• Title/Summary/Keyword: Control Volume Energy

Search Result 294, Processing Time 0.026 seconds

Protective Effect of the Water Extract of Tissue Cultured Root of Wild Ginseng Against Doxorubicin Toxicity (배양산삼 추출액의 Doxorubicin 독성 완화 효과)

  • Choi, Kyung-Un;Lee, Pyeong-Jae;Kim, Ho-Hyun
    • The Korea Journal of Herbology
    • /
    • v.24 no.3
    • /
    • pp.13-19
    • /
    • 2009
  • Objectives : This study was aimed to define the protective effect of Tissue Cultured Root of Wild Ginseng (CWG) against doxorubicin (Doxo) toxicity, and investigate the anti-tumor synergic effect of CWG in combination with Doxo in tumor-bearing C57BL/6 mice. Methods : Tumor-bearing mice were established by single inoculation with B16/F10 melanoma cells (2$\times$10$^6$/ml) subcutaneously. Tumor-bearing mice (tumor volume between 50-100 mm$^3$) were selected and divided them into control, Doxo, and Doxo+CWG group. Mice of Doxo group were received with Doxo (4 mg/kg of B.W.) intraperitoneally at 0, 4, 8 days after starting the experiment. Mice of Doxo+CWG group were received CWG water extract during 12 days in combination with Doxo treatment. The body weight, tumor volume, tumor weight, and organ weight (heart, liver, kidney, and testis) were measured. And serum SPK, GOT and creatinine values were analysed. Results : The volume and weights of tumor masses in Doxo group were decreased significantly compared with the those of control group. And the those of Doxo+CWG group were not significantly different from the those of Doxo group. Whereas the weight of body, liver, kidney and testis in Doxo+CWG group were increased significantly compared with the those of Doxo group. The level of serum CPK and GOT in Doxo group were increased compared with the those of control group. But the value of Doxo+CWG group were decreased significantly compared with the values of Doxo group. Conclusions : These results suggest that CWG has protective effect against doxorubicin toxicity. And these effect is guessed that is caused in augmentation of vital energy.

Flow Control Analysis of S-duct Diffuser Inlet

  • Lian, Xiaochun;Zhang, Lifen;Wu, Dingyi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.157-159
    • /
    • 2008
  • An numerical investigation of the flow characteristics inside a diffusing S-duct inlet with and without vortex generators(VGs) was conducted. The primary discussion herein focuses on development of secondary flow in the S-duct with and without VGs, pressure recovery and distortion at the exit are also discussed. Full three-dimensional Navier-Stokes equations are solved using finite volume method and $k-\varepsilon$ turbulence model is employed. In order to validate the credibility of the numerical methods, predicted results of surface pressure are compared with flight test for the S-duct inlet without VGs, and it shows fairly good agreement. The result shows that VGs alter the flow characteristics in the S-duct and are effective in reducing distortion and ineffective in improving pressure recovery.

  • PDF

A Study on the Field Test and Simulation of Active Solar System for Residential House (설비형 태양열 주택 실증시험 및 시뮬레이션 연구)

  • Baeck, N.C.;Yu, J.Y.;Yoon, E.S.;Lee, D.W.;Joo, M.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.93-101
    • /
    • 2001
  • The solar space and water heating system for residential house was analyzed by both experiment and computer simulation. Computer simulation program is developed using TRNSYS 14.2 verified by experimental result. The Parametric study of this solar system was carried out using this computer simulation program. On-OFF control strategy, collector area and storage tank volume as a parameters were considered in this study.

  • PDF

Improved Coded Mark Inversion for the Passive Radio Frequency Transmission System of the Electronic Time Fuze

  • Xiong, Dong;Zeng, Xiaoping;Zhao, Xiaogang
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.348-350
    • /
    • 2009
  • To fit the limited volume and power consumption of the passive radio frequency transmission system of the electronic time fuze, an improved coded mark inversion (CMI) is proposed in this letter. From the performance analysis, the energy transmission efficiency of this encoding method is at least 50% higher than that of CMI and NRZ. Finally, the experiment results show that by adopting this improved CMI, the change of DC voltage through magnetic coupling is lower than 0.2 V when the accuracy of data transmission is above 99.5%.

  • PDF

Maximum Power Tracking Control of Photo-voltaic using the Two Phase with Combined for Step-up Chopper (2상 2중 승압형 쵸퍼에 의한 태양전지의 최대출력추적제어)

  • Oh, Dong-Seob;Park, Youn-Seok;Lee, Seung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.3-6
    • /
    • 2001
  • This paper is shows the configuration of the maximum power tracking control of Photo-voltaic and battery charge system. Up to now, the chopper system had the problem which a battery become a short life by reason of discontinuity of output current and its energy reduce. But in this paper, We propose the chopper system which maintain the successive output current and at the same time, control the maximum output location by change time-ratio using tracking of energy variation that occur because of the varied volume of insolation per a day and temperature.

