• 제목/요약/키워드: Controlled Rest

검색결과 118건 처리시간 0.025초

하복부 수술에서 경막외 Bupivacaine과 Fentanyl에 의한 선행진통법이 술후 통증관리에 미치는 효과 (Effects of Preemptive Analgesia by Epidural Bupivacaine and Fentanyl on Postoperative Pain Control in Lower Abdominal Surgery)

  • 이준학;김인령;윤채식;정은배;이기남;문준일
    • The Korean Journal of Pain
    • /
    • 제10권2호
    • /
    • pp.185-190
    • /
    • 1997
  • Background: Preemptive analgesia is an antinociceptive treatment that prevents the establishment of altered central processing which amplifies postoperative pain. A controversy exists over the effectiveness and clinical value of preemptive analgesia. We studied whether epidural bupivacaine and fentanyl prior to surgery could possibly affect postoperative pain and analgesic demands, as compared to administration of same at end of surgery. Methods: Forty patients scheduled for lower abdominal surgery were randomly assigned to one of two groups and prospectively studied in a double-blind method. Group 1(n=20) received epidural injection of 15 ml bupivacaine 0.25% with fentanyl 100 y g before surgery while group 2(n=20) received the same injection at the end of their surgery respectively. Postoperative analgesia consisted of basal plus patient-controlled mode of epidural bupivacaine and fentanyl from PCA system. Postoperative visual analog pain scores(VAPS), analgesics consumption, supplementary analgesics requirement and side effects were assessed for 3 postoperative days. Results: There were no significant difference in analgesics requirement and pain scores, at any time, during rest or after movement, in measurement between the groups. Conclusions: We conclude no clinical value of effectiveness in administering epidural bupivacaine-fentanyl before surgery as compared to administration after surgery.

  • PDF

중부한국의 하록림 밑 관목층 구성종의 미분포와 종간상관 (Pattern and Association within Shrub Layer under Summer Green Forest in Central Korean Peninsula)

  • 오계칠
    • Journal of Plant Biology
    • /
    • 제15권1호
    • /
    • pp.33-41
    • /
    • 1972
  • Nine shrub layer communities under two relatively well conserved natural summer green forests in the central region of Korean Peninsula were studied for the pattern of stem distribution in terms of Greig-Smith's multiple split-plot experiment and for the association between the population of the two main species in terms of Kershaw's covariance analysis respectively. Four contiguous belt transects, $4{\times}64m size with 1{\times}1m$ basic unit, were set in each shrub layer communities. Significant primary clumps with $1{\times}1m or 1{\times}2m$ dimension wer observed consistently throughout the nine study sites. The primary clumps themselves were significantly distributed either regularly or at random. The association between the two principal species of each shrub layer is highly significantly either positive or negative in $1{\times}1m or 1{\times}2m$ dimension. As the plot size increases from $1{\times}1m to 8{\times}8m$ the associational trends were changed from negative to positive direction in one forests. But the change from positive to negative direction and the consistent negative association were also observed from the other forest. All of the association trends were observed only from $1{\times}1m to 4{\times}4m$ dimension. These results are suggestive that the distributional pattern of the shrub layer species under the summer green forest is simple mosaic fashioned with $1{\times}1m or 1{\times}2m$ dimension. The rest of the principal species are located in that matrix. The simple mosaic pattern of two principal species are located in that matrix. The simple mosaic pattern of two principal species seems to be controlled by change in micro-environmental pattern. Differences between the primary random group and clumped group among sites also suggest that competition exists for light or/and soil between primary clumped groups.

  • PDF

고혈압 환자에서 곡운침법의 혈압강하 효과 (Gogoon acupuncture for hypertension)

  • 한창현;송태원;신미숙;신선화;최선미
    • Korean Journal of Acupuncture
    • /
    • 제24권1호
    • /
    • pp.27-41
    • /
    • 2007
  • Objectives : The aim of this study was to investigate the antihypertensive effect of Korean Gogoon Acupuncture in hypertensive patients. Methods : We measured the blood pressure of 17 patients who were admitted in the Oriental Medical Clinic of Gogoon Institute from 14th April 2006 to 29th August 2006. Eligible participants had systolic blood pressure ${\geq}120$ mmHg or diastolic blood $pressure{\geq}80$ mmHg. Blood pressure and pulse rate measurements were after the patient had been in bed rest for at least 30 min. Six sessions of Gogoon Acupuncture treatment over three weeks were performed in the patients. Blood pressure and pulse rate were measured twice before and after each acupuncture treatment. Results : After 3 weeks, there were significant decreases in systolic blood pressure(p=0.0028), diastolic blood pressure (p=0.0111) and pulse rate (p=0.0150). The effects of Gogoon Acupuncture by measuring time on blood pressure were as follows : In a systolic blood pressure (p<.0001) and diastolic blood pressure (p=0.0028) was gradually deceased significantly from 1st to 6th but pulse rate was not significantly decreased. Conclusions : Controlled trials investigating the efficacy of Gogoon acupuncture for lowering blood pressure are warranted.

