• Title/Summary/Keyword: Control room

Search Result 1,974, Processing Time 0.029 seconds

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

Studies of the Physiological Impediments on the Silkworm(Bombyx mori L.) due to Anthracite Gas -Regarding with Carbon Monoxide and Sulphur Dioxide- (무연탄가스에 의한 가잠의 발육과 생리작용에 미치는 영향에 관한 연구-산화탄소와 무수아황산가스를 중심으로-)

  • 윤종관
    • Journal of Sericultural and Entomological Science
    • /
    • v.10
    • /
    • pp.1-25
    • /
    • 1969
  • Since widely use of anthracite for the radiating purpose in a rearing room in Korea, the weakness of silkworm, poor uniformity of the worm growth, the increase of missing worm ratio, unusual cocoon assorting ratio, and the decrease of cocoon layer ratio have been realized by the author, therefore, he has started out to search the mechanism of these evil influences regarding with various gas densities and terms of the gas treatment which will be supposed to be a warning for temperature control during the silkworm reading work. Among the anthracite gas components, CO or SO$_2$ influence and their complexed harm effect were investigated through the use of anthracite gas, CO and SO$_2$ gas. Meantime, each treatment was applied, separately, during the worm egg stage, young instar, adult instar and whole instar, because the harm intensity for any improperable rearing condition is flexible by the growing stages. Meantime, the gas density and term variation were applied for the above each treatment such as in case of anthracite and CO gas, the following treat methods were used. 1) 0.06% for 30 mins. 2) 0.06% for 1 hour. 3) 0.1% for 1 hour. 4) 0.15% for 1 hour. on the other hand, SO$_2$ gas was used as 1) 120ppm for 30 mins. 2) 200ppm for 30 mins. 3) 400ppm for 30 mins. The measurement of gas density was proceeded by using CO tester (Carbon Monoxide Indicator) and SO$_2$ tester (Indicator Sampler Cgf) which could keep any specific density before each treatment.

  • PDF

Effect of Humidified High Flow CO2 Gas Insufflation on the Coronary Endothelium (가습화한 고유량의 이산화탄소가스 통기가 관상동맥 내피세포층에 미치는 영향)

  • 최재성;김준성;서정욱;김기봉
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.131-138
    • /
    • 2004
  • High-flow gas insufflation to get a bloodless field during off-pump coronary artery bypass may have adverse effects on the coronary endothelium. This study was designed (1) to elucidate the effect of carbon dioxide gas insufflations on the coronary endothelium at different flow rates and (2) to assess the protective effect of humidifcation against the coronary endothelial damage. Material and Method: In nine pigs, the left anterior descending coronary artery (LAD) was exposed after a median sternotomy. The LAD was divided into 4 segments and a coronary arteriotomy was made in each LAD segment in the beating heart. The far distal arteriotomy was exposed to room air for 10 minutes and was harvested as a control. Non-humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group I), humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group II), and humidified carbon dioxide gas at a continuous flow rate of 10 L/min (Group III) were insufflated for 10 minutes on each coronary arteriotomy site, respectively. After harvesting the coronary segments, hematoxylin-eosin staining, elastic fiber staining, and immunostaining with a CD34 monoclonal antibody were performed to evaluate the depth of endothelial damage and to count the residual endothelial cells, Result: In all three groups (Group I, II, and III), internal elastic laminae were preserved, however, the endothelial layers were significantly damaged by carbon dioxide gas insufflation. The mean percentages of remaining endothelial cells were 20,9$\pm$16.7%, 39.3$\pm$19.6%, and 6.8$\pm$5.3%, in groups I, II, and III, respectively. The percentages of remaining cells were significantly higher in group II than in groups I and III (p=0.008). The percentages of remaining cells were significantly higher in group I than in group III (p=0.008). Conclusions: The harmful effect of carbon dioxide gas insufflation on the coronary endothelium was dependent on the flow rate. The addition of humidification did not protect the coronary endothelium from denudation injury caused by high flow carbon dioxide gas insufflations.

