Study for improvement of zero-cross detector of control element drive mechanism control system in PWR (경수로 제어봉구동장치제어계통의 영점위상탐지기 성능개선에 관한 연구)

  • 김병문;이병주;한상준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.609-611
    • /
    • 1996
  • Zero-Cross Detector makes pilot signal to control the power to CEDM(Control Element Drive Mechanism). Existing Zero-Cross Detectors has had a problem which can cause unexpected reactor trip resulted from fluctuating frequency of input signal coming from M/G Set. The existing Zero-Cross Detector can't work properly when power frequency is varying because it was designed to work under stable M/G Set operation, and produces wrong pilot signal and output voltage. In this report the Zero-Cross Detector is improved to resolve voltage fluctuating problem by using new devices such as digital noise filtering circuit, variable cycle compensator and alarm circuit. And through the performance verification it shows that new circuit is better than old one. If suggested detector is applied to plant, it is possible to use it under House Load Operation because stable voltage can be generated by new Zero-Cross Detector.

  • PDF

A Study on the Improvement of the Control Circuit Design of Controllable Pitch Propeller (가변피치프로펠러의 제어회로 설계 개선에 관한 연구)

  • Kim, Dong-Young;Kang, Gu-Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.52-60
    • /
    • 2019
  • The control circuit of the CPP applied to FFX Batch-I and LST-II may be capable of generating a backward pitch even when the grounding phenomenon occurs in the other system. The purpose of this study was to improve the CPP control circuit to maintain the pitch even in the event of grounding. Since the CPP control circuit changes the propeller angle with the voltage difference input, it has a design structure that can be vulnerable if the input voltage fluctuates instantaneously. In order to solve the above problem, a terminating resistor is applied to the end of the control wire and a signal converter is applied between the control wires, as a way to improve the CPP control circuit design. In order to verify that there is no problem in improving the CPP control circuit design, the CPP pitch change control was tested in the actual sailing commissioning with LST-II. Since the command pitch value and the feedback pitch value are very similar to each other, it is confirmed that the CPP control circuit is suitable for the control signal transmission because there is no problem in transmitting the control signal.

Design of On-Chip Solar Energy Harvesting Circuit with MPPT Control (MPPT 제어 기능을 갖는 온칩 빛에너지 하베스팅 회로 설계)

  • Yoon, Eun-Jung;Park, Jun-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.425-428
    • /
    • 2011
  • This paper presents a micro-scale solar energy harvesting circuit with a simple MPPT control. Solar Energy is harvested using a small off-chip PV cell generating output voltages under 0.5V instead of an on-chip PV cell. A simple MPPT is implemented using a pilot PV cell and utilizing the relationship between the open-circuit voltage of a PV cell ($V_{OC}$) and its MPP voltage ($V_{MPP}$). With applying the MPPT control, the designed circuit delivers the MPP voltage to load even though the loads is heavy such that the load circuit can operate properly. The proposed circuit is designed in TSMC 0.18um CMOS process.

  • PDF

Design of Vibration Harvesting Circuit using the MPPT control (MPPT 제어 기능을 갖는 진동에너지 하베스팅 회로 설계)

  • Park, Joon-Ho;Yun, Eun-Jung;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.392-395
    • /
    • 2011
  • In this paper, a vibration energy harvesting circuit using the piezoelectric element has been designed. MPPT (maximum power point tracking control) control function has been implemented to deliver the maximum power to the load by using the electric power-voltage characteristic of the piezoelectric element. The designed MPPT circuit traces the maximum power point by sampling periodically the open circuit voltage of the full wave rectifier circuit and delivers the maximum available power to the load. The vibration energy harvesting circuit is designed with $0.18{\mu}m$ CMOS process. The maximum power efficiency is 91%, and the chip area except pads is $1,100{\mu}m{\times}730{\mu}m$.