  • PDF

고압 전력기기에서의 $SF_6$ Gas 사용단계별 배출특성에 관한 연구 ($SF_6$ Emission Characteristics at High Voltage Equipments in use-phase Stage)

  • 박정주;조연행
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2199-2201
    • /
    • 2008
  • Sulfur hexafluoride($SF_6$) is a gaseous dielectric used in high voltage electrical equipment such as an insultor or arc quenching medium in the transmission and distribution of electricity. however, $SF_6$ is one of the greenhouse gases(GHG) with a global warming potential that is 23,900 times greater than that of carbon dioxide($CO_2$). for this reason, $SF_6$ emissions in electric equipment shall be controlled to reduce GHG and improve cost-effective use of $SF_6$ for economical benefits. Until recently there has not been any investigation on $SF_6$ emission characteristics and inventory in Korea. To understand emission characteristics during the use-phase, the scope of this study was limited to the following closed pressure system equipment from 10 substations in Korea. This study highlights (1) the investigation of sampling/analysis methodology for $SF_6$ emissions in high voltage equipment, (2) the estimation of $SF_6$ emissions in the use-phase, and (3) the comparison between the emission ratio and the mass-balance applied to inventory study. According to this study, the majority of emissions were related to electric equipment nameplates and the rest of the emissions were related to the handling of $SF_6$ during operations. from this result, emission ratios estimated from this study were similar; GIS was 14% and GCB was 13%, as maintenance process conditions were the same as manual process conditions for both equipment.

환경온도 -10℃에서 Clo값에 따른 인체 생리반응 및 주관적 감각 (Physiological Responses and Subjective Sensations by Clo Values at -10℃)

  • 김지연;송민규;김희은
    • 한국의류산업학회지
    • /
    • 제12권4호
    • /
    • pp.531-537
    • /
    • 2010
  • The purpose of this study was to review physiological responses and subjective sensations in the cold environment when the subjects wore ensemble with different clo values. Seven healthy male subjects participated in this experiment. This experiment was conducted in a climatic chamber with $-10^sC$ and 50%RH. Subjects wore five different kinds of ensemble[C1 (4.453 clo), C2 (3.452 clo), C3 (2.865 clo), C4 (2.387 clo), and C5 (2.280 clo)]. The experiment was composed of 20 min of rest period, 20min of treadmill exercise(6 km/h) period, 30 min of recovery period. We monitored skin temperature on 7 sites, clothing microclimate and subjective sensations. The clo value had positive correlations with mean skin temperature and clothing microclimate. The subjects feel more warm and humid as the clo value goes up. The subjects reported comfort when they wore C1 and C2 ensemble having over 3 clo value. However, they felt less comfortable during the exercise period since there was high humidity. Skin temperature on the extremities were more dramatically changed by the exercise rather than clo value. Thus it seems that in the cold environment, heat balance can mostly be controlled by the choice of clothing, and the clothes with high clo values can provide higher insulation. In conclusion, our findings suggest that it would be more effective to control clo value depending on the activity level for maintaining comfort level in the cold environment.

Immediate Effects of Myofascial Release Using Vibration Foam Rolling Methods on Hamstrings Range of Motion, Flexibility, Pressure Pain Thresholds and Dynamic Balance

  • Kim, Ho;Shin, Wonseob
    • 국제물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.2042-2051
    • /
    • 2020
  • Background: Many trials have been conducted the methods and types of intervention of form rollers, but no research has been done yet that mixes the methods and types of intervention. Objectives: To analyze the effects of myofascial release on the improvement of range of motion (ROM), flexibility, pain pressure threshold, and balance. Design: Randomized controlled trial. Methods: All subjects measured ROM, flexibility, pressure pain threshold, and dynamic balance by pre-test. After pre-test, subjects were randomized that static-vibration foam rolling group (n=12), dynamic-vibration foam rolling group (n=12), general foam rolling group (n=12). For the intervention, 3 sets of 90 seconds were applied to each group, and rest time was set to 60 seconds between sets. In the post-test and follow-up test after 10 minutes, all three groups were measured the ROM, flexibility, pressure pain threshold, and dynamic balance. Results: The results of comparing ROM, flexibility, pressure pain thresholds, dynamic balance ability appeared higher significant difference in the pre-post-10 minutes follow up test in comparison between time in the intragroup (P<.001). As a result of comparing the change of pre-post-10 minutes follow up, static vibration foam rolling showed higher significant difference compared to control groups (P<.001). Conclusion: Through this study, when foam rolling is applied within the same intervention time, static foam rolling can be expected to have a better effect than the existing dynamic foam rolling as well as vibration foam roller can expect better effect than general foam rolling.