Effects of Gamma Irradiation and Ethylene Oxide Fumigation for the Quality Preservation of Spices and Dry Vegetables (건조향신 조미식품의 품질보존을 위한 효과적인 살균방법에 관한 비교연구)

  • 신광순;마점술;조종후
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.2
    • /
    • pp.119-132
    • /
    • 1989
  • Gamma irradiation as a new physical treatment was applied to comparative investigates with a conventional ethylene oxide fumigant on the microbiological and physicochemical qualities of selected spices and dry vegetables such as powdered red pepper, black pepper, welsh onion, onion, garlic, carrot, korean cabbage and instant ramyon soup. The microorganisms contaminated in the sample, including total viable count, thermophilic bacteria, aerobic spore and fungi counts between the $10^4\;to\;10^6/g$ range. Coliforms were found only in black pepper and welsh onion powder as the $10^2\;to\;10^3/g$ level. A radiation dose of 7 to 10 KGy were sterilized completely to the contaminated microorganisms, while ehthylene oxide (E.O.) fumigation reduced of them to the $10^3/g$ level. An optimum dose of irradiation was less detrimental than E.O. fumigation to the physicochemical properties of the sample. Sensory evaluation after three months of storage at room temperatures showed that the overall acceptability of irradiated sample was higher than that of the non treated control as well as E.O. fumigated samples. Comparison gamma irradiation with E.O. gas treatment showed that E.O. treatment was less effective than radiation in cotrolling microbial contamination of spices and vegetables.

  • PDF

The effects GeongshinhaeGihwan 1(GGT1) has on the hGHTg (human growth hormone transgenic) obese male rats' blood-antiobestic index (형질전환 비만모델 수컷 hGHTg rats에서 경신해지환(輕身解脂丸)이 혈중 항비만지표에 미치는 영향)

  • Jung, Yang-Sam;Tsung, Pei-Chin;Choi, Seung-Bae;Kim, Gyeong -Cheol;Shin, Soon-Shik
    • Herbal Formula Science
    • /
    • v.13 no.2
    • /
    • pp.1-16
    • /
    • 2005
  • Objectives: To find out the effects GGTl, an antiobestic drug widely used in clinics, has on the blood-antiobestic index and the toxicity index using the data from the hGHTg obese male rats. We looked closely into both of the two indices because GGTl antiobestic effect can happen not only by pharmacological action, but also by its toxicity. Also, we verified the difference in effect between GGTl and reductil (sibutramine), which has been approved by the FDA of the United States. Methods: After performing the experiments for 8 weeks on the hGHTg obese male rats divided into three groups: the control group, the GGTl group, and the reductil (RD) group, we anesthetized the rats with Diethyl ether and took a 3ml blood sample from the heart. Then, after coagulating the blood in room temperature by using the plasma separator, we centrifuged it for 25 minutes in 3,000rpm using the high-speed refrigerated centrifuge. We kept the separated plasma in a deep freezer at $-80^{\circ}C$, and repeatedly measured the antiobestic index and the toxicity index twice using the hematology biochemistry analyzer. Also, in order to judge the indirect toxicity index, we separated liver from kidney and observed them. Results: When we looked at the results of the analysis of covariance on the measuring elements related to the antiobestic index (TC, HDL, LDL, TG, and GLU), there was no significant difference among the groups in all measuring elements. Also, the results of the analysis of covariance on the two roups (RD group and GGTl group) showed that the p-values had no significant difference under the level of significance 0.05. When we looked at the result of the analysis of covariance on the measuring elements related to the toxicity index (GOT, GPT, GGT, CREA, UA, ALB, and TP), we could see that the p-values in GPT, ALB, and TP have a significant difference among the groups. Also, the results of the analysis of covariance about the measuring elements related to the toxicity index on both groups, RD group and GGTl group, showed no significant difference in the p-values of all of the measuring elements in the two groups, RD and GGTl group. Conclusions: In conclusion, through this experiment, the safety of GGTl has been approved, and although the verification on its medical effect has not been clearly approved, when we consider the fact that it belongs to the same group as reductil, an antiobestic drug approved by the FDA of the United States, we could indirectly verify that GGTl has an antiobestic effect. We believe that when doing a sample design for a future experiment, it needs to be performed on a greater sample size based on the power analysis that needs to be performed primarily in experiments, and a more accurate verification is needed through more systematic experiment plans.

