• Title/Summary/Keyword: Control maintenance techniques

Search Result 92, Processing Time 0.022 seconds

An Intelligent bridge with an advanced monitoring system and smart control techniques

  • Miyamoto, Ayaho;Motoshita, Minoru
    • Smart Structures and Systems
    • /
    • v.19 no.6
    • /
    • pp.587-599
    • /
    • 2017
  • This paper introduces an approach to the realization of an ICT-based bridge remote monitoring system that enables real-time monitoring and controlled adjustments for unexpected heavy loads and also for damaging earthquakes or typhoons. In this paper, an integrated bridge remote monitoring system called the "Intelligent Bridge", which consists of a stand-alone monitoring system (SMS) and a web-based Internet monitoring system(IMS), was developed for not only bridge maintenance but also as an application for a para-stressing bridge system. To verify the possibility of controlling the actual structural performance of an "Intelligent Bridge", a model 2-span continuous cable-stayed bridge with adjustable cables was constructed. The experimental results demonstrate that the implemented monitoring system supplies detailed and accurate information about bridge behaviour for further evaluation and diagnosis, and it also opens up prospects for future application of a web-based remote system to actually adjust in-service bridges under field conditions.

The study on the fault diagnosis expert system of dynamic system : a servey (대규모 dynamic 전력계통의 고장진단 expert system에 관한 연구)

  • 허성광;정학영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.579-583
    • /
    • 1988
  • As the power facilities grow up, the optimal operation and the best maintenance of power plant can not be overestimated too much, which can enhance the plant availability and reliability much further. In this respect, fault diagnosis methodologies of dynamic system which is time-varing and strongly nonlinear have been studied. On of them is to use algorithm which is based on time-invariant, linear system, but this is not so nice a method for applying to power Plant. Therefore, the study on other techniques using Artificial Intelligence (AI) is under way. In this paper, the existing ways of fault detection are surveyed and their problems are also discussed.

  • PDF

DMB+, a General Data Transmission Technique

  • Wang, Guoyu;Zhang, Hongsheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.5
    • /
    • pp.2043-2060
    • /
    • 2020
  • Developed from Digital Multimedia Broadcasting (DMB), DMB+ changes the application focus fundamentally. The plus symbol "+" indicates that DMB+ is no longer for digital radio/videos, instead it works as a general data transmission technique. The merits of wireless transmission, broad coverage, high quality, information security and low building/maintenance cost make DMB+ suitable for a wide range of applications with numerous terminals and users, such as public information release, alarm and administration etc. The concept of DMB+ base station enables DMB+ to be used in building independent networks and for remote control and management, as well as for Industry 4.0. DMB+ will access into a new field that till now has been dominated by communication techniques, will open a huge commercial opportunity.

Case Study of Design and Implementation for Hadoop-Based Integrated Facility Monitoring System (하둡 기반의 통합설비 모니터링시스템 설계 및 구현 사례 연구)

  • Kim, Sangrak;Jang, Gilsang;Cho, Chiwoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • SCADA and DCS that have performed automatic control and monitoring activities increase the productivity of enterprise in industries. In such systems, although their performance had been improved, there are still many deficiencies in predictive maintenance which can foresee the risk of any kinds of accidents. Because the data acquisition systems of main facilities are being distributed throughout the whole plant and therefore, integration of data obtained from the systems is very difficult. Accordingly, techniques that acquire meaningful information from the gathered data through realtime analysis still need to be improved. This paper introduces a developed facility monitoring system which can predict equipment failure and diagnose facility status through big data analysis to improve equipment efficiency and prevent safety accidents.

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

ACCELERATED CONSTRUCTION OF URBAN INTERSECTIONS WITH PORTLAND CEMENT CONCRETE PAVEMENT (PCCP)

  • Kamran M. Nemati
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.886-891
    • /
    • 2005
  • The frequent maintenance required on some asphalt concrete (AC) pavement sections has made reconstruction with Portland Cement Concrete Pavement (PCCP) a feasible alternative. However, many constructability issues need to be addressed in order to realize the full potential of this alternative. Accelerated paving encompasses three classes of activities: methods to accelerate the rate of strength gain, methods to minimize the construction time, and traffic control strategies to minimize user delay. Three major AC intersections with severe rutting problems were reconstructed with PCCP. The entire reconstruction of each intersection, including demolition of the AC pavement and its replacement with PCCP, took place over a period of three days, starting on Thursday evening and opening the intersection to the traffic on Sunday afternoon. This paper discusses the use of PCCP for accelerated reconstruction of major urban intersections with minimal user and traffic disruption, using innovative construction techniques and traffic management optimization principles and demonstrates that concrete pavements can be constructed efficiently and quickly.

