• 제목/요약/키워드: Control center

검색결과 15,392건 처리시간 0.051초

Method for Screening and Confirming Meldonium in Human Urine by High-Resolution Mass Spectrometry and Identification of Endogenous Interferences for Anti-Doping Testing

  • Kim, Yongseok;Jeong, Dawon;Min, Hophil;Sung, Changmin;Park, Ju-hyung;Son, Junghyun;Lee, Kang Mi;Kim, Ho Jun;Lee, Jaeick;Kwon, Oh-Seung;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • 제8권2호
    • /
    • pp.39-43
    • /
    • 2017
  • Meldonium is a drug for treating ischemia by expanding the arteries but it can also enhance the performance of sports players. The World Anti-Doping Agency (WADA) has included it in the list of prohibited substances since 2016. Meldonium is one of the challenging substances for anti-doping testing because it is difficult to recover by general liquid-liquid or solid phase extraction due to its permanent charge and high polarity. Therefore, high-performance liquid chromatography (HPLC) is currently used by injecting a diluted urine sample (known as the "dilute-and-shoot" strategy). There is no loss of target compounds in the extraction/cleanup procedure but its high matrix effect could interfere in their separation or detection from the endogenous urinary compounds. We report a single method using high-resolution mass spectrometry that can be used for both screening and confirmation, which follows the "dilute-and-shoot" strategy. In this method, the endogenous compounds' interfering peaks in the mass spectrum are separated at a high resolution of FWHM 140,000, and the results are suitable for substance detection following the WADA guidelines. The interferences in the obtained mass spectrum of the urine matrix are identified as acetylcholine, lysine, and glutamine by further analysis and database searching. Validation of the method is performed in routine anti-doping testing, and the limit of detection is 50 ng/mL. This method uses simple sample preparation and a general reverse phase HPLC column, and it can be easily applied to other substances.

Longitudinal Spacing Control of Vehicles in a Platoon

  • No, Tae-Soo;Chong, Kil-To
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권2호
    • /
    • pp.92-97
    • /
    • 2000
  • The Lyapunov stability theorem is used to derive a control law that can be used to control the spacing between vehicles in a platoon. A third order system is adopted to model the vehicle and power-train dynamics. In addition, the concept of

  • PDF

A robust controller design for rapid thermal processing in semiconductor manufacturing

  • Choi, Byung-Wook;Choi, Seong-Gyu;Kim, Dong-Sung;Park, Jae-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.79-82
    • /
    • 1995
  • The problem of temperature control for rapid thermal processing (RTP) in semiconductor manufacturing is discussed in this paper. Among sub=micron technologies for VLSI devices, reducing the junction depth of doped region is of great importance. This paper investigates existing methods for manufacturing wafers, focusing on the RPT which is considered to be good for formation of shallow junctions and performs the wafer fabrication operation in a single chamber of annealing, oxidation, chemical vapor deposition, etc., within a few minutes. In RTP for semiconductor manufacturing, accurate and uniform control of the wafer temperature is essential. In this paper, a robustr controller is designed using a recently developed optimization technique. The controller designed is then tested via computer simulation and compared with the other results.

  • PDF

Quitline Activity in China

  • Wang, Jijiang;Nan, Yi;Yang, Yan;Jiang, Yuan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권sup2호
    • /
    • pp.7-9
    • /
    • 2016
  • In order to help smokers quit easier, China has started to provide quitline service since 2004. There are two models for Chinese quitline service-the National Quitline Model, which provides only cessation service to smokers, and the 12320 Hotline Model, which integrates cessation counseling into public health hotline service and is currently adapted in public health hotlines in 28 provinces. A protocol of 4 counseling calls is used by 12320 Hotline. Three-month abstinence rate for clients is about 20%. The fact that most smokers who attempted quit don't seek cessation help or quitline service is not well known by the public are major constraints for quitline service in China. Effective advocating campaign should be implemented to propagate quitline. Diverse protocols targeting different subpopulation will also need to be developed to better service the public.

