• 제목/요약/키워드: Control Rooms

검색결과 263건 처리시간 0.027초

바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석 (Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies)

  • 이준우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

Intelligent Software System for the Advanced Control Room of a Nuclear Power Plant

  • Chang, Soon-Heung;Park, Seong-Soo;Park, Jin-Kyun;Gyunyoung Heo;Kim, Han-Gon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.443-448
    • /
    • 1997
  • The intelligent software system for nuclear power plants (NPPs) has been conceptually designed in this study. Its design goals are to operate NPPs in n improved manner and to support operators' cognitive tasks. It consists of six major modules such as "Information Processing," "Alarm Processing," "Procedure Tracking," "Performance Diagnosis," and "Event Diagnosis" modules for operators and "Malfunction Diagnosis" module for maintenance personnel. Most of the modules have been developed for several years and the others are under development. After the completion of development, they will be combined into one system that would be main parts of advanced control rooms in NPPs. that would be main parts of advanced control rooms in NPPs.

  • PDF

반도체 클린룸용 배기 열회수식 에어와셔의 에너지 소비량 성능평가 실험 (An Experiment on Performance Evaluation of Energy Consumption of an Exhaust Air Heat Recovery Type Air Washer for Semiconductor Manufacturing Clean Rooms)

  • 송근수;유경훈;신대건;손승우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.844-849
    • /
    • 2008
  • In recent semiconductor manufacturing clean rooms, in order to improve clean room air quality, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. From the energy saving point of view, heat recovery is useful for the reduction of air conditioning energy consumption for clean room. Therefore it is desirable to recover heat from the exhaust air and use it to reheat the outdoor air. However, so far there have not been sufficient studies of analyzing the comparison of the amounts of energy consumption and saving. In the present study, an experiment was conducted to investigate the energy consumption and heat recovery of a fin-coil type air washer system for semiconductor manufacturing clean rooms.

  • PDF

전남 지방 전통주택의 음향특성에 관한 실험적 연구 (An Experimental Study on the Acoustic Characteristic of Korean Traditional Houses in Chonnam Province)

  • 이태강;김형렬;김항;최은석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.686-689
    • /
    • 2005
  • This study aims to analyzed the acoustics characteristics of Korean Traditional Houses in Chonnam Province varied with lay out and floor plane to reflect the way of control for environmental condition. These houses are surveyed the reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen. As a result, the reverberation time of traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building.

  • PDF

반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가 (An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms)

  • 여국현;박상태;유경훈;손승우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

호텔 객실판매 예측에 관한 실증적 연구 - 서울지역 특급호텔을 중심으로 - (Empirical Study on the Forecasting of the Hotel Room Sales)

  • 한승엽
    • 산학경영연구
    • /
    • 제4권
    • /
    • pp.281-295
    • /
    • 1991
  • Nothing is more incorrect than forecasting. Nevertheless, forecasting is one of the most important business activities for the effective management. There has been rapid changes of the growth rate in every respect of the Korean hospitaity industry, especially the hotel industry, before and after the 88 Olympic Games. Therefore, the hoteliers shall be in need of more-than-ever accourate demand forecasting for the more systematic management and control. Under the above circumstances, this study suggested the best forecasting technique and method for the better sales and operations of the hotel rooms. The number of rooms sold is selected as a dependent variable of this study which is regarded as the best representative factor of measuring the growth rate of the rooms division performance of the hotels. The first step was to select the most verifiable independent variable diferently from the other countries or other areas of Korea. As a result, the number of foreign visitors was chosen. Empirical research, i.e. correlation and multiple regression analysis, shows that this independent variable has a strong relationship with the dependent variable told above. The second procedure was to estimate the number of rooms will be sold in 1991 on the basis of the formula calculated through the multiple regression analysis. Time series technique was conducted using the data of the number of foreign visitors by purpose of travel from 1987 to 1990. For the more correct forecasting, however, it would be desirable to adopt the data from 1989 considering the product or the industry life cycle. In addition, deeper analysis for the monthly or seasonal forecasting method is needed as a future research.

