• 제목/요약/키워드: Control cone

검색결과 261건 처리시간 0.037초

Directions of mandibular canal displacement in ameloblastoma: A computed tomography mirrored-method analysis

  • Evangelista, Karine;Cardoso, Lincoln;Toledo, Italo;Gasperini, Giovanni;Valladares-Neto, Jose;Cevidanes, Lucia Helena Soares;de Oliveira Ruellas, Antonio Carlos;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.17-25
    • /
    • 2021
  • Purpose: This study was performed to investigate mandibular canal displacement in patients with ameloblastoma using a 3-dimensional mirrored-model analysis. Materials and Methods: The sample consisted of computed tomographic scans of patients with ameloblastoma (n=10) and healthy controls (n=20). The amount of mandibular canal asymmetry was recorded as a continuous variable, while the buccolingual (yaw) and supero-inferior (pitch) directions of displacement were classified as categorical variables. The t-test for independent samples and the Fisher exact test were used to compare groups in terms of differences between sides and the presence of asymmetric inclinations, respectively (P<0.05). Results: The length of the mandibular canal was similar on both sides in both groups. The ameloblastoma group presented more lateral (2.40±4.16 mm) and inferior (-1.97±1.92 mm) positions of the mental foramen, and a more buccal (1.09±2.75 mm) position of the middle canal point on the lesion side. Displacement of the mandibular canal tended to be found in the anterior region in patients with ameloblastoma, occurring toward the buccal and inferior directions in 60% and 70% of ameloblastoma patients, respectively. Conclusion: Mandibular canal displacement due to ameloblastoma could be detected by this superimposed mirrored method, and displacement was more prevalent toward the inferior and buccal directions. This displacement affected the mental foramen position, but did not lead to a change in the length of the mandibular canal. The control group presented no mandibular canal displacement.

Effects of radiation therapy on the dislocation resistance of root canal sealers applied to dentin and the sealer-dentin interface: a pilot study

  • Pallavi Yaduka;Rubi Kataki;Debosmita Roy;Lima Das;Shachindra Goswami
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.22.1-22.12
    • /
    • 2021
  • Objectives: This study evaluated and compared the effects of radiation therapy on the dislocation resistance of AH Plus and BioRoot RCS applied to dentin and the sealer-dentin interface. Materials and Methods: Thirty single-rooted teeth were randomly assigned to 2 groups (n = 15 each): AH Plus (Dentsply DeTrey) and BioRoot RCS (Septodont). Each group was subdivided into control and experimental groups. The experimental group was subjected to a total radiation dose of 60 Gy. The root canals of all samples were cleaned, shaped, and obturated using the single-cone technique. Dentin slices (1 mm) were sectioned from each root third for the push-out test and scanning electron microscopy (SEM) was done to examine the sealer-dentin interface. The failure mode was determined using stereomicroscopy. Bond strength data were analyzed by the independent t-test, 1-way analysis of variance, and the Tukey post hoc test (α = 0.05). Results: Significantly lower bond strength was observed in irradiated teeth than non-irradiated teeth in the AH Plus group (p < 0.05). The BioRoot RCS group showed no significant reduction in bond strength after irradiation (p > 0.05) and showed a higher post-irradiation bond strength (209.92 ± 172.26 MPa) than the AH Plus group. SEM revealed slightly larger gap-containing regions in irradiated specimens from both groups. Conclusions: The dislocation resistance of BioRoot RCS was not significantly changed by irradiation and was higher than that of AH Plus. BioRoot RCS may be the sealer of choice for root canal treatment in patients undergoing radiation therapy.

Three-dimensional evaluation of the pharyngeal airway space in patients with anterior open bite

