• Title/Summary/Keyword: Control Points Management

Search Result 401, Processing Time 0.027 seconds

Research on Standardization for Survey Control Points (측량기준점 표준화 방안 연구)

  • Lee, Hyun Jik
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.79-88
    • /
    • 2015
  • In any production and construction of geospatial information covering surveying, survey control point is a vital geospatial information. Survey control points in South Korea are currently classified as following: national control points, public control points, and cadastral control points. Each of these different categories of survey control points act as a basis and sets perimeters for the production, management and operation of subjects within the category. Universal standard, the unified format between different survey control points, also, are not yet defined, causing difference in basic information provided by altering categories and disturbance in connecting, managing, utilizing and operating survey control points. Establishment of a standard regarding survey control points, is therefore required for the efficacy of their utilization. This study, to solve such inadequacies, selects management items for creation of standardized survey control point, by investigating domestically and internationally the status of operating survey control points, determining data model for management, establishing TTA and agency standards, and establishing of activation methodology for survey control point standards.

Infection control by type of dental institution (치과의료기관 유형별 감염관리 이행실태)

  • Lee, Ye-Rin;Han, Gyeong-Soon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.6
    • /
    • pp.875-888
    • /
    • 2020
  • Objectives: The purpose of this study was to investigate the infection control system and actual conditions according to the type of dental medical institution. Methods: From April 1st to May 10th, 2020, dental institutions were recruited through stratified random sampling. Each item constituting the infection control system by dental institution type was analyzed using the chi-square test and fisher's exact test. Results: The infection control system and operation level of each dental institution type was 89.0 points for university-general hospitals, 75.6 points for dental hospitals, and 34.4 points for dental clinics. The environment management levels were 76.1, 72.5, 73.0, and 74.0 points for university-general hospitals, similar to 77.2, 75.1, 71.0, and 73.8 points for dental hospitals, while dental clinics had 61.1, 40.0, 37.0, and 45.6 points. Prevention and management of staff infection exposure, wearing personal protective equipment, and hand hygiene levels were 90.7, 75.5, 88.5 points for university-general hospitals, 79.8, 79.5, 80.4 points for dental hospitals, and 50.2, 88.0, 61.5 points for dental clinics, respectively. Conclusions: Efforts are required to bring about improvement in the areas of insufficient infection control in order to raise the overall infection control levels, especially the management of dental clinics is urgently needed.

A Study on the Improvement of Management for Survey Control Points in Seoul City (서울시 측량 기준점 관리 개선방안에 관한 연구)

  • Lee, Woo Sik;Lee, Eun Young
    • Spatial Information Research
    • /
    • v.20 no.5
    • /
    • pp.111-118
    • /
    • 2012
  • Survey control points managed by national and local governments are associated with civilian's property and they are very important national facilities. Despite the importance of surveying results, Database and mark of survey control points, there are many problems noticed of the management aspects such as manpower, systems, and related law. Currently, each local government has built and operated Geographic Information System(GIS) independently by National Geographic Information Systems(NGIS) results. but it is still difficult to have the integration, linking and utilizing. Therefore, In this study proposed the functional improvement of GIS based control points integrated system for providing information and management and the establishment of first-payment system due to the moving of control points. Through this studies will be able to solve the problem of recovery charges according to unknown contractor and establish the basis of manager and user-centric one-stop integration system.

An Economic Design of the EWMA Control Charts with Variable Sampling Interval (VSI EWIMA 관리도의 경제적 설계)

  • 송서일;정혜진
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.4
    • /
    • pp.1-14
    • /
    • 2002
  • Traditional SPC techniques are looking out variation of process by fixed sampling interval and fixed sample size about every hour, the process of in-control or out-of-control couldn't be detected actually when the sample points are plotted near control limits, and it takes no notice of expense concerned with such sample points. In this paper, to overcome that, consider VSI(variable sampling interval) EWMA control charts which VSI method is applied. The VSI control charts use a short sampling internal if previous sample points are plotted near control limits, then the process has high probability of out-of-control. But it uses a long sampling interval if they are plotted near centerline of the control chart, since process has high possibility of in-control. And then a comparison and analysis between FSI(fixed sampling interval) and VSI EWMA in the statistical aspect and economic aspect is studied. Finally, we show that VSI EWMA control chart is more efficient than FSI EWMA control chart in the both aspects.

A Implementation of Surveyed Control Point Management System for National Land based on RFID (RFID 기반의 국토측량 기준점 관리 시스템 구현)

  • Cho, Jong Sik;Kim, Young Gon;Lee, Young Woong;Ju, Jong Gil;Seo, Ho Suk;Sim, Choon Bo;Sin, Chang Sun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • In this paper, we propose a management system for positioning and indicating the surveyed control point using RFID and UMPC. This system is composed of digital control point, management system and application. The digital control point transmits information of the surveyed control point and the management system receives the data from the digital control points and manages the scattered digital control points. The system offers three services for managing the surveyed control point. The first service is control point monitoring service for identifying the change of location, locating the missing control point and the second service is control point search service notifying selected control point to user, and the third service is control point land management service for editing the control point information in the land. Therefore, this system makes it easy for administrators to access the control point information of the scattered surveyed control point through the country and enhances the managing efficiency.

