• Title/Summary/Keyword: Control module

Search Result 2,649, Processing Time 0.03 seconds

Depression and Related Risk Factors in the Elderly with a Focused on Health Habits, Mental Health, Chronic Diseases, and Nutrient Intake Status: Data from the 2014 Korea National Health and Nutrition Examination Survey (우리나라 노인의 우울증과 관련 요인 - 생활습관, 정신건강, 만성질환 및 영양상태 중심으로 - : 2014 국민건강영양조사 자료)

  • Lee, Hye-Sang
    • Journal of the Korean Dietetic Association
    • /
    • v.24 no.2
    • /
    • pp.169-180
    • /
    • 2018
  • Depression is a major health problem that can lead to mortality. This study was conducted to assess the risk factors associated with depression in a group aged over 65 years by analyzing nationally representative Korean survey data. A total of 1,209 subjects were analyzed among the participants of the 2014 Korean National Health and Nutrition Examination Survey. Statistical methods for a complex sample were applied by using SPSS program(windows ver. 24.0). Depression assessments were carried out by using the 9-item depression module of the Patient Health Questionnaire-9 (PHQ-9). Depression ($PHQ-9{\geq}5$) was more frequently found in females (33.2%) compared to males (16.1%). However, there was no evidence suggesting that characteristics such as residence area, income level and age, except for educational level, were related with depression. The results of the logistic regression analysis showed that i) health habits such as smoking (OR: 2.26) and lack of aerobic physical activity (OR: 1.62), ii) mental health status such as bad self-rating of health status (OR: 4.30), more stress (OR: 8.31), and bad health-related quality of life (by EQ_5D, OR: 3.41), iii) chronic diseases such as obesity (OR: 0.66), hypercholesterolemia (OR: 1.57), anemia (OR: 1.91), and iv) low intake of energy (OR: 1.84) and calcium (OR: 1.71) were significantly associated with depression. This study suggests that certain characteristics of health habits, mental health status, chronic diseases and nutrient intake may be associated with depression. Prospective research on long-term control is needed to establish causal connections among those factors with depression.

Evaluation and Development of e-PBL for Cultivating Consciousness of Information and Communication Ethics (정보통신윤리의식 함양을 위한 e-PBL 개발 및 평가)

  • Lee, Jun-Hee;Yoo, Kwan-Hee
    • Journal of The Korean Association of Information Education
    • /
    • v.14 no.3
    • /
    • pp.437-447
    • /
    • 2010
  • The purpose of this thesis was to design and develop an effective e-PBL(Problem-Based Learning) for cultivating consciousness of information and communication ethics. The proposed e-PBL is based on PBL which is one of the constructivism teaching-learning theories. Online learning and face-to-face classes were systematically combined for achieving the teaching-learning goals. And the main module for online learning run on Moodle, an open source learning management system. To examine educational effectiveness of the proposed e-PBL, an experimental study was conducted through the education content and method to the subject of two class in the second-grade of university located in OO city. For experiment 60 students(treatment group=30, control group=30) are participated. And they were randomly assigned to one of ten subgroups, comprising of six students, respectively. The results of this study showed that the education using proposed e-PBL is more effective in cultivating consciousness of information and communication ethics and learners responded positively than the education using traditional face-to-face PBL learning method.

  • PDF

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

Design of Readout Circuit with Dual Slope Correction for photo sensor of LTPS TFT-LCD (LTPS TFT LCD 패널의 광 센서를 위한 dual slope 보정 회로)

  • Woo, Doo-Hyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.31-38
    • /
    • 2009
  • To improve the image quality and lower the power consumption of the mobile applications, it is the one of the best candidate to control the backlight unit of the LCD module with ambient light. Ambient light sensor and readout circuit were integrated in LCD panel for the mobile applications, and we designed them with LTPS TFT. We proposed noble start-up correction in order to correct the variation of the photo sensors in each panel. We used time-to-digital method for converting photo current to digital data. To effectively merge time-to-digital method with start-up correction, we proposed noble dual slope correction method. The entire readout circuit was designed and estimated with LTPS TFT process. The readout circuit has very simple and stable structure and timing, so it is suitable for LTPS TFT process. The readout circuit can correct the variation of the photo sensors without an additional equipment, and it outputs the 4-levels digital data per decade for input luminance that has a dynamic range of 60dB. The readout rate is 100 times/sec, and the linearity error for digital conversion is less than 18%.

Transmission System of TDM signal based on E-PON (E-PON 기반 TDM 신호 전송 시스템)

  • Kwon, Jeong-Gook;Jin, Geol;Park, Chun-Kwan;Song, Han-Young;Jeon, Byung-Chun;Lee, Sang-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.12
    • /
    • pp.63-72
    • /
    • 2007
  • This paper addresses the system development that can transfer data and TDM signals simultaneously by adding TDM pseudowires functions to E-PON system. E-PON technology is one of many technologies which can realize FTTH, has raised as next generation access network solution having both low-cost Ethernet technology and optical infrastructure. TDM pseudowires service is the new voice/data conversion technology which can transfer the existing TDM circuit switched voice and data over packet switching network. In this paper, this system can provide both data and TDM service without deteriorating QoS by adding TDM pseudowires service module to E-PON, and then implementing QoS control function. Therefore, the competitive system which can transfer both data and TDM signal, can be installed.