제어봉 제어 시스템의 전력함 PCB 카드에 대한 신뢰성 예측 (THE RELIABILITY PREDICTION OF PCB CARDS OF POWER CABINET OF CONTROL ROD CONTROL SYSTEM)

  • 정해원;서중석;육심균;남정한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2028-2030
    • /
    • 2003
  • This paper describes the results of reliability prediction analysis of control rod control system, which is being developed as part of KNICS project. The results of reliability prediction indicate MTBF(Mean Time Between Failure) of cards for control rod control system. A purpose of reliability prediction is to evaluate MTBF of cards, identify the design drawbacks of cards, and propose design improvement to a designer to help design the more reliable control rod control system. This reliability prediction analysis used the the part count and part stress method in the basis of MIL-HDBK-217F.

  • PDF

Development of Lateral Flow Immunoassay for Antigen Detection in Human Angiostrongylus cantonensis Infection

  • Chen, Mu-Xin;Chen, Jia-Xu;Chen, Shao-Hong;Huang, Da-Na;Ai, Lin;Zhang, Ren-Li
    • Parasites, Hosts and Diseases
    • /
    • 제54권3호
    • /
    • pp.375-380
    • /
    • 2016
  • Angiostrongyliasis is difficult to be diagnosed for the reason that no ideal method can be used. Serologic tests require specific equipment and are not always available in poverty-stricken zone and are time-consuming. A lateral flow immunoassay (LFIA) may be useful for angiostrongyliasis control. We established a LFIA for the diagnosis of angiostrongyliasis based on 2 monoclonal antibodies (mAbs) against antigens of Angiostrongylus cantonensis adults. The sensitivity and specificity were 91.1% and 100% in LFIA, while those of commercial ELISA kit was 97.8% and 86.3%, respectively. Youden index was 0.91 in LFIA and 0.84 in commercial ELISA kit. LFIA showed detection limit of 1 ng/ml of A. cantonensis ES antigens. This LFIA was simple, rapid, highly sensitive and specific, which opened an alternative approach for the diagnosis of human angiostrongyliasis.

A contact investigation after exposure to a child with disseminated tuberculosis mimicking inflammatory bowel disease

  • Kim, Dongsub;Lee, Sodam;Kang, Sang-Hee;Park, Mi-Sun;Yoo, So-Young;Jeon, Tae Yeon;Choi, JoonSik;Kim, Bora;Choi, Jong Rim;Cho, Sun Young;Chung, Doo Ryeon;Choe, Yon Ho;Kim, Yae-Jean
    • Clinical and Experimental Pediatrics
    • /
    • 제61권11호
    • /
    • pp.366-370
    • /
    • 2018
  • Purpose: Tuberculosis (TB) is one of the most important diseases that cause significant mortality and morbidity in young children. Data on TB transmission from an infected child are limited. Herein, we report a case of disseminated TB in a child and conducted a contact investigation among exposed individuals. Methods: A 4-year-old child without Bacille Calmette-$Gu{\acute{e}}rin$ vaccination was diagnosed as having culture-proven disseminated TB. The child initially presented with symptoms of inflammatory bowel disease, and nosocomial and kindergarten exposures were reported. The exposed individuals to the index case were divided into 3 groups, namely household, nosocomial, or kindergarten contacts. Evaluation was performed following the Korean guidelines for TB. Kindergarten contacts were further divided into close or casual contacts. Chest radiography and tuberculin skin test or interferon-gamma-releasing assay were performed for the contacts. Results: We examined 327 individuals (3 household, 10 nosocomial, and 314 kindergarten contacts), of whom 18 (5.5%), the brother of the index patient, and 17 kindergarten children were diagnosed as having latent TB infection (LTBI). LTBI diagnosis was more frequent in the children who had close kindergarten contact with the index case (17.1% vs. 4.4%, P=0.007). None of the cases had active TB. Conclusion: This is the first reported case of TB transmission among young children from a pediatric patient with disseminated TB in Korea. TB should be emphasized as a possible cause of chronic diarrhea and failure to thrive in children. A national TB control policy has been actively applied to identify Korean children with LTBI.

