• Title/Summary/Keyword: Control Parameter

Search Result 4,554, Processing Time 0.042 seconds

Effects of the Combined Stress Induced by Stocking Density and Feed Restriction on Hematological and Cytokine Parameters as Stress Indicators in Laying Hens

  • Kang, Sun-Young;Ko, Young-Hyun;Moon, Yang-Soo;Sohn, Sea-Hwan;Jang, In-Surk
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.3
    • /
    • pp.414-420
    • /
    • 2011
  • A study was conducted to investigate the effects of the combined stressor induced by high stocking density with feed restriction on immunological parameters such as leukocyte differential counts and cytokine expression in laying hens. A total of forty White Leghorn laying hens were randomly allotted into the control (12 kg of body weight/$m^2$) and the stress (44 kg of body weight/$m^2$) groups, and then birds of the stress group were given 75% of voluntary intake of the control birds for 12-d on a daily basis. There was a significant decrease in body weight without affecting the relative weights of the liver and spleen after 12-d of the combined stressor. In hematological values, no significant difference in leukocyte differential counts including heterophils (H), lymphocytes (L), monocytes and H:L ratio was observed between the two groups. In cytokines, hepatic lipopolysaccharide-induced tumor necrosis factor-${\alpha}$ (LITNF-${\alpha}$) and inducible nitric oxide synthase (iNOS) expression levels in the stress group were significantly (p<0.05) higher compared with those in the control group. However, the expression levels of interleukin (IL)-4 and IL-6 in the liver were not affected by the combined stressor. Splenic LITNF-${\alpha}$ expression in the combined stressor group was significantly (p<0.05) up-regulated compared with that in the control birds. However, the combined stressor did not affect splenic IL-4, IL-6 and iNOS expression. In conclusion, the combined stressor caused by high stocking density with feed restriction enhanced some pro-inflammatory cytokines including LITNF-${\alpha}$ and iNOS in lymphoid and non-lymphoid organs of birds, suggesting that altered cytokine expression to given stressors can be another parameter that can be used in assessing stress responses of birds.

Certification and Quality Control of the Official Test Facilities of Dioxins in Korea (국내 다이옥신 측정분석기관 지정 및 정도관리)

  • Jang, Seong-Ki;Kim, Tae-Seung;Lee, Won-Seok;Chung, Young-Hee;Choi, Doug-Il
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.675-682
    • /
    • 2000
  • The concentration of dioxins from flue gases of municipal waste incineration facilities with capacities over 50 tons/day are regulated by the guideline: $0.1ng-TEQ/Nm^3$ for new facilities, and $0.5ng-TEQ/Nm^3$ for existing facilities and it will be strengthened to $0.1ng-TEQ/Nm^3$ until 2003 year. Dioxins from these incineration facilities have to be measured more than 2 times annually by the Official Test Facilities of Dioxins. Seven institutions have been certified so far as the Official Test Facilities of Dioxins. These facilities have to be evaluated by the quality control program provided by National Institute of Environmental Research every year. We reported the results of quality control test performed in 1999. Four institutions certified in 1998 sampled flue gases at stack of M incineration facilitiy and analyzed dioxins by Official Methods of Air Pollution. The isokinetic coefficients, the parameter for evaluation of sampling ability were excellent for all four institutions. They were 100.9%, 102.4%, 102.1% and 99.2%, respectively. The criteria required are as follows; resolution over 10,000, mass calibration within ${\pm}5ppm$, ion abundance ratio within 15%, and the recovery of 50-120%. As results, those institutions also met these parameters of Official Method of Air Pollution.

  • PDF

Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가)

  • Hwang, Jun-Ho;Yang, Hyung-Jin;Choi, Ji-An;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.517-526
    • /
    • 2019
  • The purpose of this study is to find the optimal method for clinical application by analyzing image quality and radiation output according to parameter combination when using the Automatic Exposure Control (AEC). The experimental method combines 70, 81 kVp with sensitivity S200, S400, S800 and S1000 of the Automatic Exposure Control for Entrance Surface Dose (ESD), current volume, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Time-to-Radiation Dose Curve in abdomen and pelvis. And then, image quality and radiation output stability were evaluated. As a results, Entrance Surface Dose, current volume, Signal to Noise Ratio, Contrast to Noise Ratio decreased as the tube voltage and sensitivity were set higher. In addition, the higher tube voltage and sensitivity, the Time-to-Radiation Dose Curve showed a poor output stability. In conclusion, the higher the combination of tube voltage and sensitivity in the use of Automatic Exposure Control, the more problems can be seen in image quality and stability of the radiation output. Therefore, a relatively low combination of tube voltage and sensitivity showed that the image quality and radiation output stability could be optimized by minimizing the error range that would occur when the detector recognized a combination of parameters.