  • PDF

Characteristic Changes of Swine Manure by Air Suction Composting System (돈분 퇴비화 시 공기 흡입 시스템에 따른 퇴비화 특성 변화)

  • Lee, Dong-jun;Kim, Jung Kon;Jeong, Kwang-Hwa;Cho, Won-Mo;Ravindran, B.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.63-74
    • /
    • 2016
  • The objective of this study was to investigate the variations of physico-chemical properties during the swine manure composting, sawdust as the bulking agent was composted at different points (Top layer, Side of middle layer, Bottom layer). Air suction system with constant bottom aeration in bench scale reactors (30 L). The highest temperature was reached in the range of $58^{\circ}C$ to $62^{\circ}C$ on $3^{rd}$ day and this thermophilic phase (> $50^{\circ}C$) was continued for 3 days in all the treatment mixtures. However, the temperature was gradually decreased to room temperature at the end of 60 day composting process. Except control, the discharged ammonia ($NH_3$) was a maximum in the treatment order of Top layer>Bottom layer>Side of middle layer as 500 ppm, 162 ppm and 120 ppm, respectively, on the $4^{th}$ day and showing that Top layer point Air suction produce much more ammonia content than the other point. During the composting process, the total Kjeldahl nitrogen (TKN) was gradually increased due to the mass loss in the composting mixtures. At the same time, C/N ratio was decreased to Top layer, 13; Side of middle layer, 12 and Bottom layer, 13 at Air suction points. The significant reduction of C/N ratio in all different air suction system when manure was matured. The $NH_4-N$ to $NO_3-N$ ratio was recorded as 10.52 at the initial stage of the compost mixtures and reduced to 0.97 (Top layer), 0.70 (Side of middle layer), 3.2 (Bottom layer) because of manure decomposition. The overall results revealed that Top layer and Side of middle layer Air suction is a suitable option when compared other point for high quality composts.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy (재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용)

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.

  • PDF

Immunoelectron Microscopic Study on the Paneth Cell of Rabbit after the Common Bile Duct Ligation (총담관결찰후 집토끼 Paneth세포의 변화에 대한 면역전자현미경적 연구)

