• Title/Summary/Keyword: Control Parameter

Search Result 4,554, Processing Time 0.037 seconds

Optimal Condition of TOC Removal Parameter for Sewage Effluent using Electrolysis Process (하수방류수 내 TOC 제거를 위한 전기분해공정의 최적 조건)

  • An, Sang-Woo;Jung, Hyuk-Sang;Lee, Hui-Kyung;Ko, Jun-Geol;Myoung, Dae-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • As the Enforcement Ordinance of Environmental Policy Act was revised in 2013, Total Organic Carbon (TOC) was added as an indicative parameter for organic matter in Water and Aquatic Ecosystem Environmental Criteria. Under these imminent circumstances, a regulatory standard is needed to achieve the proposed TOC limitation control water quality from the STP (Sewage Treatment Plant). In this study, a electrolysis utilizing the electrochemical reaction was investigated in lab-scale experiments for the treatment of TOC in sewage effluent. TOC reduction by a electrolysis was investigated response surface methodology using the Box-Begnken methods were applied to the experimental results. A central composite design was used to investigate the effects of the independent variables of electrode space ($x_1$), current density ($x_2$) and electrolyte concentration ($x_3$) on the dependent variables removal efficiency of TOC (y). The optimal conditions for electrolysis were determined: electrode space, current density and electrolyte concentration were 50 mm, $10.3mA/cm^2$ and 0.1M, respectively. Statistical results showed the order of significance of the independent variables to be electrode space > current density > electrolyte concentration.

Determination and Evaluation of Optimal Parameters in Storage Function Method using SCE-UA (SCE-UA를 이용한 저류함수모형 최적 매개변수 선정 및 평가)

  • Chung, Gunhui;Park, Hee-Seong;Sung, Ji Youn;Kim, Hyeon-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.11
    • /
    • pp.1169-1186
    • /
    • 2012
  • Storage function method has been used for flood forecasting in the major rivers in Korea, however, the researches on the relationship between the parameters and runoff characteristics was not sufficient. In addition, there has been a controversy about the optimized parameters without the consideration of the physical characteristics of the basin. Therefore, in this study, the SCE-UA method is used to optimize the parameters and the proposed method was applied with two stage optimization in the Jeongseon and Yeongwol watersheds located in the most upstream in the South Han river. The contour map was developed to investigate parameters and the error surface calculated from the runoff. The proposed parameters is to provide a range of the possible parameter set in a watershed, rather than a specific value. However, the applicability is examined using the average value of the proposed ranged parameters. In this study, the criticism about the optimization technique to find an optimal value having no physical meaning on a watershed is tried to avoid. The objective of this study is to provide a range of parameters for the flood forecasting model and the intuition about the behavior of the parameters, so the efficiency of flood forecasting is increased.

Analytical Properties of Electron Spin Resonance after Irradiation of Seasonings with Different Radiation Sources (조미료의 방사선 조사선원에 따른 전자스핀공명 분석 특성)

  • Ahn, Jae-Jun;Kim, Gui-Ran;Jin, Qiong-Wen;Kwon, Joong-Ho
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.385-391
    • /
    • 2009
  • Analytical electron spin resonance (ESR) parameters were investigated in irradiated seasonings after exposure to different radiation sources. Two commercial seasonings (SS-1 and SS-2) were irradiated with 0.20 kGy under ambient conditions using a $^{60}Co$ gamma-ray irradiator or an electron beam accelerator. Crystalline sugar-induced multi-component signals with g-values of 2.031, 2.021, 2.017, 2.009, 2.002, 1.990, and 1.980 were observed in both irradiated samples, whereas singlet signals were detected in non-irradiated materials, thereby distinguishing irradiated from control samples. Under the same analytical conditions, the ESR signal intensity of electron beam-irradiated samples was greater than that of gamma-irradiated materials. Determination coefficients (R2 values) between irradiation doses and corresponding ESR responses were 0.9916-0.9973 for all samples, and the magnetic field of specified g-values for irradiated samples remained constant. The predominant ESR signals of g2 (2.021), g4 (2.009), g5 (2.002), and g6 (1.990) showed high correlations with the corresponding irradiation doses (R2=0.8243 - 0.9929).