Studies on the HACCP Model of Steak-Set Menu in Hotel (HACCP 모델 적용시 호텔 .레스토랑의 세트 메뉴 중 스테이크에 관한 연구)

  • 양신철
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.12 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • This study was focused on the sanitary analysis of hazard factors and the establishment of critical control points on steak-set menu In hotel by the documents and microbiological investigation. The hazard factors of shrimp cocktail were microbial contamination, residual pesticides, unsuitable healing and cross contamination. The hazard factors of potato soap were residual pesticides, microorganisms contamination, unsuitable heating and solanine in potato. The hazard factors of simple salad were microorganisms contamination, unsuitable heating and cross contamination by inappropriate package. The hazard factors of steal were residual antimicrobial drugs, microorganisms contamination, unsuitable heating and cross contamination. The critical control points of shrimp cocktail were temperature control , number of washing and center temperature control of heating step. The critical control points of potato soup were stock temperature control , number of washing and center temperature control of Heating step. The critical control points of simple salad were number of washing and dryness of utensil. The critical control points of steak were stock temperature control , number of washing, center temperature and time control of heating step.

  • PDF

Knowledge and Performance on Infection Control among Caregivers in Home Care Services (가정간호 주돌봄 제공자의 감염관리에 대한 지식 및 수행도)

  • Shon, Soonyoung
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.21 no.1
    • /
    • pp.69-78
    • /
    • 2014
  • Purpose: This study aimed at providing guidelines and educational manuals on infection control for the home care environment, by assessing the knowledge and performance among the caregivers in home care. Methods: Data were collected from January to March 2013. Participants were 172 caregivers who were registered in the home nursing center of university hospitals. Results: The total score on the level of knowledge of infection control was 13.28 points (${\pm}3.49$) out of 20 points. Secondly, 4.15 points were obtained for individual hygiene management, 4.14 points for hand wash, and 3.86 points for environment management. Lastly, the relationship between the knowledge and performance of infection control showed a significant positive correlation (r=0.37, p<.001). Conclusion: In many instances, the caregivers in the home environment provide nursing care for patients with chronic diseases and make use of various invasive devices. This study recommends the development of a manual or educational guidelines on infection control that can be used by caregivers at the home.

The Development and Effect of NCS-based Cooking Practice Teaching Method by Using Bloom's Mastery Learning Model (Bloom의 완전학습모델을 활용한 NCS 기반 조리 실무 교수·학습 개발 및 효과)

  • Oh, Wang-Kyu
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.5
    • /
    • pp.1058-1067
    • /
    • 2017
  • The purpose of this study was to develop the NCS-based cooking practice education method by using the full learning model and to confirm its effect. The study design was a pre-post test of the non-equality control group. The subjects of this study included 28 students in the experimental group and 27 students in the control group. The experimental group participated in the NCS-based cooking practice training using the complete learning model, and the control group received only cooking practice training based on the full learning model. The data were collected during the second semester of 2016 and analyzed by SPSS WIN 23.0. The results of this study were as follows: First, homogeneity test showed that pre - homogeneity such as general characteristics, cooking ability, and knowledge of cooking theory were achieved (p>0.05). Second, the experimental group recognized that its cooking ability was high. With respect to the ability to cook food, the ability to cook, and the ability to prepare food ingredients (p<0.01), personal hygiene management, cooking hygiene management, and cooking safety management abilities were not significant. The mean value the experimental group was high. Third, the final theoretical knowledge score was not significant. The average score in the experimental group (69 points) was 5 points higher than that in the control group (64 points). This was about two times higher than the score of 37 points in the first stage preliminary survey. Finally, the final performance score was significant (p<0.05), and the score in the experimental group (89 points) was 5 points higher than that in the control group (84 points). Therefore, the NCS-based cooking education method is confirmed to be an effective method, especially for improvement of the practical ability, improvement of theoretical knowledge, and achievement of perfect learning standards.

An Application for Management of National Geodetic Control Points on the Web 2.0 (Web 2.0 기반 국가기준점 어플리케이션 설계)

  • Kim, Tae-Woo;Kim, Jyung-Wuk;Suh, Yong-Cheol
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.3
    • /
    • pp.79-84
    • /
    • 2009
  • As a surveying standard of a nation, the Korean geodetic control points such as triangulation points and benchmarks require continuous and effective management toward a spatially enabled society. As the developments of information technologies, use of mobile devices like PDA (personal digital assistant) has been increasing and the Web 2.0 environment became an important part of GIS. In this context, the management systems for national geodetic control points should be upgraded in accordance with the current trend, particularly for more interactive user-interface on the Web 2.0. This paper describes the framework design and prototype implementation of a Web 2.0 GIS application for the management of Korean geodetic control points. Our system enables a real-time update of the control point information and provides aerial photos on vector maps using Ajax(Asynchronous JavaScript and XML) techniques.

  • PDF

Development of the Integrated Management System of the Control Points (기준점 통합관리시스템 개발)

  • Lim, In-Seop;Lee, Jae-Kee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.4 s.31
    • /
    • pp.45-51
    • /
    • 2004
  • Control stations managed by national and local governmes are associated with other survey work and constructing geography information and they are important assets in the national level as the positional standard of the country. Since these control points are managed as some type of register and the control points could not be easily updated due to the loss of control stations from construction work or urban development. Therefore, the users could not understand the present situation of the changed control stations. In this background, the aim of this study was to develop control station management system which the managers can use to efficiently maintain control points and to support the usage of the survey control points. For developing this system, we have designed input, update, network, analysis and statistic functions, and have constructed the system using Mapobject as main engine with other languages such as Visual C++ and Visual Basic. The graphic data used in this system are 1/5,000 digital map and digital cadastral map, and the attribute data of each control station are point name, map tile name, longitude and latitude coordinates, TM coordinates, surveying data with the format of year-month-day and control situation photos and so on. In the result of constructing this control station management system, we could achieve integrated management of graphic, attribute and positioning information of each control station.

  • PDF