A Study on Evaluation of Power Management IC (전원모듈 PMIC 특성평가에 관한 연구)

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.260-264
    • /
    • 2016
  • The MAX77846, which is compatible with MAX77826, is a sub-power management IC (PMIC) for the latest Wearable Watch and 3G/4G smart phones. The MAX77846 contains N-MOSFET (N channel Metal-Oxide Semiconductor Field-Effect Transistor), a high-efficiency regulator, and comparator, etc to power up peripherals. The MAX77846 also provides power on/off control logic for complete flexibility and an $I^2C$ (Inter Integrated Circuit) serial interface to program individual regulator output voltages. In this paper, the simplified power macro-model based on MAX77846 is designed to verify the performance of the battery voltage in terms of current and time, and simulated by using of the LTspice. In addition, it is verified how much time can the charged battery capacity for Samsung Galaxy Gear 2 be used to operate a specified function after measuring the currents flowing to carry out the main functions in real time, which will be applicable to design parameters for the advanced power module

A Study on Dynamic Map Data Provision System for Automated Vehicle (자율주행을 위한 동적지도정보 제공에 관한 연구)

  • Yang, Inchul;Jeon, Woo Hoon;Lee, Hyang Mi
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.6
    • /
    • pp.208-218
    • /
    • 2017
  • This study aims to develop the Vehicle Local Dynamic Map (V-LDM) and demonstrate its performance for providing dynamic map data efficiently to the vehicle control module. Firstly, the concept of the in-vehicle LDM has been established and then the system has been carefully designed according to the international standards. The high-precision digital map embedded in LDM has been designed to incorporate the lane-level information of road network, and the Dynamic Map protocol (DM protocol) which is a message protocol including the road data with dynamic traffic event data has been defined. The performance test of the proposed system has been conducted in the uninterrupted road section of Kyungbu expressway, showing that both of the data size and the elapsed time to finish the process are almost linearly proportional to the length of target road. Finally, it is recommended that the length of target road for DM protocol be less than 250m.

The Analysis of the LCL Set-up Parameters for Satellite Power Distribution (위성전원분배를 위한 LCL 동작 파라미터 설정분석)

  • Lim, Seong-Bin;Jeon, Hyun-Jin;Kim, Kyung-Soo;Kim, Tae-Youn
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2011
  • In this paper, the characteristics of LCL set-up parameters for the satellite load distribution are analyzed under the electrical system environment, implemented the LCL circuits and evaluated the performance and its behaviour. Recently, it is implemented the load distribution circuit by latching current limiter(LCL) rather than conventional fuse and relay for the protection of the satellite power system from a fault load. The LCL circuit is composed of the electrical components, not mechanical parts with the fuse and relay. When detected the over current on a fault load, it is activated to maintain the trip-off level for set-up time and then cut-off the load power by the active control. It is more flexible and provided a chance to reuse of the load in case of temporarily event, but the fuse and relay can't be used again after activating due to the physical disconnection. However, for implementation of LCL circuit, it should be carefully considered the behavior of the LCL circuit under the worst electrical system environment and applied it to define the set-up parameters related with over-current inhibition.

Development of PV-Power-Hardware-In-Loop Simulator with Realtime to Improve the Performance of the Distributed PV Inverter (분산전원형 PV 인버터 성능 개선을 위한 실시간 처리기반의 PV-Power-Hardware-In-Loop 시뮬레이터 개발)

  • Kim, Dae-Jin;Kim, Byungki;Ryu, Kung-Sang;Lee, Gwang-Se;Jang, Moon-Seok;Ko, Hee-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.47-59
    • /
    • 2017
  • As the global warming threats to humanity, renewable energy is considered the key solution to overcome the climate change. In this circumstance, distributed PV systems are being expanded significantly its market share in the renewable energy industry. The performance of inverter is the most important component at PV system and numerous researches are focusing on it. In order to improve the inverter, PV simulator is an essential device to experiment under various load and conditions. This paper proposes the PV Power-Hardware-In-Loop simulator (PHILS) with real-time processing converted electrical and mathematical models to improve computation speed. Single-diode PV model is used in MATLAB/SIMULINK for the PV PHILS to boosting computation speed and dynamic model accuracy. In addition, control algorithms for sub-components such as DC amplifier, measurement device and several interface functions are implemented in the model. The proposed PV PHILS is validated by means of experiments with commercial PV module parameters.

A Study on Analysis for Energy Demand of the Heating, Cooling and Lighting in Office Building with Transparent Thin-film a-Si BIPV Window (투광형 박막 BIPV 창호 적용에 따른 냉난방 및 조명 부하 저감에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Park, Jang-Woo;Kim, Bit-Na
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2013
  • The purpose of this study was to analyze the annual energy demand including heating, cooling and lighting according to kind of windows with transparent thin-film a-Si Building Integrated Photovoltaic(a-Si BIPV) for office building. The analysis results of the annual energy demand indicated that the a-si BIPV window was reduced by 8.4% than the clear gazing window. The base model A was combinate with a-Si BIPV window area of 67% and clear window area of 33% among the total exterior area. The model B is to be applied with low-e clear glass instead of clear glass of the base model A. The model B was reduced to annual energy demand of 1% more than the model A. Therefore, By using a-si BIPV solar module, the cooling energy demand can be reduced by 53%(3.4MWh) and the heating energy demand can be increase by 58%(2.4MWh) than clear glazing window in office building. Also, Model C applied to the high efficient lighting device to the model B was reduced to annual energy demand of 14.4% more than the Model D applied to the high efficient lighting device to the model A. The Model E applied with daylight dimming control system to the Model C was reduced to annual energy demand of 5.9% more than Model C.