  • Seong-Sik Kim;Yong-Il Kim;Soo-Byung Park;Sung-Hun Kim
    • 대한치과교정학회지
    • /
    • 제53권6호
    • /
    • pp.358-364
    • /
    • 2023
  • Objective: This study aimed to three-dimensionally evaluate the pharyngeal airway space (PAS) of patients with anterior open bite (AOB) by using cone-beam computed tomography (CBCT) and compare the findings with those obtained in individuals with normal occlusion. Methods: The open bite group (OBG, n = 25) consisted of patients with an anterior overbite of -3 mm or less, while the control group (n = 25) consisted of age- and sex-matched individuals with an anterior overbite of 1-3 mm, Angle Class I malocclusion (1° ≤ point A-nasion-point B angle ≤ 4°), and a normodivergent profile (22° ≤ Frankfort mandibular plane angle ≤ 28°). After the CBCT data were reconstructed into a three-dimensional image, the PAS was segmented into four parts, and the volume of each part was measured. Pharyngeal airway length (PAL) and the area and transverse width of the part showing minimal constriction were also measured. Pearson's correlation analysis was used to evaluate the correlation between changes in the PAS and the amount of anterior overbite. Results: The OBG showed a significantly narrower airway space in the nasopharyngeal, hypopharyngeal, and total airway volumes. The OBG also showed a significantly smaller area and transverse width of the part with minimal constriction. The OBG showed a significantly longer PAL, but there was no correlation between the amount of anterior overbite and the changes in PAS. Conclusions: The PAS was associated with AOB. Patients with AOB had a narrower PAS and a smaller part showing minimal constriction.

선박소음에 관한 연구 -방음실에 의한 소음제어효과실험- (THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms-)

  • 박중희
    • 한국수산과학회지
    • /
    • 제9권3호
    • /
    • pp.215-221
    • /
    • 1976
  • 1976년 6월 10일부터 동년 8월 30일까지 본학 해양과학 연구소 하층 실험실에서 실험하였고 1975년 6월 7일에서 동년 8월 11일까지 약 2개월 동안에 풍양호, 척양호, 관악산호 등의 선박소음을 녹음한 테프로서 재생방음한 것을 음원으로 이용하였다. 이때 소음제어의 효과를 찾기 위해 A,B,C,D형의 실험용 직육면체인 방음실을 제작하여 실험실내에 배치하고 기관실소음과 발진기에 스피커를 연결해서 방음된 음압이 각방음제어실에 투과되는 음압 100분률과 또 각 방음제어실내에서 같은 조건으로 방음되는 경우에 자재와 형상이 다른 방음실내부 구조물에 따른 흡음효과를 조사 비교한 결과를 요약하면 다음과 같다. 1. 소음투과율은 실험실 외부음압이 60dB 일때 A형은 $69.7\%$였고 계속 10dB 증가함에 따라 $3.3\%$씩 증가하였고 D형에서는 $53.9\%$인 것이 10dB 증가함에 따라 $4.5\%$씩 증가했다. 2. 실험실인 외부음압이 100dB일 때 A,B,C,D형의 음압투과율은 81.6, 78.9, 75.3, $71.0\%$의 순으로 D형의 투과율이 낮아서 방음실로서는 D형이 가장 좋았다. 3. 대화에 지장이 없는 소음압은 75dB 이하이므로 A,B형을 제외하고 C,D형은 선박소음 제어실로서 유효했다. 4. 방음제어실내부 구조에 따른 흡음효과를 A,D형에서 비교하면 A형은 발진음일 때 거리 20cm에서 82dB로 가장 높고 80cm에서 76dB로 가장 낮았으며 100cm에서 77dB였고 140cm에서 78dB 정도 다시 증가해 반사음 현상이 일어났다. D형은 발진음일 때 거리 20cm에서 A와 같이 82dB였는데 80cm에서 72.5dB, 100cm에서 73dB, 140cm서에는 67dB로 A보다 12dB가 낮았다. 선박소음도 거리 20cm에서 A형은 77.5dB, D형은 77dB였는데 140cm에서는 A형이 74dB, D형이 63dB로 11dB의 차이로 D형이 낮아 역시 흡음효과가 A형 보다 D형이 좋았고 완벽한 무향실로서 반사음의 영향은 찾아 볼 수 없었다. 5. 매우 낮은 발진음일 때 흡음관계를 1000Hz를 기준삼아 보면 거리 20cm에서 C형은 44.7dB, D형은 45.4dB로 C형이 0.3dB로 악간 낮았으나 140cm에서 C,D형 모두가 44.3dB로서 같았다. 값싼 자재로서도 C형이 가장 흡음효과가 좋았다.

