• Title/Summary/Keyword: Control Monitoring System

Search Result 2,994, Processing Time 0.04 seconds

Development of an OPC Client-Server Framework for Monitoring and Control Systems

  • Tan, Vu Van;Yi, Myeong-Jae
    • Journal of Information Processing Systems
    • /
    • v.7 no.2
    • /
    • pp.321-340
    • /
    • 2011
  • In this article, the current technological state of OPC (Openness, Productivity, and Collaboration; formerly "OLE for Process Control") standards and the problem statement of these OPC standards are discussed. The development of an OPC clientserver framework for monitoring and control systems is introduced by using the new OPC Unified Architecture (UA) specifications, Service Oriented Architecture (SOA), web services, XML, etc. The developed framework in turn minimizes the efforts of developers in learning new techniques and allows system architects and designers to perform dependency analysis on the development of monitoring and control applications. The potential areas of the proposed framework and the redundancy strategies to increase the efficiency and reliability of the system are also represented according to the initial results from the system that was developed by the Visual Studio 2008 and OPC UA SDK.

A Design of Infrastructure for Control/Monitoring System in the Distributed Computing Environment (분산 컴퓨팅 환경에서의 제어/감시 시스템 개발을 위한 기반 구조 설계)

  • 이원구;박재현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.547-547
    • /
    • 2000
  • Recently, due to the advance of computer, network and Internet technology, control/monitoring systems are required to process the massive data, At the same time, the software development environment uses more and more component-based methodology. This paper proposes the services for the control /monitoring domain. Especially we define domain-specific interfaces and categories to acquire compatibility between products, and implement architecture for lightweight event service. As it is very important to support compatibility between heterogeneous systems, the proposed system provides modules for the web service and communication protocols based on the XML. And as proposed architecture consists of cluster of servers and Windows 2000's NLB service, it can guarantee more stable operation,

  • PDF

The Design and Implementation of IoT based Remote Control System for Active Connected Cars (능동형 커넥티드 카를 위한 IoT기반 원격제어 시스템의 설계 및 구현)

  • Lee, Yun-Seop;Jang, Mun-Seok;Choi, Sang-Bang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.703-709
    • /
    • 2019
  • This paper proposes a monitoring and remote control system, an essential part of In Vehicle Infotainment (IVI) and Human Vehicle Interface (HVI) to provide safety and convenience to a driver. The system utilizes Bluetooth for a short range communication and utilizes WCDMA for a long range communication to enhance efficiency. In this paper, an integrated controller, which integrates a CAN communication module, a Bluetooth communication module, a WCDMA communication module, is designed to control a car. Also, a remote server for managing data is designed to provide real-time monitoring and remote control for a user via smart devices. Experiment results show that all the proposed remote control, driving log, real-time monitoring, and diagnostics functions are working properly. With the proposed system, a driver can drive safely by monitoring and inspecting a car before driving via smart devices, and control conveniently by controlling a car remotely.

The Integrated Cyber SRM(Security Risk Monitoring) System Based on the Patterns of Cyber Security Charts

  • Lee, Gang-Soo;Jung, Hyun Mi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.99-107
    • /
    • 2019
  • The "Risk management" and "Security monitoring" activities for cyber security are deeply correlated in that they prepare for future security threats and minimize security incidents. In addition, it is effective to apply a pattern model that visually demonstrates to an administrator the threat to that information asset in both the risk management and the security system areas. Validated pattern models have long-standing "control chart" models in the traditional quality control sector, but lack the use of information systems in cyber risk management and security systems. In this paper, a cyber Security Risk Monitoring (SRM) system that integrates risk management and a security system was designed. The SRM presents a strategy for applying 'security control' using the pattern of 'control charts'. The security measures were integrated with the existing set of standardized security measures, ISMS, NIST SP 800-53 and CC. Using this information, we analyzed the warning trends of the cyber crisis in Korea for four years from 2014 to 2018 and this enables us to establish more flexible security measures in the future.

Monitoring of Termite in Haeinsa Temple and Control method (해인사의 흰개미 모니터링 및 방제 방안)

  • Jeong, So-Young;Lee, Kyu-Shik;Chung, Yong-Jae
    • 보존과학연구
    • /
    • s.23
    • /
    • pp.77-93
    • /
    • 2002
  • There are several methods of pest control for the prevention of wooden cultural properties from damages caused by insects, especially termites. Those are as follows; physical control, chemical control, biological control, and integrated pest management. In Korea, we primarily use mvestigation of monitoring, fumigation, treatment of insecticidal and antiseptic chemicals, soil termiticide treatment, and termite colony elimination system. As damages by termites were detected at Eunghyanggak and Saundang of Haeinsa temple in June, 1998, we carried out monitoring with wooden device, in order to investigate damages of wooden building by termite and paths of termite invasion. According to the result of investigation of monitoring from1999 to 2002, we found that termites were inhabiting continually at forests around Haeinsa and that wooden buildings such as Saundang, Cheonghwadang were damaged by termites. So we thought that control methods such as soil termiticide treatment and termite colony elimination system would be effective. Especially, to investigate efficacy of termite colony elimination system, we carried out efficacy test of termite colony elimination system in Jongmyo during 17 months(2000.7.~2001.11.). The result of efficacy test showed that termite colony elimination system eliminated termite colonies gradually(over 12 months from installation of colony elimination system to elimination of termite colony).