Effect of Previous Gastrectomy on the Performance of Postoperative Colonoscopy

  • Kim, Sunghwan;Choi, Jeongmin;Kim, Tae Han;Kong, Seong-Ho;Suh, Yun-Suhk;Im, Jong Pil;Lee, Hyuk-Joon;Kim, Sang Gyun;Jeong, Seung-Yong;Kim, Joo Sung;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.16 no.3
    • /
    • pp.167-176
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the effect of a prior gastrectomy on the difficulty of subsequent colonoscopy, and to identify the surgical factors related to difficult colonoscopies. Materials and Methods: Patients with a prior gastrectomy who had undergone a colonoscopy between 2011 and 2014 (n=482) were matched (1:6) to patients with no history of gastrectomy (n=2,892). Cecal insertion time, intubation failure, and bowel clearance score were compared between the gastrectomy and control groups, as was a newly generated comprehensive parameter for a difficult/incomplete colonoscopy (cecal intubation failure, cecal insertion time >12.9 minutes, or very poor bowel preparation scale). Surgical factors including surgical approach, extent of gastrectomy, extent of lymph node dissection, and reconstruction type, were analyzed to identify risk factors for colonoscopy performance. Results: A history of gastrectomy was associated with prolonged cecal insertion time ($8.7{\pm}6.4$ vs. $9.7{\pm}6.5$ minutes; P=0.002), an increased intubation failure rate (0.1% vs. 1.9%; P<0.001), and a poor bowel preparation rate (24.7 vs. 29.0; P=0.047). Age and total gastrectomy (vs. partial gastrectomy) were found to be independent risk factors for increased insertion time, which slowly increased throughout the postoperative duration (0.35 min/yr). Total gastrectomy was the only independent risk factor for the comprehensive parameter of difficult/incomplete colonoscopy. Conclusions: History of gastrectomy is related to difficult/incomplete colonoscopy performance, especially in cases of total gastrectomy. In any case, it may be that a pre-operative colonoscopy is desirable in selected patients scheduled for gastrectomy; however, it should be performed by an expert endoscopist each time.

Temperature Dependence on Dry Etching of $ZrO_2$ Thin Films in $Cl_2/BCl_3$/Ar Inductively Coupled Plasma ($Cl_2/BCl_3$/Ar 유도 결합 플라즈마에서 온도에 따른 $ZrO_2$ 박막의 식각)

  • Yang, Xue;Kim, Dong-Pyo;Lee, Cheol-In;Um, Doo-Seung;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.145-145
    • /
    • 2008
  • High-k materials have been paid much more attention for their characteristics with high permittivity to reduce the leakage current through the scaled gate oxide. Among the high-k materials, $ZrO_2$ is one of the most attractive ones combing such favorable properties as a high dielectric constant (k= 20 ~ 25), wide band gap (5 ~ 7 eV) as well as a close thermal expansion coefficient with Si that results in good thermal stability of the $ZrO_2$/Si structure. During the etching process, plasma etching has been widely used to define fine-line patterns, selectively remove materials over topography, planarize surfaces, and trip photoresist. About the high-k materials etching, the relation between the etch characteristics of high-k dielectric materials and plasma properties is required to be studied more to match standard processing procedure with low damaged removal process. Among several etching techniques, we chose the inductively coupled plasma (ICP) for high-density plasma, easy control of ion energy and flux, low ownership and simple structure. And the $BCl_3$ was included in the gas due to the effective extraction of oxygen in the form of $BCl_xO_y$ compounds. During the etching process, the wafer surface temperature is an important parameter, until now, there is less study on temperature parameter. In this study, the etch mechanism of $ZrO_2$ thin film was investigated in function of $Cl_2$ addition to $BCl_3$/Ar gas mixture ratio, RF power and DC-bias power based on substrate temperature increased from $10^{\circ}C$ to $80^{\circ}C$. The variations of relative volume densities for the particles were measured with optical emission spectroscopy (OES). The surface imagination was measured by scanning emission spectroscope (SEM). The chemical state of film was investigated using energy dispersive X-ray (EDX).

