• 제목/요약/키워드: Convective heat transfer coefficients

검색결과 124건 처리시간 0.029초

비정상 후류가 선형터빈익렬의 유동 및 열전달에 미치는 영향에 관한 연구 (Influence of the Unsteady Wake on the Flow and Heat Transfer in a Linear Turbine Cascade)

  • 윤순현;심재경;김동건
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.164-170
    • /
    • 2001
  • The influence of unsteady wake on the flow and heat transfer characteristics in a four-vane linear cascade was experimentally investigated. The unsteady wake was generated with four rotating rectangular plates located upstream of the cascade. Tested inlet Reynolds number based on chord length was set to 66,000 by controlling free-stream velocity. A hot-wire anemometer system was employed to measure turbulent velocity components. For the convective heat transfer coefficients measurement on turbine blade surface, thermochromic liquid crystal and gold film Intrex were used. It was found that the unsteady wake enhances the turbulent motion in the cascade passage and accordingly promotes the development and transition of boundary layer. It was found that the heat transfer coefficients on the blade surface increase as the plate rotating speed increases. However, the increasing of heat transfer coefficients is not significant in the case that Strouhal number is higher than 0.503.

가스터빈 블레이드 끝단 형상에 따른 블레이드 끝단 및 그 주변에서의 열전달 계수 변화 (Effect of Blade Tip Geometry on Heat Transfer Coefficients on Gas Turbine Blade Tips and Near Tip Regions)

  • 곽재수
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.328-336
    • /
    • 2006
  • Detailed heat transfer coefficient distributions an two. types of gas turbine blade tip, plane tip and squealer tip, were measured using a hue-detection base transient liquid crystals technique.. The heat transfer coefficients an the shroud and near tip regions of the pressure and suction sides af the blade were also. measured. The heat transfer measurements were taken at the three different tip gap clearances af 1.0%, 1.5%, and 2.5% of blade span. Results shaw the overall heat transfer coefficients on the tip and shroud with squealer tip blade were lower than those with plane tip blade. By using squealer tip, however, the reductions af heat transfer coefficients near the tip regions of the pressure and suction sides were nat remarkable.

전자기기 냉각용 압전팬의 열전달 향상 (Heat Transfer Enhancement of a Piezoelectric Fan for Cooling of Electronic Devices)

  • 김은필;윤정인
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.14-21
    • /
    • 2014
  • Piezoelectric fans are thin elastic beams whose vibratory motion is actuated by means of a piezoelectric material bonded to the beam. These fans have found use as a means to enhance convective heat transfer while requiring only small amounts of power. This study presents new types of models with heat sink having air passage and investigates experimentally their heat transfer characteristics. From the comparison results for four models, the heat transfer coefficients of model 1 are approximately 44~66% higher than those of the reference model 0. The model 1 show the best overall performance about heat transfer and cooling capability. As shown in above results, it is necessary to design the heat sink with air pass for cooling of electronic devices, in order to increase the convective heat transfer coefficient of a piezoelectric fan for electronic cooling.

An Experimental Investigation of Heat Transfer in Forced Convective Boiling of R 134a, R 123 and R 134a/R 123 in a Horizontal Tube

  • Lim, Tae-Woo;Kim, Jun-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권3호
    • /
    • pp.513-525
    • /
    • 2004
  • This paper reports an experimental study on flow boiling of pure refrigerants R l34a and R l23 and their mixtures in a uniformly heated horizontal tube. The flow pattern was observed through tubular sight glasses with an internal diameter of 10㎜ located at the inlet and outlet of the test section. Tests were run at a pressure of 0.6 MPa in the heat flux ranges of 5-50㎾/㎡, vapor quality 0-100 percent and mass velocity of 150-600㎏/㎡s. Both in the nucleate boiling-dominant region at low quality and in the two-phase convective evaporation region at higher quality where nucleation is supposed to be fully suppressed, the heat transfer coefficient for the mixture was lower than that for an equivalent pure component with the same physical properties as the mixture. The reduction of the heat transfer coefficient in mixture is explained by such mechanisms as mass transfer resistance and non-linear variation in physical properties etc. In this study, the contribution of convective evaporation, which is obtained for pure refrigerants under the suppression of nucleate boiling, is multiplied by the composition factor by Singal et al. (1984). On the basis of Chen's superposition model, a new correlation is presented for heat transfer coefficients of mixture.

수평 평활관내에서 비공비혼합냉매의 강제대류 증발열전달 (Forced Convective Evaporating Heat Transfer of Non-azeotropic Refrigerant Mixtures in a Horizontal Smoothed Tube)

  • 박기원;오후규
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.225-233
    • /
    • 1995
  • Experiments were performed to investigate the heat transfer characteristics of nonazeotropic mixture R-22+R-114 in a heat pump system. The ranges of parameter, such as heat flux, mass flow rate, and quality were $8,141{\sim}32,564W/m^2$, 24~58kg/h, and 0~1, respectively. The overall compositions of the mixtures were 50 and 100 per-cent of R-22 by weight for R-22+R-114 mixture. The results indicated that there were distinct different heat transfer phenomena between the pure substance and the mixture. In case of pure refrigerant the heat transfer rates for cooling were strongly dependent upon quality of the refrigerant. Overall evaporating heat transfer coefficients for the mixture were somewhat lower than pure R-22 values in the forced convective boiling region. For a given flow rate, the heat transfer coefficient at the circumferential tube wall(top, side, and bottom of the test tube) for R-22/R-114(50/50wt%)mixture, however, was higher than for pure R-22 at side and bottom of the tube. Furthermore, a prediction for the evaporating heat transfer coefficient of the mixtures was developed based on the method of Yoshida et.al.'s. The resulting correlation yielded a good agreement with the data for the refrigerant mixtures.