  • PDF

Active Linear Modeling of Cochlear Biomechanics Using Hspice

  • Jarng Soon Suck;Kwon You Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.77-86
    • /
    • 2005
  • This paper shows one and two dimensional active linear modeling of cochlear biomechanics using Hspice. The advantage of the Hspice modeling is that the cochlear biomechanics may be implemented into an analog Ie chip. This paper explains in detail how to transform the physical cochlear biomechanics to the electrical circuit model and how to represent the circuit in Hspice code. There are some circuit design rules to make the Hspice code to be executed properly.

A Study on the AC Pow a Study on the AC Power Control Circuit by Combining PWM and Phase Control (PWM과 입상제어의 조합에 의한 교류전력 제어회로에 관한 연구)

  • 정화균;김이곤;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.84-95
    • /
    • 1991
  • Mostly, phase control method is used to control the single phase AC power. The phase control method has some advantages such as ease to control and simple configuration. But the retardation of firing angle causes a lagging current even if load is purely resistive. So phase control causes a lagging power factor and a low efficiency at the input side in comparing with the system without switching device. A new PWM control method which can improve these defects for single phase AC power control circuit is proposed in this paper. The performances of the single phase AC power control circuit using the proposed method was investigated theoretically. Both power factor and waveform of load current can be improved better than those of the conventional methods.

  • PDF

A study on the construction of nic circuit and ists application to oscilation circuit (Nic 회로의 구성 및 발진회로에의 응용에 관한 연구)

  • 김명기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.6
    • /
    • pp.16-24
    • /
    • 1974
  • In this paper the method of constructing short and open stable voltage inversion negative immittance converter (VNIC) circuits is proposed according to simplified equivalent models witch consist of a parameter control circuit, and a voltage or a current control circuit. VNIC characteristics can be obtained as gate voltage of common gate connection is controlled by the output of the parameter control circuit corresponding to its input. Constructed circuits are analysed, and the experimental results are compared and cheeked with the calculated results. Errors are found less than 11%. Oscillation behavior of constructed VNIC oscillator is compared with that of negative resistance oscillator.

  • PDF

A CMOS Temperature Control Circuit for Direct Mounting of Quartz Crystal on a PLL Chip (온 칩 수정발진기를 위한 CMOS 온도 제어회로)

  • Park, Cheol-Young
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.2
    • /
    • pp.79-84
    • /
    • 2007
  • This papar reports design and fabrication of CMOS temperature control circuit using MOSIS 0.25um-3.3V CMOS technology. The proposed circuit has a temperature coefficient of $13mV/^{\circ}C$ for a wide operating temperature range with a good linearity. Furthermore, the temperature coefficient of output voltage can be controlled by adjusting external bias voltage. This circuit my be applicable to the design of one-chip IC where quartz crystal resonator is mounted on CMOS oscillator chips.

  • PDF

Effects of Task-Oriented Circuit Class Training on Improves Performance of Locomotor in Disabled Persons after Stroke (과제-지향 순회 훈련이 뇌졸중 장애인의 이동 능력에 미치는 효과)

  • Kim, Soo-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.447-454
    • /
    • 2011
  • Purpose : The purpose of this study was to identify the effects of circuit class training on the performance of locomotor tasks in chronic stroke. Methods : The study included 45 patients with chronic stroke randomly divided into experimetal group and control group. Both groups participated in exercise classes three times a week for 8weeks. The experimental group had 10 workstation of circuit class designed to improve walking. The control group practiced fitness exercises by equipment in health center. Walking performance was assessed by measuring walking speed(timed 10-meter walk and TUG), GAITRite analysis and peak vertical ground reaction force through the affected foot during walking. Results : The experimental group demonstrated significant improvement(p<.05) compared with the control group in 10-meter walking and vertical ground reaction force after training. The experimental group showed significant improvements in the walking velocity and cadence by GAITRite system(p<.05). Conclusion : Task- oriented circuit class training leads to improvements in locomotor function in chronic stroke. Further studies are necessary to occur in usual environments to improve walking performance.

A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load (전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.