  • PDF

Optimization of wiring process in semiconductor with 6sigma & QFD (6시그마와 QFD를 활용한 반도체용 wire공법 최적화 연구)

  • Kim, Chang-Hee;Kim, Kwang-Soo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.3
    • /
    • pp.17-25
    • /
    • 2012
  • Wire bonding process in making semiconductor needs the most precise control and Critical To Quality(CTQ). Thus, it is regarded to be the most essential step in packaging process. In this process, pure gold wire is used to connect the chip and PCB(substrate or lead frame). However, the price of gold has been skyrocketing continuously for a long period of time and is expected to further increase in the near future. This phenomenon situates us in an unfavorable condition amidst the competitive environment. To avoid this situation, many semiconductor material making companies developed new types of wires: Au.Ag wire is one material followed by many others. This study is aimed to optimize the parameter in wire bonding with the use of 6sigma and QFD(Quality Function Deployment). 6sigma process is a good means to not only solve the problem, but to increase productivity. In order to find the key factor, we focused on VOB(Voice of Business) and VOC(Voice of Customer). The main factors from VOB, VOC are called CTQ. However, there were times when these main factors were far from offering us the correct answer, thus making the situation more difficult to handle. This study shows that QFD aids in deciding which of the accurate factors to undertake. Normally QFD is used in designing and developing products. 6sigma process is held more effective when it used with QFD.

  • PDF

Usefulness Assessment of Automatic Analysis Program for Flangeless Esser PET Phantom Images (Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가)

  • NamGung, Chang-Kyeong;Nam, Ki-Pyo;Kim, Kyeong-Sik;Kim, Jeong-Seon;Lim, Ki-Cheon;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.63-66
    • /
    • 2009
  • Purpose: ACR (American College of Radiology) offers variable parameters to PET/CT quality control by using ACR Phantom. ACR Phantom was made to evaluate parameters which are uniformity, attenuation, scatter, contrast and resolution. Manual analysis method wasn't good for the use of QC because values of parameter were changed as it may user and it takes long time to analysis. Ki-Chun Lim, a nuclear scientist in AMC, developed program that automatically analysis values of parameter by using ACR Phantom to overcome above problems. In this study, we evaluated automatic analysis program's usability, through the comparing SUV of each method, reproducibility of SUV when repeated analysis and the time required. Materials and Methods: Using Flangeless Esser PET Phantom, the ideal ratio of 4 : 1 hot cylinder and BKG but it actually showed a ratio of 3.89 to 1 hot cylinder and BKG. SIEMENS Biograph True Point 40 was used in this study. We obtained images using ACR phantom at Fusion WB PET Scan condition (2 min/bed) and 120 kV, 100 mAs CT condition. Using True X method, 3 iterations, 14 subsets, Gaussian filter, FWHM 4 mm and Zoom Factor 1.0, $168{\times}168$ image size. We obtained Max. & Min. SUV and SUV Mean values at Cylinder (8, 12, 16, 25 mm, Air, Bone, Water, BKG) by automatic program and obtained SUV by manual method. After that, we compared manual and automatic method. we estimate the time required from opened the image data to final work sheet was completed. Results: Automatic program always showed same result and same the time required. At 8, 12, 16 and 25 m cylinder, manual method showed 6.69, 3.46, 2.59, 1.24 CV values. The larger cylinder size became, the smaller CV became. In manual method, bone, air, water's CV were over 9.9 except BKG (2.32). Obtained CV of Mean SUV showed BKG was low (0.85) and bone was high (7.52). The time required was 45 second, 882 second respectably. Conclusions: As a result of difference automatic method and manual method, automatic method showed always same result, manual method showed that the smaller hot cylinders became, the lager CV became. Hot cylinders mean region size, the smaller hot cylinder size becomes we had some trouble in doing ROI poison setting. And it means increase in variation of SUV. The Study showed the time required of automatic method was shorten then manual method.

