• Title/Summary/Keyword: Controlled Pressure

Search Result 1,572, Processing Time 0.024 seconds

Influence of changing Combustor Pressure on Flame Stabilization and Emission Charncteristics (연소실 압력변동이 화염안정화와 배출특성에 미치는 영향)

  • Kim, Jong-Ryul;Choi, Gyung-Min;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2354-2359
    • /
    • 2007
  • Influence of changing combustor pressure on flame stabilization and emission index in the swirl-stabilized flame was investigated. The combustor pressure was controlled by suction fan at combustor exit. Pressure index ($P^{\ast}$=Pabs/Patm), where Pabs and Patm indicated the absolute pressure and atmosphere pressure, respectively, was controlled in the range of 0.7${\sim}$1.3 for each equivalence ratio conditions. The flammable limits of swirl flames were largely influenced by changing combustor pressure and they showed similar tendency with laminar flames. NOx emission index decreased with decreasing pressure index for overall equivalence ratio conditions. R.m.s. of pressure fluctuations is increased with decreasing combustor pressure. This flame fluctuation caused incomplete combustion, hence CO emission index increased. These oscillating flames were measured by simultaneous $CH^{\ast}$ chemiluminescence time-series visualization and pressure fluctuation measurement.

  • PDF

Rigid-Plastic Finite Element Analysis of Axi-Symmetric Hydroforming with Controlled Pressure (유체압력이 제어되는 축대칭 하이드로포밍에 대한 강소성 유한요소 해석)

  • 양동열;권혁주;정완진;노태성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.571-580
    • /
    • 1990
  • The study is concerned with the analysis of axisymmetric hydroforming with controlled pressure by the rigid-plastic finite element method. The finite element method is employed to obtain the detailed information including the distribution of stresses and strains and geometry changes. Experiments are carried out for hydroforming of cold-rolled steel sheets with the developed CNC hydroforming press which is pressure-controlled according to the fluid pressure vs.-stroke relationship given by the upper bound. Four types of punches are used for the experiments. The computed results are in good agreements with the experimental observation in geometric change and thickness variation. The present analysis permits the prediction of stresses, strains, geometric changes. The effects of Lankford value and workhardening exponent on thickness strains in hydroforming are also discussed. It is thus shown that the present method can be applied to the effective design of axisymmetric hydrooforming processes.

An Analysis for Turbulent Hybrid Bearings with Fluid Inertia and Swirl Injection Effects (유체의 관성력과 스월의 영향을 고려한 난류 하이브리드 베어링의 해석)

  • 이용복;김창호;최동훈
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.85-91
    • /
    • 1996
  • An analysis for turbulent hybrid beatings with fluid inertia and swirl injection effect was derived for studying static characteristics of swirl-controlled hybrid journal. The swirl-controlled hybrid journal beating is considered to have more freedom in stability control in high speed rotating machinery. Current analysis is compared with experimental results with 3-recess hydrostatic journal bearing. The analysis revealed that the fluid momentum exchange at orifice discharge could produce pressure rise inside the recess region which can control the shear flow induced by journal rotation. The analysis also shows that the swirl-controlled hybrid journal beating has a capability of controlling load carrying capacity and stability by manipulating supply pressure and injection angle.

Development of Numerically Controlled Cushion System for Use in Deep Drawing of Sheet Metals (박판의 덥 드로잉 성형을 위한 수치제어 쿠션 시스팀의 개발)

  • 이정우;최치수
    • Transactions of Materials Processing
    • /
    • v.10 no.2
    • /
    • pp.115-122
    • /
    • 2001
  • It is well known, for many years, that deep drawability can be improved by applying variable blank holding force. To apply variable blank holding force during cup drawing, we set up cushion pressure control system on the hydraulic press, and the pressure control system is often called NC(Numerically Controlled) cushion system. A cushion pressure control experiment was carried out using the NC cushion and it was shown that the proposed system produced good performance. The comparison of drawability of square cups with and without NC cushion showed that the drawability could be greatly improved when S-shaped pressure curve was applied. This paper includes design details of the NC cushion system and experimental analysis of drawability with NC cushion system.

  • PDF

A Development of the electronic controlled vaporizer for low flow anesthesia (저유량 마취를 위한 전자제어식 기화기 개발)

  • Oh, Yeong-Taek;Park, Jae-Hoon;Chang, In-Bae
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.107-113
    • /
    • 2009
  • For the environmental safety of the operating room and patient healthcare, the closed type rebreathing system is widely adopted. In order to reduce the anesthesia gas during surgery, the mixing ratio of anesthesia gas with breathing air should be precisely controlled. Generally, the breathing air passes through the vaporizer to mix the anesthesia gas, but there is a difficulty in controlling the mixing ratio precisely. In this paper, the stand-alone style vaporizer is designed and the operating characteristics are investigated. The vaporizer measures the temperature and pressure in the vaporizing chamber and chamber temperature is precisely controlled by proportional controlled heater. Exact quantity of anesthesia media is feeded by PID controlled peristaltic pump and vaporized gas is mixed with breathing air flow by PWM controlled solenoid valve. The experimental result shows that the vaporizer has an excellent command following performances that it can be applied to the low flow anesthesia system.