Simultaneous Determination of Synthetic Phosphodiesterase-5 Inhibitors in Dietary Supplements by Liquid Chromatography-High Resolution/Mass Spectrometry

  • Kim, So-Hee;Kim, Ho-Jun;Son, Jung-Hyun;Jeon, Byoung-Wook;Jeong, Eun-Sook;Cha, Eun-Ju;Lee, Jae-Ick
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.50-53
    • /
    • 2012
  • After success of sildenafil for the treatment of erectile dysfunction, a large number of its analogues have been approved from FDA. Recently, the illegal dietary supplements which include sildenafil, vardenafil, tadalafil, or analogues of these drugs as ingredient have been widely distributed. Therefore, the determination of the residue of synthetic phosphodiesterase- 5 (PDE-5) inhibitors in dietary supplements is highly required due to indiscriminate and unintentional overdose caused nausea, chest pains, fainting and irregular heartbeat. In this paper, we report a rapid and sensitive analytical method for the simultaneous determination of nine phosphodiesterase-5 inhibitors by liquid chromatography-high resolution mass spectrometry. The present method was found to be accurate and reproducible with 40 ${\mu}g$/g of the limit of quantification for the nine PDE-5 inhibitors. The developed method can be successfully applied to the analysis of the seven illegal dietary supplements.

ESP의 전단 변형을 이용한 원격 순응 중심 장치의 순응 중심 조절 방법에 관한 실험적 고찰 (An experimental study on adjusting mechanism of Remote Center Compliance for assembly robots with shear stress control of Elastomer Shear Pads(ESP))

  • 이상철
    • 제어로봇시스템학회논문지
    • /
    • 제13권9호
    • /
    • pp.910-914
    • /
    • 2007
  • In this paper, an experimental study is performed to adjust position of compliance center of Elastomer Shear Pad Remote Center Compliance (ESP RCC) device, which is used on precise peg in hole process. In the study, variation of the lateral/axial stiffness of the ESP is proposed as a control parameter to adjust the position of compliance center of the ESP RCC. The variation of the stiffness of the ESP is achieved by controlling the shear stress of the ESP. To control the shear stress of the ESP, position of top side of the ESP is changed while remaining bottom side of the ESP is fixed on the RCC plate. To evaluate effect of the proposed idea, stiffness variations of the ESP on various shear stresses are measured, and variation of the compliance center is measured with the ESP RCC that can control the position of compliance center by using the shear stress. The measured data shows unique characteristics that have not been shown in other types of ESP VRCCs.

Choosing Optimal STR Markers for Quality Assurance of Distributed Biomaterials in Biobanking

  • Chung, Tae-Hoon;Lee, Hee-Jung;Lee, Mi-Hee;Jeon, Jae-Pil;Kim, Ki-Sang;Han, Bok-Ghee
    • Genomics & Informatics
    • /
    • 제7권1호
    • /
    • pp.32-37
    • /
    • 2009
  • The quality assurance (QA) is of utmost importance in biobanks when archived biomaterials are distributed to biomedical researchers. For sample authentication and cross-contamination detection, the two fundamental elements of QA, STR genotyping is usually utilized. However, the incorporated number of STR markers is highly redundant for biobanking purposes, resulting in time and cost inefficiency. An index to measure the cross-contamination detection capability of an STR marker, the mixture probability (MP), was developed. MP as well as other forensic parameters for STR markers was validated using STR genotyping data on 2328 normal Koreans with the commercial AmpFlSTR kit. For Koreans, 7 STR marker (D2S1338, FGA, D18S51, D8S1179, D13S317, D21S11, vWA) set was sufficient to provide discrimination power of ${\sim}10^{-10}$ and cross-contamination detection probability of ${sim}1$. Interestingly, similar marker sets were obtained from African Americans, Caucasian Americans, and Hispanic Americans under the same level of discrimination power. Only a small subset of commonly used STR markers is sufficient for QA purposes in biobanks. A procedure for selecting optimal STR markers is outlined using STR genotyping results from normal Korean population.