  • PDF

응급실 간호사의 감염관리 수행도 및 관련 요인 (Compliance with Nosocomial Infection Control and Related Factors among Emergency Room Nurses)

  • 박상연;신동수;이현구;김희숙
    • 기본간호학회지
    • /
    • 제15권2호
    • /
    • pp.153-160
    • /
    • 2008
  • Purpose: This study was done to examine the level of compliance and the relation of related factors of nosocomial infection control among nurses in emergency rooms. The data will provide fundamental information for developing programs for nosocomial infection control in the emergency room. Method: Study participants were 183 nurses working in emergency rooms in general hospitals that had more than 500 beds and were located in Daegu, Daejeun, and Pusan. The survey was carried out from March 7 to March 26, 2006 and a structured questionnaire was used. Descriptive statistics, t-test, ANOVA and Sheffe test with SPSS 14.0 were used to analyze the data. Results: The average level for practice of infection control was relatively low Levels of compliance were high when the participants had: 1) regular conferences for nosocomial infection control, 2) positive perception of protection devices, 3) knowledge of whom to report and experiences of reporting needle stick injuries, 4) hospital guidelines for infection control and 5) enough equipment supplies from the hospital. Conclusion: Nosocomial infection control among emergency room nurses could be improved via personal, psychosocial, and organizational factors and related education.

  • PDF

의과대학의 임상실습공간에 관한 건축계획 연구 (A Study on the Architectural Planning of Clinical Practice Spaces at the College of Medicine)

  • 최광석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제27권4호
    • /
    • pp.7-14
    • /
    • 2021
  • Purpose: This study summarized architectural planning data for clinical practice spaces for CPX/OSCE and Simulation spaces, through analysis of domestic and foreign literature and a survey of domestic colleges of medicine. Methods: This study analyzed the architectural planning elements of the clinical practice spaces of the college of medicine, through a literature review on the clinical practice space and the survey of four recently established colleges of medicine. Results: ① It is desirable to plan the floor plan type for Simulation and CPX/OSCE spaces as a corridor-separated type that separates the circulations between students and staff (faculty). ② The simulation area arranges their practice rooms around the control space where the circulation of the staff is made. Conversely, it is desirable to arrange the CPX/OSCE rooms around the test waiting room where students enter. ③ It is desirable to separate access to the staff and students to allow student control, and to install various support spaces facing the staff corridor to secure the movement of equipment and the flow of evaluators. ④ In the simulation area, the equipment stored in the storage must be set in each room before the practice according to the setting of delivery or surgery like, and the equipment that has been removed must be back, so the circulation is short and does not intersect with the student circulations. ⑤ Debriefing rooms, seminar rooms, etc. are arranged in the staff area for review and discussion of clinical situations where practice and evaluation have been completed. Implications: It is important to configure an appropriate movement system and spatial zoning for each space for simulation and CPX/OSCE.

의료기관의 결핵감염관리 현황 (Status of Tuberculosis Infection Control in Hospitals)

  • 이나영;김경희;강희선
    • 기본간호학회지
    • /
    • 제20권4호
    • /
    • pp.359-371
    • /
    • 2013
  • Purpose: The purpose of this study was to determine the status of tuberculosis (TB) infection control in hospitals. Method: This study was a cross-sectional descriptive study in which self-administered questionnaires were used to survey 77 hospitals. Data were collected from August 12 to September 15, 2012. Results: Only 27 institutions (35.1%) were monitoring patients infected with or suspected of having TB. Most hospitals were conducting TB prevention education for patients' family and employees, and TB screening for employees along with follow-up examinations. However, private negative pressure rooms were more often available in wards and intensive care units than in outpatient departments, and in institutions with over 700 beds located in Seoul or GyeongGi Province. Most hospitals ensured that masks were placed on infected patients while transporting them. In addition, efforts to control TB infection such as placing respiratory etiquette posters in outpatient departments and airborne infection signs on the doors in the wards were also well established in most institutions. Conclusion: More efforts are needed to improve the status of TB infection control to ensure quality care, especially in terms of monitoring patients with TB infections and making private negative pressure rooms available in outpatient departments.