• Title/Summary/Keyword: Conventional Ground Impedance

Search Result 64, Processing Time 0.026 seconds

ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed (침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정)

  • Lim, Y.G.;Kim, K.K.;Park, K.S.;Jeong, D.U.
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF

A Conical-Cylindrical Monopole Antenna

  • Jeong, Hye-Mi;Park, Seong-Bae;Kim, Choon-Won;Sodnomtseren, Ononchimeg;Bang, Jai-Hoon;Ahn, Biemg-Chearl
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.3
    • /
    • pp.138-146
    • /
    • 2007
  • In this paper, a monopole antenna of conical-cylindrical compound shape is presented. The conventional circular conical monopole antenna is modified by placing a cylinder at the top of the inverted cone. The cylindrical portion is useful in the wide band impedance matching, in adjusting the antenna gain in the horizontal direction, and in reducing the cone diameter. The dependence of the antenna performance on various geometric parameters is investigated using a commercial electromagnetic simulation software, from which an optimum design of the antenna is derived. The diameter of the circular ground plane is minimized to 115 wavelength at the lowest operating frequency. The antenna proposed in this study shows a reflection coefficient less than -10 dB and a 1${\sim}$6 dBi gain over 3${\sim}$20 GHz frequencies. The antenna shows a circular-symmetric radiation pattern in the horizontal plane and a null-free pattern in the vertical direction over the whole operating frequency range.

Analysis of Receiving Responses for a Bistatic Ground-Penetrating Radar System by Using Equivalent Network Model (등가회로망 모델을 이용한 Bistatic 지하탐사 레이더 시스템의 수신응답 해석)

  • 현승엽
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.6
    • /
    • pp.404-404
    • /
    • 2000
  • The receiving responses of a bistatic GPR system are analyzed by using three-dimensional FDTD method and equivalent network model. The conventional delta-gap feed model may be inaccurate because of neglecting the impedance matching characteristics between the antenna and the transmission line. In this paper, the feed model is improved by considering the physical characteristics of the actual GPR. The actually received voltage is calculated by employing the equivalent network model in angular frequency-domain, which is composed by using the results of three-dimensional FDTD analysis for an actual bistatic GPR system. The validity of the presented model is assured by showing the convergence of the computed results to the measured data.

Analysis of Receiving Responses for a Bistatic Ground-Penetrating Radar System by Using Equivalent Network Model (등가회로망 모델을 이용한 Bistatic 지하탐사 레이더 시스템의 수신응답 해석)

  • Hyeon, Seung-Yeop;Kim, Sang-Uk;Kim, Se-Yun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.6
    • /
    • pp.44-53
    • /
    • 2000
  • The receiving responses of a bistatic GPR system are analyzed by using three-dimensional FDTD method and equivalent network model. The conventional delta-gap feed model may be inaccurate because of neglecting the impedance matching characteristics between the antenna and the transmission line. In this paper, the feed model is improved by considering the physical characteristics of the actual GPR. The actually received voltage is calculated by employing the equivalent network model in angular frequency-domain, which is composed by using the results of three-dimensional FDTD analysis for an actual bistatic GPR system. The validity of the presented model is assured by showing the convergence of the computed results to the measured data.

  • PDF

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

Effects of the Case Currents of Mobile Phone on the Antenna Characteristics (휴대폰 몸체 전류 변화를 이용한 안테나 특성 연구)

  • Kim, Jae-Hee;Park, Se-Hyun;Kim, Young-Eil;Park, Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.136-142
    • /
    • 2007
  • We present two effects of the case currents of a mobile phone on changing the radiation pattern of a PIFA and on enhancing the bandwidth of the monopole antenna. In order to change the radiation pattern, a modification of the ground plane is suggested to suppress the back radiation. The resulting gain is higher than that of a conventional PIFA by 0.5 dB. For enhancing the bandwidth, two parasitic metallic lines are added in the direction orthogonal to the monopole to induce double resonances. The impedance bandwidth of the proposed structure is 341 MHz, which is nearly twice of that of the conventional monopole.

Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method (동적 시정수 기반 고성능 절연 저항 계산 기법)

  • Son, Gi-Beom;Hong, Jong-Phil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.8
    • /
    • pp.1058-1063
    • /
    • 2020
  • This paper presents a new insulation resistance calculation technique to prevent electric shock and fire accidents due to the dielectric breakdown in the primary insulation section of the IT ground system. The solar power generation market is growing rapidly due to the recent expansion of renewable energy and energy storage systems, but as the insulation is destroyed and fire accidents frequently occur, a device for monitoring the insulation resistance state is indispensable to the IT grounding method. Compared to the conventional algorithm that use a method of multiplying a time constant to a fixed coefficient, the proposed insulation resistance calculation method has a fast response time and high accuracy over a wide insulation resistance range by applying a different coefficient according to the values of the insulation impedance. The proposed dynamic time constant based insulation resistance calculation technique reduces the response time by up to 39.29 seconds and improves the error rate by 20.11%, compared to the conventional method.

Size Reduction of a Quasi Class-E High Power Amplifier Using Defected Ground Structure (결함 접지 구조를 이용한 유사 E급 전력 증폭기의 소형화)

  • Choi, Heung-Jae;Jeong, Yong-Chae;Lim, Jong-Sik;Jung, Young-Bae;Eom, Soon-Young;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • In this work, a reduced size 20W quasi class-E Power Amplifier(PA) with defected ground structure load-network is presented for WCDMA base station application. Harmonic impedances required for the class E operation are satisfied by applying the dumbbell and the asymmetric spiral DGS. Open impedance for 2nd harmonic frequency which has the highest power and nearly short impedances for other higher order harmonics are provided by the proposed DGS load-network. The maximum Power Added Efficiency(PAE) of 70.2 % at the output power of 43.1 dBm with the saturated power gain of 12.7 dB is achieved by the proposed quasi class-E PA, which is comparable to the performance of the reference class-E PA. Total size of the proposed class-E PA is only $50{\times}50\;mm^2$ and much smaller than the conventional class-E PA that is loaded with a number of open stubs.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

Design of Miniaturized Broadband Parasitic Patch Antenna Using Reduced Size Main Patch with U-Shaped Parasitic Patches (폭이 좁아진 주 패치와 U자 형태의 기생 패치를 이용한 소형화된 광대역 기생 패치 안테나 설계)

  • Wi, Sang-Hyuk;Kim, Woo-Tae;Hong, Young-Pyo;Yuk, Jai-Rim;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.389-397
    • /
    • 2007
  • This paper proposes miniaturized broadband parasitic patch antenna. The proposed antenna consists of a probe fed reduced size main patch and U-shaped parasitic patches. The parasitic patches are incorporated to the radiating edges of the main patch to miniaturize the antenna size. The broadband impedance matching can be achieved by either E-plane or H-plane electromagnetic coupling between main patch and parasitic elements. The size of radiating elements is $18{\times}17.6\;mm^2$ and the overall dimension of designed antenna with substrate and ground plane is $25{\times}30{\times}4\;mm^3$. The fabricated antenna on a FR4 substrate shows two resonant frequencies(5.12 GHz and 6.08 GHz) with 27.3 %(1.5 GHz) fractional bandwidth at 5.5 GHz center frequency. The calculated and measured radiation patterns are almost similar to conventional patch antenna.