  • PDF

The development of a fuel lifecycle reactivity control strategy for a generic micro high temperature reactor

  • Seddon Atkinson;Takeshi Aoki
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.785-792
    • /
    • 2024
  • This article provides an overview of the design methodology used to develop a conceptual set of reactivity control mechanism of a micro reactor based on the U-Battery. The U-Battery is based on remote deployment and therefore it is favourable to provide a long fuel lifecycle. This is achieved by implementing a high fissile loading content, which proves challenging when considering reactivity control methods. This article follows the design methodology used to overcome these issues, with an emphasis on a new concept of a moveable moderator which utilises the size of the U-Battery as a small reduction in moderation provides a significant reduction in reactivity. The latest work on this project sees the moveable moderator investigated during a depressurised loss of forced coolant accident, where a reduction of moderator volume increases the maximum fuel temperature experienced. The overall conclusion is that the maximum fuel temperature is not significantly increased (4 K) due to the central reflector region relatively lower volumetric heat capacity compared to that of whole core. However, a small temperature increase is observed immediately after the transient due to the central reflector removal because it reaches energy equilibrium with the fuel region faster.

Transient Characteristics and Physical Constraints of Grid-Tied Virtual Synchronous Machines

  • Yuan, Chang;Liu, Chang;Yang, Dan;Zhou, Ruibing;Tang, Niang
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1111-1126
    • /
    • 2018
  • In modern power systems, distributed generators (DGs) result in high stress on system frequency stability. Apart from the intermittent nature of DGs, most DGs do not contribute inertia or damping to systems. As a result, a new control method referred to as a virtual synchronous machine (VSM) has been proposed, which brought new characteristics to inverters such as synchronous machines (SM). DGs employing an energy storage system (ESS) provide inertia and damping through VSM control. Meanwhile, energy storage presents some physical constraints in the VSM implementation level. In this paper, a VSM mathematical model is built and analyzed. The dynamic responses of the output active power are presented when a step change in the frequency occurs. The influences of the inertia constant, damping factor and operating point on the ESS volume margins are investigated. In addition, physical constraints are proposed based on these analyses. The proposed physical constraints are simulated using PSCAD/EMTDC software and tested through RTDS experiment. Both simulation and RTDS test results verify the analysis.

A Bridge Transported Bilateral Force-Reflecting Servo-Manipulator for Maintenance of Nuclear Pyroprocessing Equipment

  • Park, B.S.;Jin, J.H.;Ko, B.S.;Lee, J.K.;Yoon, J.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2226-2230
    • /
    • 2005
  • The Advanced Spent Fuel Conditioning Process (ACP), which is a pre-disposal treatment process for spent fuel is being developed at the Korea Atomic Energy Research Institute (KAERI). The ACP equipment is operated in an intense radiation field as well as in a high temperature. Thus, the equipment is designed in consideration of the remote handling and maintenance. This paper describes a Bridge Transported Bilateral Force-Reflecting Servo-Manipulator (BTSM) system, which is being developed to overcome the limitation of access that is a drawback of the mechanical Master-Slave Manipulators (MSMs), which are mounted on the ACP hot cell wall for the operation and the maintenance of the ACP equipment. The BTSM system was manufactured and temporally installed at the mockup to test its performance. The manufactured BTSM system will be installed at the ACP hot cell on June 2005 after the accomplishment of the performance test. The BTSM system consists of four components: a transporter with a telescoping tubeset, a slave manipulator, a master manipulator, and a remote control system. This system will highly increase the volume of coverage for the operation and maintenance of the ACP equipment.

  • PDF

Measurement of the Elemental Composition in Airborne Particulate Matter Using Instrumental Neutron Activation Analys

  • Chung, Yong-Sam;Lim, Jong-Myoung;Moon, Jong-Hwa;Kim, Sun-Ha;Cho, Hyun-Je;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.450-459
    • /
    • 2004
  • For the evaluation of emission sources by air sampling, airborne particulate matter for fine (<2.5 ${\mu}m2$ EAD : $PM_{2.5}$) and coarse partical (2.5-10 ${\mu}m2$ EAD : $PM_{2.5-10}$ fractions were collected using a Gent stacked filter unit low volume sampler and two types of polycarbonate filters. Air samples were collected twice monthly at two regions in and around Daejeon city in the Republic of Korea from January to December 2002. Monthly mass concentration of $PM_{2.5}$ and $PM_{2.5-10}$ were measured and the concentrations of 10 marker elements (Al, Sc, Ti ; Na, Cl ; As, V. Sb, Br, Se) were determined by an instrumental neutron activation analysis. Analytical quality control was corried out using certified reference materials. Enrichment factors were also calculated from the monitoring data to classify the anthropogenic and crustal origins.

Energy transport analysis for the Taylor-Proudman column in la rapidly-rotating compressible fluid (압축성 회전 유동에서의 Taylor-Proudman 기둥의 에너지 전달에 관한 해석)

  • Park Jun Sang;Hyun Jae Min
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.329-332
    • /
    • 2002
  • A theoretical study is made of the steady flow of a compressible fluid in a rapidly rotating finite cylinder. Flow is generated by imposing mechanical and/or thermal disturbances at the rotating endwall disks. Both the Ekman and Rossby numbers are small. A detailed consideration is given to the energy budget for a control volume in the Ekman boundary layer. A combination of physical variables, which is termed the energy contents, consisting of temperature and modified angular momentum, emerges to be relevant. The distinguishing features of a compressible fluid, in contrast to those of an incompressible fluid, are noted. For the Taylor-Proudman column to be sustained, in the interior, it is shown that the net energy transport between the solid disk wall and the interior fluid should vanish. Physical rationalizations are facilitated by resorting to the concept of the afore-stated energy content.

  • PDF