  • PDF

The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation (Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향)

  • Choi, Won-Jun;Jung, Sung-Han;Lee, Jeong-A;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1022-1030
    • /
    • 1998
  • Background : In volume-controlled ventilation, the use of inspiratory pause increases the inspiratory time and thus increases mean airway pressure and improves ventilation. But under the same I : E ratio, the effects of inspiratory pause on mean airway pressure and gas exchange are not certain. Moreover, the effects may be different according to the resistance of respiratory system. So we studied the effects of inspiratory pause on airway pressure and gas exchange under the same I : E ratio in volume-controlled ventilation. Methods: Airway pressure and arterial blood gases were evaluated in 12 patients under volume-controlled mechanical ventilation with and without inspiratory pause time 5%. The I : E ratio of 1 : 3, $FiO_2$, tidal volume, respiratory rate, and PEEP were kept constant. Results: $PaCO_2$ with inspiratory pause was lower than without inspiratory pause ($38.6{\pm}7.4$ mmHg vs. $41.0{\pm}7.7$ mmHg. p<0.01). P(A-a)$O_2$ was not different between ventilation with and without inspiratory pause $185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, p=0.766). Mean airway pressure with inspiratory pause was higher than without inspiratory pause ($9.7{\pm}4.0\;cmH_2O$ vs. $8.8{\pm}4.0\;cmH_2O$, p<0.01). The resistance of respiratory system inversely correlated with the pressure difference between plateau pressure with pause and peak inspiratory pressure without pause (r=-0.777, p<0.l), but positively correlated with the pressure difference between peak inspiratory pressure with pause and peak inspiratory pressure without pause (r=0.811, p<0.01). Thus the amount of increase in mean airway pressure with pause positively correlated with the resistance of respiratory system (r=0.681, p<0.05). However, the change of mean airway pressure did not correlated with the change of $PaCO_2$. Conclusion: In volume-controlled ventilation under the same I : E ratio of 1 : 3, inspiratory pause time of 5% increases mean airway pressure and improves ventilation. Although the higher resistance of respiratory system, the more increased mean airway pressure, the increase in mean airway pressure did not correlated with the change in $PaCO_2$.

  • PDF

An Experimental Study on the Measuring Lateral Formwork Pressure Controlled by Super-Workable Fresh Concrete (고유동 콘크리트의 거푸집 측압 측정에 관한 실험적 연구)

  • 이준구;박광수;김한중;배수호
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.142-145
    • /
    • 1998
  • The purpose of this study is to estimate lateral formwork pressure controlled by super-workable fresh concrete using prototype structrues such as, tall wall, retaining wall, and beam quantitativly. As a result of this experiment, a function which can be used to design a formwork system and to predict formwork pressure curve is formulated.

  • PDF

Development of Inverter Controlled Air Pressure Type Water-Supply and Determination of Optimal Operation Pressure (무접점 공기압력식 급수시스템 개발 및 최적운전점 결정)

  • Kim, Jung-Hoon;Kim, Hak-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.181-183
    • /
    • 1994
  • This paper presented the developments and operations of control system for Inverter-controlled air pressure type water-supply systems. The developed controller that enables regular speed and variable speed. In addition, an air supplement control system was developed to establish a utility model of water supply facility system as well as a method to optimize its operation.

  • PDF

Disposable Microfluidic Infusion Pump using Elastomeric Blister Actuator (탄성 블리스터 액츄에이터를 이용한 일회용 미세유체 주입펌프)

  • Jang, Woong Ki;Kim, Hyung Jin;Kim, Byeong Hee;Seo, Young Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.235-240
    • /
    • 2013
  • This paper presents a disposable microfluidic infusion pump using the restoring force of elastomeric membrane of Polydimethylsiloxane. Microfluidic infusion pump consists of hydraulic resistance control part, elastomeric blister actuator part, drug inlet and outlet. Expanded elastomeric blister actuator continuously pushes liquid in the chamber to outlet. At same time, microchannel diameter near the outlet was controlled by thin elastomeric membrane in hydraulic resistance control part. Eventually flow rate of infused liquid is controlled by air pressure. In experimental study, the amount of the filled liquid in the blister is precisely controlled by the height of the blister. Flow rate of infused liquid could be controlled, that is, controlled release of the drug over time was possible by adjusting hydraulic resistance and restoring pressure with the blister actuator.

The Development of Check equipment Maintaining air pressure constantly for Automobile (자동차용 공기압을 일정하게 유지하는 검사 장치의 개발)

  • Kim, Seok-Hyun
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2009.05a
    • /
    • pp.184-189
    • /
    • 2009
  • The Measurement system of auto parts are currently precious ones in the case of most of them. In this paper We tried to implement low_cost equipment. There are many auto parts. Among them CCP(Canister Controlled Purge Solenoid) which have difficulties in the control of air fluid currently have been main object. According to the use of air amount. Required time to maintain vacuum air pressure constantly need three or four minutes but the aim of this development try to achieve keeping vacuum pressure within less shorter time, Under the constant air pressure, We try to develop control check system of auto parts CCP(Canister Controlled Purge Solenoid).

  • PDF