  • PDF

Comparison between Cournot-Nash and Stackelberg Game in Bi-level Program (Bi-level program에서 Cournot-Nash게임과 Stackelberg게임의 비교연구)

  • Lim, Yong-Taek;Lim, Kang-Won
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.99-106
    • /
    • 2004
  • This paper presents some comparisons between Cournot-Nash and Stackelberg game in bi-level program, composed of both upper level program and lower level one. The upper level can be formulated to optimize a specific objective function, while the lower formulated to express travelers' behavior patterns corresponding to the design parameter of upper level problem. This kind of hi-level program is to determine a design parameter, which leads the road network to an optimal state. Bi-level program includes traffic signal control, traffic information provision, congestion charge and new transportation mode introduction as well as road expansion. From the view point of game theory, many existing algorithms for bi-level program such as IOA (Iterative Optimization Assignment) or IEA (Iterative Estimation Assignment) belong to Cournot-Nash game. But sensitivity-based algorithms belongs to Stackelberg one because they consider the reaction of the lower level program. These two game models would be compared by using an example network and show some results that there is no superiority between the models in deterministic case, but in stochastic case Stackelberg approach is better than that of Cournot-Nash one as we expect.

Capacity of Urban Freeway Work Zones (도시 고속도로 공사구간 용량 산정)

  • Lee, Mi Ri;Kim, Do-Gyeong;Kim, Hyo-Seung;Lee, Chungwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1123-1130
    • /
    • 2013
  • This paper aims to estimate work zone base capacity by the number of lanes for urban freeway. To do this, data were collected from the field survey and the database system maintained by traffic control center, and analyzed with four different methods such as the average maximum observation flow rate, headway, regression analysis, and parameter inspection. The work zone base capacity for urban freeway is estimated based on the average maximum observation flow rate and headway method, which are more reliable methods compared to others. The average capacity is 1,650pcphpl when the design speed is 80km/h. The capacity of four lanes one-way work zones was about 1,700pcphpl, while one of 2 lanes one-way work zones was about 1,600pcphpl. The capacity reduction rates for each are 0.15 and 0.2, respectively. The smaller the number of lane is, the more base capacity is reduced. For verification of results, we estimate the capacity by simulation analysis using PARAMICS, and compare with analytical results by a statistical method. This research can be used for efficient and systemic management of work zone in the urban freeway.

A Correction Effect of Multiaxial Lower Extremity Orthosis in Patients with Genu Valgum (다 축면 하지 보조기가 외반슬 교정에 미주는 효과)

  • Chang In-Su;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.355-372
    • /
    • 2002
  • The purpose of this study was to evaluate the effect of multiaxial lower extremity orthosis on correction of genu valgum. 20 volunteers among people visited department of Rehabilitation Medicine, chungnam national university hospital, who had been diagnosed as genu valgum without other musculoskeletal problems were included. 10 individuals(mean age: 9.gyrs) who had been taken multiaxial lower extremity orthosis at least 12month were included in experimental group and the other 10 individuals(mean age: 11.7yrs) refused taking this orthosis in the control group. We measured the Q-angle & femorotibial angle using plain roentgenogram images at visiting day and repeat same test after 1year follow up. Multiaxial lower extremity orthosis consist of proximal horizontal bar with both thigh cuff, central vertical bar and distal horizontal bar with both shoes. we narrowed inter-shoes distance from start to 6th month and inter-thigh cuff distance together with above correction for next 6month in the frontal plane and from 10th month, dorsiflexed both shoes in sagittal plane. Also, we rotate the both shoes externally and retract the proximal vertical bar every month. This orthosis have to be taken at least 4 hours during sleep. The result were as follows 1. There were no statistical significant difference in each parameter between the right and left Q-angle before multiaxial lower extremity orthosis. 2. The left Q angle reduced $-11^{\circ}$ between 1st day and after 1year follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001). 3. The right Q angle reduced $-13^{\circ}$ between 1st day and after 1year follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001). 4. There were no statistical significant difference in each parameter between the right and left femorotibial angle before multiaxial lower extremity orthosis. 5. The left femorotibial angle reduced $-10.1^{\circ}$ between 1st day and after lyear follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001). 6. The right femorotibial angle reduced $-11.2^{\circ}$ between 1st day and after 1year follow up showed statistical significant difference between multiaxial lower extremity orthosis taking group and non-taking(p<0.001).

  • PDF