• Title/Summary/Keyword: Control Object

Search Result 2,602, Processing Time 0.032 seconds

A MATHEMATICAL MODEL FOR HISTORY-BASED ACCESS CONTROL

  • Kim, Hee-Young
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.8 no.1
    • /
    • pp.11-30
    • /
    • 2004
  • Access Control is one of essential branches to provide system's security. Depending on what standards we apply, in general, there are Role-based access control, History-based access control. The first is based on subject's role, The later is based on subject's history. In fact, RBAC has been implemented, we are using it by purchasing some orders through the internet. But, HBAC is so complex that there will occur some errors on the system. This is more and more when HBAC is used with other access controls. So HBAC's formalization and model which are general enough to encompass a range of policies in using more than one access control model within a given system are important. To simplify these, we design the mathematical model called non-access structure. This Non-access structure contains to historical access list. If it is given subjects and objects, we look into subject grouping and object relation, and then we design Non-access structure. Then we can determine the permission based on history without conflict.

  • PDF

Optimum PI Controller Design for an Oil Cooler System Using GA (GA를 이용한 오일쿨러시스템의 최적 PI제어기 설계)

  • Jung, Young-Mi;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.28-34
    • /
    • 2014
  • This paper deals with optimum PI controller design using genetic algorithm to improve control performance and robustness for an oil cooler system. The optimum PI gain was found to minimize an object function, integrated absolute error, and to satisfy control design specifications such as overshoot and settling time based on practical transfer function of the oil cooler system. The control performance and robustness were investigated by comparing indicial responses and Bode diagram analysis with respect to three kinds of PI gains obtained from different gain decision manners. Moreover, the robustness against to input disturbances, sinusoidal wave form and abrupt single pulse, was evaluated. The computer simulation results showed that the suggested optimum gain can establish desirable control performance and strong robustness with easy design process.

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

Two Degree-of-Freedom $H_{\infty}$ Controller Design and Simulation For the Lateral Control of the Vehicle (차량 횡 방향 제어를 위한 2 자유도 $H_{\infty}$제어기 설계 및 모의실험)

  • 장재필;정길도
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.112-112
    • /
    • 2000
  • The aim of this paper is to design a two degree-of-freedom H$_{\infty}$ controller for lateral control of the vehicle. The object of this controller is to track the centerline of the reference lane. The controller is splited into two parts, feedback and prefilter. The feedback part is for both robust stability and disturbance attenuation, while the prefilter is for improving the robust tracking properties of closed loop system. This paper is consist of preface, background theory, dynamics of vehicle, controller design and computer simulation.ter simulation.

  • PDF

The Design of Neuro Controlled Active Suspension (신경회로망을 이용한 능동형 현가장치 제어기 설계)

  • 오정철;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.414-419
    • /
    • 1994
  • In recent years, there has been an increasing intest in control of active automotive suspension systems with a goal of improving the ride comfort and safety. Many approaches for these purposes have used linearized models of the suspension's dynamics, allowing the use of linear control theory. However, the linearized model does not well descriibe the actual system behavior which is inherently nonlinear. The object of this study is to develop a neuro controlled active suspension for the ride quality improvement. After obtaining active control law using optimal control theory, we use the artificial neural network to train the neuro controller to learn the relation of road input and control force. Form the numerical results, we found that back propagation learning does show good pattern matching and vertical acceleration of the driver's seat and sprung mass.

  • PDF

Electrostatic Suspension System of Silicon Wafer using Relay Feedback Control (릴레이 제어법을 이용한 실리콘 웨이퍼의 정전부상에 관한 연구)

  • Lee, Sang-Uk;Jeon, Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.56-64
    • /
    • 2005
  • A simple and cost-effective method for the electrostatic suspension of thin plates like silicon wafers is proposed which is based on a switched voltage control scheme. It operates according to a relay feedback control and deploys only a single high-voltage power supply that can deliver a DC voltage of positive and/or negative polarity. This method possesses the unique feature that no high-voltage amplifiers are needed which leads to a remarkable system simplification relative to conventional methods. It is shown that despite the inherent limit cycle property of the relay feedback based control, an excellent performance in vibration suppression is attained due to the presence of a relatively large squeeze film damping origination from the air between the electrodes and levitated object. Using this scheme, a 4-inch silicon wafer was levitated stably with airgap variation decreasing down to $1 {\mu}m$ at an airgap of $100{\mu}m$.

Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment (가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구)

  • Bae, Chi-Hye;Bae, Nu-Ri;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

A Study on the Control Method of Full Service Brake for Standard EMU (표준전동차의 상용전제동 제어방범에 관한 연구)

  • 이우동;변윤섭;김연수;김원경;최성규
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.103-109
    • /
    • 1999
  • The object of the study is to propose the control method of FSB(full service brake) for the standard EMU. Recently, the variable control function was applied to train by introducing the TCMS. When the vehicle in the train fails, the emergency brake of the train should be automatically operated. In case of VVVF EMU operated by the TCMS, the FSB is applied to the train for safety instead of emergency brake. When the FSB is applied to train regardless of its weight and the numbers, the train safety operation may not be obstained. Therefore, the FSB force which considers its weight and numbers should be applied to the train. This paper describes the blending brake control for standard EMU. The control algorithm of the FSB is proposed and its simulation was carried out by using MATLAB.

  • PDF

A Study on the applications of flow control methods in sewage treatment process system (하수처리 공정시스템에서 유량제어기법의 활용에 관한 연구)

  • Jeong, Seong-Yun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.597-604
    • /
    • 2016
  • This study was begun with the object of actively reflection the rapid technological advancements of the electronical control and mechanical control industries to sewage disposal methods. Or focuses on applying a flow control method that utilizes inverters and automatic valves to sewage treatment process systems. This study proposes that sewage treatment process systems architects must acquire a certain degree of technical skills in the areas of electrical and mechanical controls in order to raise the standard of completeness of sewage treatment process systems. And further emphasizes that there is required continuous research on automatics valves that are used in sewage treatment.

Industrial Robot Control using the Distributed Adaptive Control Techniques (분산 적응제어 기법을 이용한 산업용 로버트 제어)

  • 정찬수;이상철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.1
    • /
    • pp.57-64
    • /
    • 1991
  • The paper considers a distributed adaptive control technique for Industrial Robots which contribute to the factory automation. The control object is to tracking for a desired trajectories under various load conditions, rapidly against load variation. These control techniques divided whole system into subsystems which is controlled with the Nominal and Adaptational controllers. And also the asymptotic stability of these substem was proved. Simulation results shown that the proposed techniques was feasible in spite of nonlinear dynamics of robot manipulator and payload variations.

  • PDF