  • PDF

원격감지 성페로몬트랩을 이용한 멸강나방(Mythimna separata) 성충 예찰 (Monitoring of Mythimna separata Adults by Using a Remote-sensing Sex Pheromone Trap)

  • 정진교;서보윤;조점래;김용
    • 한국응용곤충학회지
    • /
    • 제52권4호
    • /
    • pp.341-348
    • /
    • 2013
  • 비래해충인 멸강나방 성충의 발생을 실시간으로 예찰하기 위하여, 성페로몬 트랩에 원격감지장치를 설치한 트랩의 운용 효율성을 검정하였다. 원격감지트랩은 콘트랩 기반에 곤충의 유입을 광차단으로 감지하는 센서부, 신호전송부, 태양열기반의 전력공급부, 트랩 지지대, 웹페이지 기반의 자료수집부로 구성되었다. 연구과정에서 멸강나방 수컷 성충의 밤 시간대 포획의 일일주기성을 이용한 신호감지 시간대 축소, 신호발생 프로그램 조절, 1시간 간격의 전송간격, 신호전송 프로그램 변형 등을 통해 포획 나방수와 감지신호 발생 수의 격차를 줄여 최종적으로 신호 정확도를 92% 이상으로 개선하였다. 또한 실제 멸강나방 성충의 발생양상과 원격감지트랩에서의 신호 발생양상의 상관계수가 0.98이상으로 원격감지트랩에서의 신호 발생이 멸강나방 발생 양상을 정확하게 반영하는 것으로 나타났다. 2011~2012년 멸강나방은 연중 여러 번 발생되는 것이 관찰되었는데, 모두 짧은 기간 동안 발생되어 가파른 피크가 특징이었다.

Whole pelvic intensity-modulated radiotherapy for high-risk prostate cancer: a preliminary report

  • Joo, Ji Hyeon;Kim, Yeon Joo;Kim, Young Seok;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Su Ssan;Park, Jin-Hong;Jeong, Yuri;Ahn, Hanjong;Kim, Choung-Soo;Lee, Jae-Lyun;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.199-205
    • /
    • 2013
  • Purpose: To assess the clinical efficacy and toxicity of whole pelvic intensity-modulated radiotherapy (WP-IMRT) for high-risk prostate cancer. Materials and Methods: Patients with high-risk prostate cancer treated between 2008 and 2013 were reviewed. The study included patients who had undergone WP-IMRT with image guidance using electronic portal imaging devices and/or cone-beam computed tomography. The endorectal balloon was used in 93% of patients. Patients received either 46 Gy to the whole pelvis plus a boost of up to 76 Gy to the prostate in 2 Gy daily fractions, or 44 Gy to the whole pelvis plus a boost of up to 72.6 Gy to the prostate in 2.2 Gy fractions. Results: The study cohort included 70 patients, of whom 55 (78%) had a Gleason score of 8 to 10 and 50 (71%) had a prostate-specific antigen level > 20 ng/mL. The androgen deprivation therapy was combined in 62 patients. The biochemical failure-free survival rate was 86.7% at 2 years. Acute any grade gastrointestinal (GI) and genitourinary (GU) toxicity rates were 47% and 73%, respectively. The actuarial rate of late grade 2 or worse toxicity at 2 years was 12.9% for GI, and 5.7% for GU with no late grade 4 toxicity. Conclusion: WP-IMRT was well tolerated with no severe acute or late toxicities, resulting in at least similar biochemical control to that of the historic control group with a small field. The long-term efficacy and toxicity will be assessed in the future, and a prospective randomized trial is needed to verify these findings.

농업용 포크리프트의 구동력 및 운동저항 예측을 위한 모델링 기법 개발 (Development of Modeling Technique for Prediction of Driving Force and Kinetic Resistance of Agricultural Forklift)