  • PDF

ATM Cell Security Techniques Using OFB Mode on AES Block Cipher (AES 블록 암호에 OFB 모드를 적용한 ATM 셀 보안 기법)

  • Im, Sung-Yeal
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.6
    • /
    • pp.1237-1246
    • /
    • 2021
  • This paper is about Asynchronous Transfer Mode (ATM) cell security in which an Output Feedback (OFB) mode is applied to an AES block ciphers. ATM cells are divided into user data cells and maintenance cells, and each cell is 53 octets in size and consists of a header of 5 octets and a payload of 48 octets. In order to encrypt/decrypt ATM cells, the boundaries of cells must be detected, which is possible using the Header Error Control (HEC) field in the header. After detecting the boundary of the cell, the type of payload is detected using a payload type (PT) code to encrypt only the user cell. In this paper, a security method for ATM cells that satisfies the requirements of ISO 9160 is presented.

A Study on Control Flow Analysis Using Java Bytecodes in CTOC (CTOC에서 자바 바이트코드를 이용한 제어 흐름 분석에 관한 연구)

  • Yoo Weon-Hee;Kim Ki-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.1
    • /
    • pp.160-169
    • /
    • 2006
  • This paper describes the data structure for program analysis and optimization of bytecode level. First we create an extended CFG(Control Flow Graph). Because of the special properties of bytecode, we must adaptively extend the existing control flow analysis techniques. We build basic blocks to create the CFG and create various data that can be used for optimization. The created CFG can be tested for comprehension and maintenance of Java bytecode, and can also be used for other analyses such as data flow analysis. This paper implements CTOC's CTOC-BR(CTOC-Bytecode tRanslator) for control flow analysis of bytecode level. CTOC(Classes To Optimized Classes) is a Java bytecode framework for optimization and analysis. This paper covers the first part of the CTOC framework. CTOC-BR is a tool that converts the bytecode into tree form for easy optimization and analysis of bytecode in CTOC.

  • PDF

A case study on asymmetric deformation mechanism of the reserved roadway under mining influences and its control techniques

  • Li, Chen;Wu, Zheng;Zhang, Wenlong;Sun, Yanhua;Zhu, Chun;Zhang, Xiaohu
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.449-460
    • /
    • 2020
  • The double-lane arrangement model is frequently used in underground coal mines because it is beneficial to improve the mining efficiency of the working face. When the double-lane arrangement is used, the service time of the reserved roadway increases by twice, which causes several difficulties for the maintenance of the roadway. Given the severe non-uniform deformation of the reserved roadway in the Buertai Coal Mine, the stress distribution law in the mining area, the failure characteristics of roadway and the control effect of support resistance (SR) were systematically studied through on-site monitoring, FLAC 3D numerical simulation, mechanical model analysis. The research shows that the deformation and failure of the reserved roadway mainly manifested as asymmetrical roof sag and floor heave in the region behind the working face, and the roof dripping phenomenon occurred in the severe roof sag area. After the coal is mined out, the stress adjustment around goaf will happen to some extent. For example, the magnitude, direction, and confining pressure ratio of the principal stress at different positions will change. Under the influence of high-stress rotation, the plastic zone of the weak surrounding rock is expanded asymmetrically, which finally leads to the asymmetric failure of roadway. The existing roadway support has a limited effect on the control of the stress field and plastic zone, i.e., the anchor cable reinforcement cannot fully control the roadway deformation under given conditions. Based on obtained results, using roadway grouting and advanced hydraulic support during the secondary mining of the panel 22205 is proposed to ensure roadway safety. This study provides a reference for the stability control of roadway with similar geological conditions.

Comparison of DTC between two-level and three-level inverters for LV propulsion electric motor in ship (선박 추진용 저압 전동기에 대한 2레벨 및 3레벨 인버터의 직접토크제어 비교)

  • Ki-Tak RYU;Jong-Phil KIM;Yun-Hyung LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2024
  • In compliance with environmental regulations at sea and the introduction of unmanned autonomous ships, electric propulsion ships are garnering significant attention. Induction machines used as propulsion electric motor (PEM) have maintenance advantages, but speed control is very complicated and difficult. One of the most commonly used techniques for speed control is DTC (direct torque control). DTC is simple in the reference frame transformation and the stator flux calculation. Meanwhile, two-level and three-level voltage source inverters (VSI) are predominantly used. The three-level VSI has more flexibility in voltage space vector selection compared to the two-level VSI. In this paper, speed is controlled using the DTC method based on the specifications of the PEM. The speed controller employs a PI controller with anti-windup functionality. In addition, the characteristics of the two-level VSI and three-level VSI are compared under identical conditions. It was confirmed through simulation that proper control of speed and torque has been achieved. In particular, the torque ripple was small and control was possible with a low DC voltage at low speed in the three-level VSI. The study confirmed that the application of DTC, using a three-level VSI, contributes to enhancing the system's response performance.