A Structural Model for Health Promotion and Life Satisfaction of Life in College Students in Korea (대학생들의 건강증진행위와 삶의 만족도에 대한 구조모형)

  • Hong, Youn-Lan;Yi, Ga-Eon;Park, Hyun-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.333-346
    • /
    • 2000
  • The purpose of this study was designed to test and develope the structural model that explains health promoting behaviors among college students in Korea. The hypothetical model was constructed on the Pender's Health promotion Model(l996) and the inclusion of some influential factors for life satisfaction. The conceptual framework was built around eight constructs. Exogenous variables included in the model were self-esteem, perceived health status, self-efficacy, internal locus of control, chance locus of control. powerful other locus of control. Endogenous variables were health promotion behaviors and life satisfaction. The results are as follows; 1. The overall fit of the hypothetical model to the data was moderate <$x^2$=4.18(df=11. p=0.041), GFI= 0.99, AGFI= 0.76, RMR= 0.019, CFI= 0.99, CN= 248.50> 2. Path and variable of the model were modified by considering both its theoretical implication and statistical significance of parameter estimates. Compared to the hypothetical model. the revised model has become parsimonious and had a better fit to the data expected in a chi-square value <$x^2$=8.43( df= 16, p=0.21), GFI= 0.99, AGFI= 0.92., RMR= 0.024, CFI= 0.99, CN= 312.01> 3. Some of the predictive factors. especially self efficacy. self esteem. powerful others locus of control. perceived health status revealed the direct effects on health promoting behaviors. Of these variables. self-efficacy was the most signigicant factor. These predictive variables of health promoting behaviors explained 59% of total variances in the model. 4. Health promoting behaviors, self-esteem. and perceived health status revealed direct effect on the life satisfaction. Self-efficacy was identified as an important variable that contributed indirectly to improve life satisfaction by enhancing health promoting behaviors. These predictive variables of life satisfaction explained 42% of total variances in the model. In conclusion. the derived model in this study is considered appropriate in explaining and predicting health promoting models and life satisfaction among college students in Korea and could effectively be used as a reference model for further studies by suggesting a direction in health promoting nursing practices.

  • PDF

Power Generation Cost Comparison of Nuclear and Coal Power Plants in Year 2001 under Future Korean Environmental Regulations -Sensitivity and Uncertainty Analysis- (미래의 한국의 환경규제여건에 따른 2001년도의 원자력과 석탄화력 발전단가비교 -민감도와 불확실도 분석-)

  • Lee, Byong-Whi;Oh, Sung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.18-31
    • /
    • 1989
  • To analyze the impact of air pollution control on electricity generation cost, a computer program was developed. POGEN calculates levelized discounted power generation cost including additional air pollution control cost for coal power plant. Pollution subprogram calculates total capital and variable costs using governing equations for flue gas control. The costs are used as additional input for levelized discounted power generation cost subprogram. Pollution output for Rue Gas Desulphurization direct cost was verified using published cost data of well experienced industrialized countries. The power generation costs for the year 2001 were estimated by POGEN for three different regulatory scenarios imposed on coal power plant, and by levelized discounted power generation cost subprogram for nuclear power. Because of uncertainty expected in input variables for future plants, sensitivity and uncertainty analysis were made to check the importance and uncertainty propagation of the input variables using Latin Hypercube Sampling and Multiple Least Square method. Most sensitive parameter for levelized discounted power generation cost is discount rate for both nuclear and coal. The control cost for flue gas alone reaches additional 9-11 mills/kWh with standard deviation less than 1.3 mills/kWh. This cost will be nearly 20% of power generation cost and 40% of one GW capacity coal power plant investment cost. With 90% confidence, the generation cost of nuclear power plant will be 32.6-51.9 mills/kWh, and for the coal power plant it will be 45.5-50.5 mills/kWh. Nuclear is favorable with 95% confidence under stringent future regulatory requirement in Korea.

  • PDF

Design of Processor Lever Controller for Electric Propulsion System of Naval Ship (전기추진 함정용 프로세서 레버 제어기 설계)

  • Shim, Jaesoon;Lee, Hunseok;Jung, Sung-Young;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.1
    • /
    • pp.134-145
    • /
    • 2021
  • It is common to optimize the propulsion control system through a so-called tuning process that modifies the parameter values of the propulsion control software during a ship commissioning. However, during this process, if the error of the initial setting value is large, the tuning time may take too long, or the propulsion equipment can be seriously damaged. Therefore, we conducted research on the design of a propulsion controller that applied a Processor lever controller even for inexperienced people with relatively little experience in tuning propulsion control software to be able to reduce the tuning time while protecting the propulsion system. Through simulation, by comparing the execution result of propulsion control lever commands through the PI controller without applying the Processor lever controller. We analyzed the improvement of the Overshoot and propulsion performance. The simulation results showed that the safety of the propulsion system increased because Overshoot of approximately 9.74%, which occurred when the Processor lever function was not applied.