  • 조재현;김준태;정진형;장영윤;박원엽;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.299-305
    • /
    • 2019
  • 본 연구는 고령화와 젊은층의 이탈로 인한 농경사회에서 고령 및 여성 인력의 애로사항을 해결해주기 위해 시작되었다. 기존에 나와있는 농업용 고소리프트의 경우 전문 자격증 및 조작의 어려움과 평지가 아닌 불균형적인 도로 혹은 작업환경에 노출된 위험성과 여성들도 쉽고 효율적으로 생산적 농업을 할 수 있도록 하기 위하여 선행연구를 바탕으로 진행하였다. 먼저 농업용 포크리프트의 목적인 물체를 이용한 견인 성능 예측 모델을 통하여 시뮬레이션을 진행하고, 견인 성능 모델 수식을 이용하여 실험이 진행되고 있는 경남 김해시의 토양(점착력 34.125kPa, 내부마찰각 35.294deg, 외부마찰각 13.620deg, 부착력 5.750kPa, 평균 원추지수 0-15cm cl, 1001.8kPa)에 맞추었다. 시뮬레이션용 포크리프트의 경우 농업용 전동식 포크리프트의 구동력 및 운동저항 예측 모델링을 수식화하고 이를 바탕으로 모터 제어 드라이브는 AC모터 전용 드라이브인 1232E 모델을 적용, 프로그래밍을 통해 두 개의 드라이버를 각각 마스터와 슬레이브로 구분지어 구동할 수 있도록 하였고 메인 PCB에는 모터구동, 유압구동, 각종 출력을 제어할 수 있도록 시뮬레이션용 모델을 제작하였다. 제작된 시뮬레이션용 모델은 현재 지속적인 시뮬레이션과 수정 및 보완을 진행하고 있으며, 추후 본 연구를 바탕으로 보다 안전하고 효율성이 뛰어난 농업용 전동식 포크리프트의 개발을 위하여 연구를 지속할 예정이다.

치의학 교육을 위한 프로토타입 시뮬레이터의 개발 (Development of a prototype simulator for dental education)

  • 김미엘;심재훈;에인 몬;김명주;박영석;권호범;박재흥
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.257-267
    • /
    • 2023
  • 목적. 이 연구의 목적은 치의학 교육을 위한 프로토타입 로봇 시뮬레이터를 제작하고, 하악운동을 시뮬레이션 할 수 있는지 여부를 테스트하며, 치과실습 중 자극에 대한 시뮬레이터의 반응 가능성을 평가하는 것이었다. 재료 및 방법. 가상 시뮬레이터 모델은 cone-beam computed tomography (CBCT) 데이터를 사용하여 경조직을 구획화한 후 제작되었다. 시뮬레이터의 프레임은 polylactic acid (PLA) 소재를 사용하여 3D 프린팅 되었으며, 덴티폼과 실리콘 얼굴 스킨을 장착하여 모델을 형성하였다. 서보 액추에이터는 시뮬레이터의 움직임을 제어하는데 사용되었고, 다양한 센서들로 시뮬레이터의 반응을 생성하였다. 수위 센서가 반응하는 물의 양을 측정하기 위해 수위테스트가 수행되었다. 또한, 컴퓨터 시뮬레이션과 실제 모델을 통해 시뮬레이터의 하악운동과 하악운동 범위를 테스트하였다. 결과. 프로토타입 로봇 시뮬레이터는 작동 장치, 전기 장치가 있는 상반신, 턱관절을 포함하는 머리 및 덴티폼으로 구성되었다. 시뮬레이터의 턱관절은 회전 및 병진 운동을 구현하면서 2자유도를 구동할 수 있었다. 수위 테스트에서 수위 센서의 특정 임계값은 10.35 ml였다. 컴퓨터 시뮬레이션과 실제 모델 모두에서 인간의 움직임을 모방하였고, 시뮬레이터의 하악운동 시 개구범위는 50 mm였다. 결론. 효율성과 안정성을 개선하기 위해서는 더 많은 발전이 필요하지만, 본 상반신 프로토타입의 시뮬레이터는 향후 치과실습 교육에 잠재적으로 유용할 것으로 기대된다.

측방가압충전시 Heated Spreader 사용유무가 근관밀폐에 미치는 영향 (INFLUENCE OF HEATED SPREADER ON THE SEALING ABILITY OF LATERAL CONDENSATION)

