The Study on Acute and Subacute Toxicity and Sarcoma-180 Anti-cancer Effects of Vermilionum (영사(靈砂)의 급성(急性).아급성(亞急性) 독성(毒性) 및 Sarcoma-180 항암효과(抗癌效果)에 관(關)한 문헌적(文獻的) 연구(硏究))

  • Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.6 no.3
    • /
    • pp.39-47
    • /
    • 2003
  • Background & Methods : In order to measure the acute and subacute toxicity of Vermilionum and it's anti-cancer effects, Sarcoma-180 abdominal cancer cells were injected intravenously. The following results were obtained after measuring the survival rate, toxicity of the NK cells, and IL- 2 productivity. Results : 1. It was impossible to measure $LD_{50}$ value in the acute toxicity test and no toxic effects were witnessed in the clinical observation. 2. No significant differences were shown in the weight changes between the experiment groups and the control group in the acute toxicity test. 3. No peculiar toxic effects were shown in the subacute toxicity test and the weight changes were insignificant between the experiment groups and the control group. 4. In measuring the survival rate after inducing abdominal cancer by Sarcoma-180, the experiment groups showed increased of 9.52% compared to the control group. 5. In measuring the activity of NK cells, no significant changes were shown between the experiment groups and the control group. 6. In measuring the productivity of IL-2, significant reduction was shown in the experiment groups compared to the normal group, but no significance was witnessed compared to the control group.

A Study on an Automatic FES Control System for Paraplegic Walking Against Muscle Fatigue (근육피로도를 고려한 하반신 마비환자의 보행 자동제어 FES 시스템에 관한 연구)

  • Min, Byoung-Gwan;Kim, Jong-Weon;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.167-174
    • /
    • 1994
  • In this paper, a DSP and microcomputer-based EMG controlled functional electrical stimulation (FES) system, for restoring walking of paraplegics at the patients' own command, is presented. The above-lesion EMG is a time-varying nonstationary signal and its autoregressive (AR) parameters are identified by the nonstationary identification algorithm using a DSP chip. The identified AR parameters are used for the cloassification of the function and the control of the movement. The below-lesion response-EMG signal is used as a measure of muscle fatigue. This FES system is designed to measure muscle fatigue and control the stimulation intensity according to the amplitude of the response-EMG signal. While the automatic electrical intensity control is obtained by identifying the movement, the proposed FES system is suitable for the automatic control of paraplegic walking.

  • PDF

Economic Valuation of Official Management for Invasive Insects and Diseases in Fruits (과실 병해충에 대한 공적방제조치의 가치분석)

  • Kwon, Daeyoung;Son, Minsu;Kim, Brian H.S.
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.4
    • /
    • pp.67-76
    • /
    • 2014
  • The objective of this study is to estimate the economic value of official management and control for invasive insects and diseases in fruits. The direct and indirect effect of this control measure can be the changes in price of fruits and related goods, changes in export volume of domestic fruits, changes in total volume of fruit production, and reduce the risk in food safety. The contingent valuation method with the single-bounded dichotomous choice is employed to estimate each household's willingness-to-pay (WTP) to maintain official management and control measures. The total number of sample consists 2,050 respondents between the ages of 19-60 years, and the survey is conducted using Web-based survey. The estimated results for mean WTP is 5,443won per month per household. Therefore, the total economic value of official management and control on fruit in Korea is estimated to be approximately 94.4 billion won per month.

Quantitative Measure of Speaker Specific Information in Human Voice: From the Perspective of Information Theoretic Approach (정보이론 관점에서 음성 신호의 화자 특징 정보를 정량적으로 측정하는 방법에 관한 연구)

  • Kim Samuel;Seo Jung Tae;Kang Hong Goo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1E
    • /
    • pp.16-20
    • /
    • 2005
  • A novel scheme to measure the speaker information in speech signal is proposed. We develope the theory of quantitative measurement of the speaker characteristics in the information theoretic point of view, and connect it to the classification error rate. Homomorphic analysis based features, such as mel frequency cepstral coefficient (MFCC), linear prediction cepstral coefficient (LPCC), and linear frequency cepstral coefficient (LFCC) are studied to measure speaker specific information contained in those feature sets by computing mutual information. Theories and experimental results provide us quantitative measure of speaker information in speech signal.