Derivation of Nacelle Transfer Function Using LiDAR Measurement (라이다(LiDAR) 측정을 이용한 나셀전달함수의 유도)

  • Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.929-936
    • /
    • 2015
  • Nacelle anemometers are mounted on wind-turbine nacelles behind blade roots to measure the free-stream wind speed projected onto the wind turbine for control purposes. However, nacelle anemometers measure the transformed wind speed that is due to the wake effect caused by the blades' rotation and the nacelle geometry, etc. In this paper, we derive the Nacelle Transfer Function (NTF) to calibrate the nacelle wind speed to the free-stream wind speed, as required to carry out the performance test of wind turbines according to the IEC 61400-12-2 Wind-Turbine Standard. For the reference free-stream wind data, we use the Light Detection And Ranging (LiDAR) measurement at the Shinan wind power plant located on the Bigeumdo Island shoreline. To improve the simple linear regression NTF, we derive the multiple nonlinear regression NTF. The standard error of the wind speed was found to have decreased by a factor of 9.4, whereas the mean of the power-output residual distribution decreased by 6.5 when the 2-parameter NTF was used instead of the 1-parameter NTF.

A Study on the Prediction of Discharge by Estimating Optimum Parameter of Mean Velocity Equation (평균유속공식의 최적매개변수 산정에 의한 유량예측에 관한 연구)

  • Choo, Tai Ho;Chae, Soo Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5578-5586
    • /
    • 2012
  • The accurate estimation of discharge is very essential as the important factor of river design for the utilization and flood control, hydraulic construction design. The present discharge production is using the stage-discharge relationship curve in the river. The rating curve uses the method by predicting the discharge based on regression analysis using the measured stage and discharge data in a flood season. The method is comparatively convenient and has especially advantages in that it can predict the discharge having the difficulty of observation in a flood season. However, this method has basically room for improvement because the method only uses the relationship between stage and discharge, and doesn't reflect the hydraulic parameters such as hydraulic radius, energy slope, roughness, topography, etc.. Therefore, in this study, discharge was predicted using the convenient calculation method with empirical parameters of the Manning and Chezy equations, which were proposed by Choo et at (2011) in KSCE as a new methodology for estimating discharge in open channel. The proposed method can conveniently estimate empirical parameters in both of Manning and Chezy equations and the discharge is estimated in the open channels. There are proved by using data measured in meandering lab. channel and India canal and the accuracies show about determination coefficient 0.8. Accordingly, this method will be used in actual field if this study is continuously conducted.

Characteristics of Small Business Start-Up and Effect of Preparation of Small Business Start-up on Business Performance -Focusing on Mediating Effect of Self-Efficacy (소상공인 창업자특성과 창업준비과정이 창업성과에 미치는 영향에 관한 연구 : 자기효능감 매개효과를 중심으로)

  • Kang, Young-Uk;Ha, Kyu-Soo
    • Journal of Digital Convergence
    • /
    • v.10 no.9
    • /
    • pp.239-251
    • /
    • 2012
  • This study aims to seek the policies and the plans for the successful small business start-up through an exploratory study about the factors affecting the success rate of small business start-up. To measure the performance of the start-up business(sales revenue, net profit, and outcome expectancy), the characteristics of founders (experience, psychological characteristics) and the preparation of small business start-up were measured as independent variables and the self-efficacy was measured as a parameter. 427 small business owners were targeted and structured self-administered questionnaires were collected from them. For the data process, a multiple regression analysis by SPSS 18.0 was conducted. The findings demonstrated the experience in the same business, the need for achievement, the risk-taking propensity, the preparation period for business start-up had a significant effect on self-efficacy, and experience of failure and the ratio of net worth had a significant effect on sales revenue and net profit, and the locus of control had a significant effect on outcome expectancy through the self-efficacy, a parameter. It was also noted the self-efficacy of small business owners and the business performance varied depending on the characteristics of them and the preparation process of the business start-up. Based on the those findings, the theoretical and practical implications were discussed and the suggestions about the limits of the study, future policies and studies were made.

GA-Based Design of a Nonlinear PID Controller and Application to a CSTR Process (GA 기반의 비선형 PID 제어기 설계 및 CSTR 프로세스에 응용)

  • Lee, Joo-Yeon;So, Gun-Baek;Lee, Yun-Hyung;So, Myung-Ok;Jin, Gang-Gyoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.633-641
    • /
    • 2015
  • Several complex processes that are employed in industries, such as shipping, power plants, and the petrochemical industry, involve time-varying behavior as well as strong nonlinear behavior during operation. The fixed-parameter proportional-integral-derivative (PID) controllers have difficulty in dealing with control problems that occur in such processes. In this paper, we propose a method of designing a nonlinear PID controller for industrial processes that exhibit a large number of nonlinearities and time-varying behavior. The gains of the nonlinear PID controller are characterized by a simple nonlinear function of the error and/or error rate depending on the process set-point and output. We tune the user-defined parameters using a genetic algorithm by minimizing the integral of time absolute error (ITAE) index. We verify the effectiveness of the proposed method by performing a comparison of the proposed method and two other nonlinear and adaptive methods that are employed for reference tracking, disturbance-rejection performances, and robustness to parameter changes on a continuously stirred tank reactor.