  • PDF

수평 직사각 덕트 내 임계점 부근 물의 대류열전달 특성 (Convective Heat Transfer to Water near the Critical Region in Horizontal Rectangular Ducts)

  • 이상호
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.477-485
    • /
    • 2012
  • 수평 덕트 내 임계점부근의 유체 유동 및 열전달특성은 중력과 함께 임계영역에서의 열역학 및 전달 물성치의 많은 변화와 직접적으로 연관되어 있다. 본 연구에서는 수평 직사각 덕트 내 임계점부근의 물에 대한 대류열전달특성을 전산해석을 통하여 분석하였다. 이를 통해 국부적인 열전달계수와 유속, 온도, 그리고 물성치분포를 포함한 대류열전달특성에 대해 임계점 근접효과와 함께 비교하였다. 벽으로부터의 열전달에 따른 유체 밀도감소로 덕트 내 유동방향으로의 유속증가와 함께 유체가 액체에서 기체 같은 상태로 천이하는 형태의 유동장특성을 보여준다. 덕트의 윗면, 옆면, 그리고 아래면 각각의 국부적인 열전달계수분포에 큰 차이가 있으며 준임계점 온도부근에서 난류전달특성의 향상으로 열전달계수의 최대치에 이르게 된다. Nu 수는 덕트 내 압력과 종횡비에 영향을 받으며 임계압에 가까워질수록 최대 Nu 수는 급격히 증가하게 된다. 이와 함께 기존의 열전달상관식을 통한 결과와 예측된 Nu 수 분포를 비교하였다.

가스터빈 베인 끝벽의 열전달 특성 및 정압분포 측정 (Measurement of Heat Transfer and Pressure Distributions on a Gas Turbine Vane Endwall)

  • 이용진;신소민;곽재수
    • 한국항공운항학회지
    • /
    • 제14권2호
    • /
    • pp.33-38
    • /
    • 2006
  • Heat transfer coefficients and static pressure distributions on a gas turbine vane endwall were experimentally investigated in a 5 bladed linear cascade. The Reynolds number based on an axial chord length and the cascade exit velocity was 500,000. Both heat transfer and pressure measurements on the vane endwall were made at the two different turbulence intensity levels of 6.8% and 10.8%. Detailed heat transfer coefficient distributions on the vane endwall region were measured using a hue detection based transient liquid crystals technique. Results show various regions of high and low heat transfer coefficients on the vane endwall surface due to several types of secondary flows and vortices. Heat transfer coefficient and endwall static pressure distributions showed similar trends for both turbulence intensity, however, the averaged heat transfer coefficients for higher turbulence intensity case was higher than the lower turbulence intensity case by 15%.

  • PDF

해석방법 및 연소가스특성 적용에 따른 로켓 노즐 대류열전달계수의 매개변수적 비교 고찰 (Parametric comparative study of Rocket Nozzle Convective Heat Transfer Coefficient Application of Combustion gas characteristic and Method of Analysis)

  • 김용구;배주찬;김진옥
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.651-663
    • /
    • 2017
  • $30^{\circ}-15^{\circ}$ 노즐의 실험결과와 FLUENT, 경계층 적분법, Bartz 예측식을 사용하여 수치계산한 대류열전달계수를 서로 비교하였다. 또한 NASA HIPPO 노즐을 대상으로 FLUENT와 경계층 적분법을 이용하여 연소가스특성에 따른 대류열전달계수를 계산하고 압력과의 상관관계를 비교하였다. NASA HIPPO 노즐을 대상으로 열반응 해석을 실시하여 연소가스특성에 따른 삭마두께와 숯 깊이를 비교하였다.

  • PDF

원형관-평판휜 형상의 밀집형 열교환기 내 공기 측대류열전달특성에 대한 수치해석 (Numerical Analysis for the Air-Side Convective Heat Transfer Characteristics in a Compact Heat Exchanger with Circular Tubes and Continuous Plate Fins)

  • 모정하;이상호
    • 대한기계학회논문집B
    • /
    • 제31권12호
    • /
    • pp.994-1001
    • /
    • 2007
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in a compact heat exchanger with circular tubes and continuous plate fins. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental correlations. Three models of standard and RNG $k-{\varepsilon}$, and Reynolds stress are applied for turbulence model applicability. Predicted heat transfer coefficient from the models of standard and RNG $k-{\varepsilon}$ are very close to those of the heat transfer correlations while there are relatively large difference, more than 17 percentage in the result from the Reynolds stress model. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested.

Evaporating Heat Transfer Characteristics of R-l34a in a Horizontal Smooth Channel

  • Pamitran, A.S.;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권4호
    • /
    • pp.156-165
    • /
    • 2006
  • Convective boiling heat transfer coefficients were measured in a horizontal minichannel with R-l34a. The test section was made of stainless steel tube with an inner diameter of 3.0 mm and a length of 2m. It was uniformly heated by applying electric current directly to the tube. Local heat transfer coefficients were obtained for heat fluxes from 10 to $40kW/m^2$, mass fluxes from 200 to $600kgT/m^2s$, qualities up to 1.0, and the inlet saturation temperature of $10^{\circ}C$. The experimental results were mapped on Wojtan et $al.'s^(7)$ and Wang et $al.'s^(8)$ flow pattern maps. The nucleate boiling was predominant at low vapor quality whereas the convective boiling was predominant at high vapor quality. Laminar flow appeared in the flow with minichannel. The experimental results were compared with six existing two-phase heat transfer coefficient correlations. A new boiling heat transfer coefficient correlation based on the superposition model for refrigerants was developed with mean and average deviations of 10.39% and -3.66%, respectively.