  • Park, Kyung-Ho;Cho, Hwee-Dong;Yang, Nam-Gil;Ahn, E-Tay;Ko, Jeong-Sik;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.24 no.2
    • /
    • pp.78-92
    • /
    • 1994
  • Lysozyme has been reported to be present in the secretory granules of the Paneth cell, and lysozyme immunoreactivity has been detected by immunogold method in Paneth cells of the intestine of human, mouse and rat. The present study was aimed at clarifying the intracellular distribution and changes of the lysozyme immunoreactivity in rabbit Paneth cell after common bile duct ligation of rabbit, using the electron microscope immunogold technique. Healthy adult rabbits weighing about 2kg body weight were divided into normal and bile duct ligated groups. Common bile duct ligation was performed aseptically under ether anesthesia. Experimental animals were sacrificed on the 1st, the 3rd, the 5th, the 7th and the 14th day after the operation. Mucosal specimens from the intestinal gland of ileum were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde, followed by 1% osmium tetroxide, embedded in araldite mixture, cut with LKB-V ultratome. Ultrathin sections were placed on parlodion coated nickel grids (200mesh). The section-bearing grids were floated upside down on the added substance in a moist chamber at room temperature except for the primary antibody step, which was at $4^{\circ}C$. Sections were etched with a saturated solution of sodium m-periodate for 60min. After etching, sections were pretreated with 0.02M tris buffered saline (TBS), pH 8.4, with 1% bovine serum albumin (BSA, Sigma) for 60min, then treated polyclonal rabbit anti-human lysozyme (Dakipatts) diluted 1 : 50 in TBS with 0.1% BSA for 20hr. Subsequently, grids were incubated 60min in biotinylated goat anti rabbit IgG (Amersham) diluted 1 : 100 in TBS with 0.1% BSA. After this, sections were incubated 60min on streptavidin gold G10 (Amersham) diluted 1 : 50 in TBS with 0.1% BSA. After each step, the grids were briefly rinsed with TBS with 0.1% BSA. After the strepavidin gold step, the sections were jet washed with distilled water. Counterstain of the sections performed by uranyl acetate and lead citrate, and observed with JEM 100 CX II electron microscope. Observed results were as follow; 1. Secretory granules of mouse Paneth cells have a lysozyme immunoreactivity and also eosinophil leucocyte of rabbit applied for the positive-control stain, are well labeld with gold particles. 2. Normal rabbit Paneth cells have a lysozyme immunoreactivity restricted on the secretory granules. 3. Amount lysosomes containing myelin figures in the Paneth cells were significantly increased from 5th day after the common bile duct ligation. 4. Immunoreactivity of Paneth cell secretory granules were more activated on the 3rd day after the common bile duct ligation as compared with those of the normal animal. But the lysozyme immunoreactivity were decreased from the 5th day after the common bile duct ligation. 5. Considering the above finding, lysozyme contained Paneth cell are affected following of common bile duct ligation, whereas lysosomes containing myelin-figure do not exhibit any immunoreactive relationship with those of secretory granules.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Simultaneous HPLC Determination of Marker Compounds for the Standardization of Hedyotis diffusa (백운풀의 지표성분 설정 및 품질표준화를 위한 정량 분석법)

  • Bang, Han-Yeol;Yang, Eun-Ju;Kim, Jeong-Ah;Song, Kyung-Sik
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1025-1031
    • /
    • 2013
  • From a 95% ethanolic extract of H. diffusa, four marker compounds (HD1~HD4) were isolated, which were relatively unique and exist in comparably high contents. The structures of marker compounds were identified as digitolutein (1), 2-hydroxy-3-methylanthraquinone (2), (E/Z)-6-O-p-coumaroyl scandoside methyl ester (4:1 mixture) (3), and (E/Z)-6-O-p-methoxycinnamoyl scandoside methyl ester (4:1 mixture) (4), respectively, on the basis of $^{13}C$ and $^1H$-NMR analyses. The calibration curves of marker compounds showed high linearity, as their correlation coefficient ($R^2$) were in the range of 0.9991~0.9999. In addition, the limit of detection (LOD) and the limit of quantification (LOQ) were $0.03{\sim}0.07{\mu}g/ml$ and $0.099{\sim}0.231{\mu}g/ml$, respectively. The intra-day/inter-day precision and accuracy were 0.23~2.00%/0.25~1.16% and 94.60~108.44%/94.73-110.23%, respectively. The optimal HPLC conditions for the simultaneous quantification of HD1~HD4 were as follows: stationary phase; Merck Chromolith RP-18e ($100{\times}4.6mm$, $5{\mu}m$), column temp.; room temperature, UV detection at 280 nm, flow rate; 2.0 ml/min, injection volume; $10{\mu}l$, mobile phase; start with the mixture of 80% solvent A ($H_2O$ containing 0.5% acetic acid) and 20% solvent B (methanol containing 0.5% acetic acid) and gradually decrease solvent A to 40% in 9 min., then retain this condition to 18 min. Under the HPLC condition, the four marker compounds 1~4 were successfully separated without any interference of other constituents. The results obtained in this study are expected to be helpful for the development of nutraceutics and natural medicines and for the quality control of this plant.