완전 이식형 인공중이를 위한 베개형 비접촉 충전장치의 설계 (Design of pillow type contactless recharging device for totally implantable middle ear systems)

  • 임형규;김종민;김민규;윤영호;박일용;송병섭;조진호
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.78-84
    • /
    • 2005
  • A contactless recharging device for totally implantable middle ear systems has been designed as a pillow type that the user can recharge the implanted battery with taking a rest. The proposed device uses the electromagnetic coupling between the transmitting coil and the receiving coil. To supply sufficient power for the implanted circuits, each coil uses LC resonance and the implanted device uses voltage doubler. A power MOSFET is used for switching the DC voltage of LC parallel circuit and the switching frequency demands on a programmable frequency generator which is controlled by microcontroller. In order to improve the electromagnetic coupling efficiency at specific positions of coil which may vary with the displacement of head, the optimal location of receiving coil was studied, and the 5 transmitting coils in a pillow for recharging the implant module was designed. From such a recharging experiment, it was found that the proposed device could provide the sufficient operating voltage within the distance of 4 cm between pillow and the implanted device.

에어로빅복의 유니버설 디자인을 위한 동작 적합성 평가 (An Evaluation of Aerobic Exercise Wear Mobility as a Basic Criterion for Universal Design)

  • 손주희;최정화;강태진
    • 한국의류학회지
    • /
    • 제31권3호
    • /
    • pp.343-350
    • /
    • 2007
  • This study compared and studied the clothing mobility of two types of aerobic clothes - those made of currently popular stretch materials and those made of new stretch materials that were specially developed for this study. The focus of the comparison was on the range of joint movement during activity, and the physiological burden imposed on the body by the clothes. In total, 18 experiments were carried out under controlled conditions in an artificial climatic chamber with a temperature of $25{\pm}1^{\circ}C$, air humidity of $60{\pm}5^{\circ}C$ and negligible air movement. Each exercise program consisted of a 30-minute of aerobic workout and a 20-minute rest following the exercise. Measurements were taken to determine the following: physiological reactions (whole-body and local sweat rates), subjective sensations(of temperature, humidity, comfort, tightness, and clothing wetness), joint angle(measured with a goniometer), and so on. The results of the study us as follows: Material B excels in clothing mobility. Material C excels in sweat absorbency and drying speed. Material A was found to be the hottest material, while material C was found to be slightly hot through the analysis of the change in pre- and post-exercise bodyweight(= amount of sweat). Regarding the amount of evaporated sweat, material A>material C>material B. Material B produced the smallest amount of evaporated sweat. The wider the range of joint movement, the smaller the amount of sweat and the lower the average skin temperature.

Interaction between UN and CdCl2 in molten LiCl-KCl eutectic. I. Experiment at 773 K

  • Zhitkov, Alexander;Potapov, Alexei;Karimov, Kirill;Shishkin, Vladimir;Dedyukhin, Alexander;Zaykov, Yury
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.123-134
    • /
    • 2020
  • The interaction between UN and CdCl2 in the LiCl-KCl molten eutectic was studied at 773 K. The reaction was controlled by sampling the melt, as well as by analysis of the resulting precipitate. The process was shown to proceed according to several parallel reactions. The summary reaction was determined to have two stages: a fast one and a slow one. The 19-53% UN → UCl3 conversion was obtained for the molar ratio of CdCl2/UN = 1.22-14.9. The rest of UN converts into the precipitate of complex composition (UNCl + U2N3 + U4N7 + UN2). The increase in the CdCl2/UN molar ratio from 1.22 to 14.9 resulted in the decrease in duration of the first "fast" stage of the process from 18 h to 1 h.

Experiments on granular flow in a hexagonal silo: a design that minimizes dynamic stresses

  • Hernandez-Cordero, Juan;Zenit, R.;Geffroy, E.;Mena, B.;Huilgol, R.R.
    • Korea-Australia Rheology Journal
    • /
    • 제12권1호
    • /
    • pp.55-67
    • /
    • 2000
  • In this paper, an experimental study of the rheological behavior of granular flow in a new type of storage silo is presented. The main characteristic of the new design is a hexagonal shape chosen with the objective of minimizing the stresses applied to the stored grains, and to reduce grain damage during the filling and emptying processes. Measurements of stress distribution and flow patterns are shown for a variety of granular materials. Because of the design of the silo, the granular material adopts its natural rest angle at all times eliminating collisional stresses and impacts between grains. A homogeneous, low friction flow is naturally achieved which provides a controlled stress distribution throughout the silo during filling and emptying. Secondary dynamic stresses, which are responsible for wall failure in conventional silos of the vertical type, are completely eliminated. A comparison between the two geometries is presented with data obtained for these silos and a number of granular materials. The discharge pattern inhibits powder formation in the silo and the filling system virtually eliminates unwanted material packing. Finally, notwithstanding the rheological advantages of this new design, the hexagonal cells that constitute the silo have many other advantages, such as the possible use of solar energy to control the humidity inside them. The cell type design allows for versatile storage capabilities and the elevation above the ground provides unlimited transportation facilities during emptying.

  • PDF