Shape Adaptive Searching Region to Find Focused Image Points in 3D Shape Reconstruction (3차원 형체복원에 있어서 측정면에 적응적인 초점화소 탐색영역 결정기법)

  • 김현태;한문용;홍민철;차형태;한헌수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.77-77
    • /
    • 2000
  • The shape of small or curved object is usually reconstructed using a single camera by moving its lens position to find a sequence of the focused images. Most conventional methods have used a window with fixed shape to test the focus measure, which resulted in a deterioration of accuracy. To solve this problem, this paper proposes a new approach of using a shape adaptive window. It estimates the shape of the object at every step and applies the same shape of window to calculate the focus measure. Focus measure is based on the variance of the pixels inside the window. This paper includes the experimental results.

  • PDF

INVESTIGATING THE APPROPRIATENESS OF THE TACOM MEASURE - APPLICATION TO THE COMPLEXITY OF PROCEDURALIZED TASKS FOR HIGH SPEED TRAIN DRIVERS

  • Park, Jin-Kyun;Jung, Won-Dea;Ko, Jong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.115-124
    • /
    • 2010
  • According to wide-spread experience in many industries, a procedure is one of the most effective countermeasures to reduce the possibility of human related problems. Unfortunately, a systematic framework to evaluate the complexity of procedural tasks seems to be very scant. For this reason, the TACOM measure, which can quantify the complexity of procedural tasks, has been developed. In this study, the appropriateness of the TACOM measure is investigated by comparing TACOM scores regarding the procedural tasks of high speed train drivers with the associated workload scores measured by the NASA-TLX technique. As a result, it is observed that there is a meaningful correlation between the TACOM scores and the associated NASA-TLX scores. Therefore, it is expected that the TACOM measure can properly quantify the complexity of procedural tasks.

A Study of Control Chart for Skewness

  • Lee, Jung Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.4
    • /
    • pp.1-12
    • /
    • 1995
  • Sample skewness has not received much attention from researchers to design a control chart. In this paper, control charts based on two skewness measures are studied to control a manufacturing process. One skewness measure is the third central moment about mean, the other is the third L-moment which is a linear combination of order statistics. Since the exact sampling distributions of two skewness measures are unknown, empirical sampling distributions are studied using simulation. The sampling distributions are used to design control charts for skewness and performance of two skewness measures is compared.

  • PDF

Control Methodology of Inverse Response Process

  • Pratch, Tontirittiphol;Kiattisak, Kumwachara;Mongkol, Janchookiat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.48.6-48
    • /
    • 2002
  • in this paper, each methodology, e.g. normal single PID controller, direct synthesis method and inverse response compensator, will be compared to determine the best inverse response plant control method, by based on the appearance of the control performance and robustness from the simulation results. The flexibility of being able to maintain the system stability during the presence of plant model mismatch is one of the criteria to measure the robustness of overall control system. Once, plant has changed the condition, the model will need to be updated. Hence, the designed controller will not work properly. The caused of plant model mismatch is stayed by definition unknown but the most possib...

  • PDF

A Constant Air Volume Rate Control of Blower Using V/F Control (V/F제어를 이용한 송풍기의 일정한 공기압제어)

  • Jeong, Jong-Ho;Mun, Je-Yeon;Yun, Seo-Jin;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.100-102
    • /
    • 1998
  • This paper presents technique to control blower at constant air volume rate using V/F Control. Especially, this control method have not pressure sensors to measure because of using torque-speed relation based on the fan laws. Therefore, this technique is very simple and practical.