  • 정원균;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.222-232
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of heated spreader on the sealing ability of lateral condensation, compared with regular cold spreader. Forty two extracted human teeth with single canal were randomly placed into 3 experimental groups, and four additional teeth were used as positive and negative controls. Each group was prepared with Ni-Ti Profile #40 using step-down technique and obturated with standardized colored gutta-percha cone by standard(cold) lateral condensation technique, warm lateral condensation technique with Endotec and hot spreader soaked in glass bead sterilizer, each with Sealapex sealer. Control groups were not obturated, but prepared. After 2 days in 2% methylene blue, the teeth were invested and made into transparent resin blocks. And then, each block was sectioned horizontally with microtome at 1, 2, 3, 4, 5 mm levels from the apex. The linear extent of dye penetration was examined with stereomicroscope at ${\times}$20 magnification. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using an analysis of variance(ANOVA) and Scheffe test. The results were as follows ; 1. All experimental groups produced the apical microleakage. 2. The mean leakage was 1.57${\pm}$0.76mm for cold spreader group, 0.86${\pm}$0.95mm for Endotec spreader group, and 0.64${\pm}$0.93mm for hot spreader group. The difference between hot spreader group and cold spreader group was statistically significant(p<0.05). 1. At the 1 mm level, the mean ratio of area of gutta-percha was 74.58${\pm}$13.15(%) for cold spreader group, 65.42${\pm}$14.62(%) for Endotec spreader group, and 80.72${\pm}$14.63(%) for hot spreader group. There was statistically significant difference between hot spreader group and Endotec spreader group(p<0.05). 2. At the 2mm level, the mean ratio of area of gutta-percha was 87.86${\pm}$11.22(%) for cold spreader group, 66.55${\pm}$14.02(%) for Endotec spreader group, and 92.93${\pm}$7.24(%) for hot spreader group. There was statistically significant difference between Endotec spreader group and other two spreader groups(p<0.05). 3. At the level 3, 4, 5 mm, there was no statistically significant difference between each group. Within the limits of the results of this experiment, warm lateral condensation technique with hot spreader soaked in a glass bead sterilizer demonstrated favorable apical sealing effect and improved density of gutta-percha mass. Thus, it is thought that this obturation technique is effective for clinical use and beneficial to reduce condensation forces, also economical and easy. Lateral condensation, Heated spreader, canal sealing, Microleakage.

  • PDF

니트릴고무/타이어고무분말(GTR)를 이용한 발포체의 발포 및 난연 특성에 관한 연구 (Foaming Properties and Flame Retardancy of the Foams Based on NBR/GTR Compounds)

  • 문성철;조병욱;최재곤
    • Elastomers and Composites
    • /
    • 제37권3호
    • /
    • pp.159-169
    • /
    • 2002
  • 본 연구에서는 acrylonitrile-butadiene rubber(NBR)/타이어고무분말(Ground Tire Rubber, GTR) 블렌드계의 발포체를 제조하고, 이들의 난연성을 증진시키고자 하였다. 그 결과 난연제 중 유기인 화합물 및 무기금속 수산화물의 함량 증가에 따라 난연성이 증진됨을 확인할 수 있었다. 유기인 화합물의 경우 함량 증가에 따라 한계산소지수(LOI)가 증가하고, 열 방출 속도(HRR) 및 유효 연소열(EHC)이 감소하는 반면에 CO 방출률(량) 및 역기밀도가 증가함을 확인 할 수 있었다. 무기금속 수산화물은 함량 증가에 따라 난연효과 뿐만 아니라 열기발생 억제효과를 동시에 가짐으로써 LOI, HRR, EHC가 유기인 화합물 첨가에서와 같은 경향성을 보여주었지만 CO 방출률(량) 및 연기밀도에 있어서는 유기인 화합물 첨가에서와 상이하게 감소하였다. 그리고 난연성을 판단함에 있어 중요한 변수들인 열 방출속도, 유효 연소열, 무게감소, 한계산소지수간의 상관관계를 확인하였는데, A-HRR과 LOI가 증가함에 따라 질량손실이 각각 증가 혹은 감소하는 뚜렷한 경향성을 확인하였다. 이로써 NBR/GTR의 조성비기 $100{\sim}80/0{\sim}20 wt.%$이고 고무/난연제의 조성비가 $1/1.55{\sim}3.60 wt.%$일 때, 원활한 핵의 생성 및 cell의 성장으로 인해 균일한 closed cell 및 semi-closed cell을 보여주었다. 또한 $225{\sim}250 %$의 발포율을 보이며, 낯은 HRR과 높은 LOI($28.0{\sim}39.3$)를 갖는 난연성 및 발포성이 우수한 발포체를 얻을 수 있었다.