Trends, and to compare the level of interest with big data from National Health Insurance Service. Materials and methods: Google Trends provides a relative search volume for search keywords, which is the average data that visualizes the frequency of searches for those keywords over a specific period of time. Implant was selected as the search keyword to evaluate changes in time flows of general Internet users' interest from 2015 to 2019 with trend line and 6 month moving average. Relative search volume for implant was analyzed with the number of patients who received National Health Insurance coverage for implant. Interest in implant and conventional denture was compared and popular related search keywords were analyzed. Results: Relative search volume for implant has increased gradually and showed a significant positive correlation with the total number of patients (P<.01). Interest in implant was higher than denture for most of the time. Keywords related to implant cost were most frequently observed in all years and related search on implant procedure was increasing. Conclusion: Within the limitations of this study, the public interest in dental implant was gradually increasing and specific areas of interest were changing. Web-based Google Trends data was also compared with traditional data and significant correlation was confirmed.

Modeling of Material Properties of Fiber-Reinforced High Strength Concrete (섬유 보강 고강도 콘크리트의 재료 특성 모델링)

  • Yang, In-Hwan;Park, Ji-Hun;Choe, Jeong-Seon;Joh, Changbin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.349-356
    • /
    • 2018
  • In this study, material properties of steel fiber reinforced high strength concrete (FRHSC) with the compressive strength of about 120MPa were modeled. Steel fiber content of 1.0%, 1.5%, and 2.0% was considered as experimental variable. First of all, compressive strength tests were carried out to determine compressive characteristics of concrete, and compressive stress-strain curves were modeled. For conventional concrete with moderate compressive strength, the stress-strain curves are in the form of parabolic curves, but in the case of high strength concrete reinforced with steel fiber, the curves increase linearly in the form of the straight line. In addition, to understand the tensile properties of FRHSC, the crack mouth opening displacement (CMOD) test was performed, and the tensile stress-CMOD curve was calculated through inverse analysis. When the steel fiber content increased from 1.0% to 1.5%, there was a significant difference of tensile strength. However, when the amount of steel fiber was increased from 1.5% to 2.0%, there was no significant difference of tensile strength, which might result from the poor dispersion and arrangement of steel fiber in concrete.

Walnut phenolic extracts reduce telomere length and telomerase activity in a colon cancer stem cell model

  • Shin, Phil-Kyung;Zoh, Yoonchae;Choi, Jina;Kim, Myung-Sunny;Kim, Yuri;Choi, Sang-Woon
    • Nutrition Research and Practice
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: Telomeres are located at the chromosomal ends and progressively shortened during each cell cycle. Telomerase, which is regulated by hTERT and c-MYC, maintains telomeric DNA sequences. Especially, telomerase is active in cancer and stem cells to maintain telomere length for replicative immortality. Recently we reported that walnut phenolic extract (WPE) can reduce cell viability in a colon cancer stem cell (CSC) model. We, therefore, investigated the effect of WPE on telomere maintenance in the same model. MATERIALS AND METHODS: $CD133^+CD44^+$ cells from HCT116, a human colon cancer cell line, were sorted by Fluorescence-activated cell sorting (FACS) and treated with WPE at the concentrations of 0, 10, 20, and $40{\mu}g/mL$ for 6 days. Telomere lengths were assessed by quantitative real-time PCR (qRT-PCR) using telomere specific primers and DNA extracted from the cells, which was further adjusted with single-copy gene and reference DNA ($ddC_t$). Telomerase activity was also measured by qRT-PCR after incubating the PCR mixture with cell protein extracts, which was adjusted with reference DNA ($dC_t$). Transcriptions of hTERT and c-MYC were determined using conventional RT-PCR. RESULTS: Telomere length of WPE-treated cells was significantly decreased in a dose-dependent manner ($5.16{\pm}0.13$ at $0{\mu}g/mL$, $4.79{\pm}0.12$ at $10{\mu}g/mL$, $3.24{\pm}0.08$ at $20{\mu}g/mL$ and $3.99{\pm}0.09$ at $40{\mu}g/mL$; P = 0.0276). Telomerase activities concurrently decreased with telomere length ($1.47{\pm}0.04$, $1.09{\pm}0.01$, $0.76{\pm}0.08$, and $0.88{\pm}0.06$; P = 0.0067). There was a positive correlation between telomere length and telomerase activity (r = 0.9090; P < 0.0001). Transcriptions of both hTERT and c-MYC were also significantly decreased in the same manner. CONCLUSION: In the present cell culture model, WPE reduced telomere maintenance, which may provide a mechanistic link to the effect of walnuts on the viability of colon CSCs.