  • PDF

A Study on Development of Industrial Engine Monitoring System Using Smart Phone Application (스마트폰 앱을 이용한 산업용 엔진의 모니터링 시스템 개발에 관한 연구)

  • Jeong, C.S.;Kim, Y.S.;Jeong, Y.M.;Kho, J.H.;Jeong, K.S.;Lee, H.S.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.2
    • /
    • pp.7-12
    • /
    • 2013
  • In this study, a wire/wireless communication system transmitting the operation data of engine from the ER (Engine Room) to the engine controller of ECR(Engine Control Room) has been developed through the communication of ISM(Industrial Science Medical) Band for the test operation environment improvement of medium speed engine. This wire/wireless communication system is composed of the RTU (Remote Terminal Unit) gathering and transmitting engine data as well as the MCU (Master Control Unit) receiving engine status information from the RTU to be sent to the engine controller (PLC). Through this study, a trial product of RTU and MCU has been manufactured. A test bench that has made temperature, pressure and pick-up sensor into a module for the local test of prototype was produced a test bench. In addition, at the same time save the data to a Web server and the smart phone real-time monitoring system has been developed using Wi-Fi communications. The ultimate objective of this study is to develop a wireless smart phone monitoring system of engine for the operator of engine to be able to monitor and control engine status even from the outside of engine room and control room based on this study.

The Development of Remote Corrosion Monitoring and Control System for Oil Tank by using the High Efficiency CP Rectifier (고효율 전기 방식용 정류기를 이용한 유류탱크의 원 방식 제어 시스템 개발)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.249-252
    • /
    • 2002
  • Recently, the advanced countries are using the corrosion monitoring system in a chemical plant and an oil tank in order to protect the corrosion because it leads to a big accident, pollution of soil. and lose of money Generally. the owners of the facilities adopt CP(Cathodic Protection) systems to protect the corrosion also. However, a CP system for oil tank was not considered in Korea Moreover they didn't adopted a corrosion monitoring system. In this paper, we have been developed not only the remote automatic corrosion monitoring but also the remote corrosion control system using the high efficiency CP rectifier. This results should be used to operate the CP system effectively and economically. And also it will be possible to extend the expectation life of the Oil tanks.

  • PDF

DEVELOPMENT OF A MOBULAR ENVIRONMENT MONITORING SYSTEM FOR GREENIIOUSE

  • Ryu, K.H.;Kim, H.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1081-1089
    • /
    • 1996
  • In Korean agriculture, an automatic environment control system for greenhouse is essential to save labor and to increase the quality of products. The existing environment monitoring systems have weighed on greenhouse growers and researchers because of their high cost and difficult applications. Many sensors are widely used for monitoring the greenhouse environment, but most of commercial sensors are expensive and not suitable for use in greenhouses. Thus , the development of an environment monitoring system for exclusive use in greenhouses is essential . The objective of this study was to develop modular environment monitoring systems, which are low-cost , reliable and easy -to -use. The results showed that the sensors for indoor and outdoor environments and nutrient solution had the ranges and accuracies appropriate for use in greenhouses. Also the modular environment systems developed showed a satisfactory performance in terms of stability and reliability in the measurement and acquisition of the greenhouse environment data.

  • PDF

Real-Time Remote Greenhouse Monitoring and Control Using LabView (LabView를 이용한 실시간 온실 모니터링 및 원격 제어)

  • 서정희;박흥복
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.779-787
    • /
    • 2003
  • Recently, a study on the development of remote monitoring and automation control system based on Web is spread widely. In this paper, we have expended the remote control method on the existing automation. And we proposed method to do real-time monitoring and remote control considering multimedia data processing, the expansion of TCP/IP using LabView graphical language. Also we applied the method in greenhouse environment control system. The application result was evaluated by very efficient thing to remotely monitor and control situation of greenhouse.

750kW-class DFIG Wind Turbine Monitoring System Development and Study on Scheme for Applying Standardized Communication (750kW급 DFIG 풍력 발전기 모니터링 시스템 개발 및 통신 표준화 적용 방안에 관한 연구)

  • Lee, Duck-Su;Lee, Jun-Chul;Choi, In-Sun;Choi, Young-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.327-330
    • /
    • 2008
  • This paper presents monitoring system for 750kW-class DFIG wind turbine generator system and an architecture for applying standardized communication, IEC61400-25. Monitoring and control system is consists of wind turbine PLC, Local and Remote I/O Server, HMI. and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test local and/or remote monitoring and control system and evaluate the performance of 750kW-class WTS. Finally we described the design of logical nodes and services based on IEC61400-25 and its application scheme.

  • PDF