• Title/Summary/Keyword: Control Flow

Search Result 7,455, Processing Time 0.035 seconds

Engineering Properties of CB Cut-off Walls Mixed with GGBS (고로슬래그 미분말을 혼합한 CB 차수벽의 공학적 특성)

  • Kim, Taeyeon;Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.5
    • /
    • pp.33-39
    • /
    • 2022
  • For a slag-cement-bentonite (slag-CB) cut-off wall, GGBS replaces a part of the cement mixed to build a CB cut-off wall, which is used to block the flow and leakage of pollutants or groundwater; prevent seawater infiltration; and repair or reinforcement an aged embankments. Slag-CB cut-off walls are used in various applications in different fields where groundwater control is required due to its excellent characteristics. Such properties include high strength, low permeability, high durability and chemical resistance. However, despite these advantages, slag-CB cut-off walls are not extensively studied in Korea and thus are not applied in many cases. Particularly, GGBS, which replaces cement in a mixture, has different properties depending on its country of production. Consequently, it is necessary to perform various studies on slag-CB cut-off walls that use GGBS produced in Korea in order to increase its usability. This study has evaluated the bleeding rate, setting time, strength, and permeability in relation to the cement replacement rate of GGBS produced in Korea for slag-CB cut-off walls, with the aim to increase its usability. The evaluation found that slag-CB cut-off walls, made of a mixture containing GGBS produced in Korea, have a lower bleeding rate and permeability, and higher strengththan CB cut-off walls. It was also analyzed that such improved performance is more effective with a higher cement replacement rate of GGBS.

Characterization and Phenolic Compound Analysis of Cheorwon Onion by Lime-sulphur Mixture Treatment (석회유황합제 처리에 따른 철원 양파의 생육특성 및 페놀화합물 분석)

  • Kim, Y.B.;Lee, H.J.;Kim, D.H.;Koo, H.J.;Chang, K.J.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.22 no.1
    • /
    • pp.15-25
    • /
    • 2020
  • The aim of this study was to evaluate the change of phenolic compounds after lime-sulphur mixture treatment on Cheorwon onion. Onion is a perennial plant belonging to the lily family. It is native to Persia of Southwest Asia. It is cultivated much in the temperate regions of the world. Onion is a good name for the 'Okchong' to drop blood cholesterol and cardiovascular blood flow to increase the prevention of adult diseases. Cheorwon area is inland, but it has high continental climate due to its high altitude. After the treatment with lime-sulphur mixture, the weight, width and plant height of the onion were not affected. In the phenolic compounds, caffeic acid, ferulic acid, rutin, p-coumaric acid and kaempferol except benzoic acid and quercetin were similar to or less than the control. Therefore, it was concluded that the treatment with lime-sulphur mixture had some effect on phenolic compound contents, benzoic acid and qurercetin.

Restorative effects of Rg3-enriched Korean Red Ginseng and Persicaria tinctoria extract on oxazolone-induced ulcerative colitis in mice

  • Ullah, H.M. Arif;Saba, Evelyn;Lee, Yuan Yee;Hong, Seung-Bok;Hyun, Sun-Hee;Kwak, Yi-Seong;Park, Chae-Kyu;Kim, Sung Dae;Rhee, Man Hee
    • Journal of Ginseng Research
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 2022
  • Background: Ulcerative colitis (UC) is the large intestine disease that results in chronic inflammation and ulcers in the colon. Rg3-enriched Korean Red Ginseng extract (Rg3-RGE) is known for its pharmacological activities. Persicaria tinctoria (PT) is also used in the treatment of various inflammatory diseases. The aim of this study is to investigate the attenuating effects of Rg3-RGE with PT on oxazolone (OXA)-induced UC in mice. Methods: A total of six groups of mice including control group, OXA (as model group, 1.5%) group, sulfasalazine (75 mg/kg) group, Rg3-RGE (20 mg/kg) group, PT (300 mg/kg) group, and Rg3-RGE (10 mg/kg) with PT (150 mg/kg) group. Data on the colon length, body weight, disease activity index (DAI), histological changes, nitric oxide (NO) assay, Real-time PCR of inflammatory factors, ELISA of inflammatory factors, Western blot, and flow cytometry analysis were obtained. Results: Overall, the combination treatment of Rg3-RGE and PT significantly improved the colon length and body weight and decreased the DAI in mice compared with the treatment with OXA. Additionally, the histological injury was also reduced by the combination treatment. Moreover, the NO production level and inflammatory mediators and cytokines were significantly downregulated in the Rg3-RGE with the PT group compared with the model group. Also, NLR family pyrin domain containing 3 (NLRP3) inflammasome and nuclear factor kappa B (NF-𝛋B) were suppressed in the combination treatment group compared with the OXA group. Furthermore, the number of immune cell subtypes of CD4+ T-helper cells, CD19+ B-cells, and CD4+ and CD25+ regulatory T-cells (Tregs) was improved in the Rg3-RGE with the PT group compared with the OXA group. Conclusion: Overall, the mixture of Rg3-RGE and PT is an effective therapeutic treatment for UC.

Numerical study on the foam spraying for AFDSS applicable to initial fire suppression in large underground spaces (지하대공간 초동 화재진압에 적용가능한 자율형 소화체계의 폼 분사 해석 기법 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.503-516
    • /
    • 2021
  • Autonomous fire detection and suppression system requires advanced technology for complex detection technology and injection/control technology for accurate hitting by fire location. Also, foam spraying should be included to respond to oil fires. However, when a single spray monitor is used in common, water and foam spray properties appear different, so for accurate fire suppression, research on the spray trajectory and distance will be required. In this study, experimental studies and numerical analysis studies were combined to analyze the foam spray characteristics through the spray monitor developed for the establishment of an autonomous fire extinguishing system. For flow analysis of foam injection, modeling was performed using OpenFOAM analysis software, and the commonly used foaming agent (Aqueous Film-Forming Foam) was applied for foam properties. The injection distance analysis was performed according to the injection pressure and the injection angle according to the form of the foam, and at the same time, the results were verified and presented through the injection experiment.

433 MHz Radio Frequency and 2G based Smart Irrigation Monitoring System (433 MHz 무선주파수와 2G 통신 기반의 스마트 관개 모니터링 시스템)

  • Manongi, Frank Andrew;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.136-145
    • /
    • 2020
  • Agriculture is the backbone of the economy of most developing countries. In these countries, agriculture or farming is mostly done manually with little integration of machinery, intelligent systems and data monitoring. Irrigation is an essential process that directly influences crop production. The fluctuating amount of rainfall per year has led to the adoption of irrigation systems in most farms. The absence of smart sensors, monitoring methods and control, has led to low harvests and draining water sources. In this research paper, we introduce a 433 MHz Radio Frequency and 2G based Smart Irrigation Meter System and a water prepayment system for rural areas of Tanzania with no reliable internet coverage. Specifically, Ngurudoto area in Arusha region where it will be used as a case study for data collection. The proposed system is hybrid, comprising of both weather data (evapotranspiration) and soil moisture data. The architecture of the system has on-site weather measurement controllers, soil moisture sensors buried on the ground, water flow sensors, a solenoid valve, and a prepayment system. To achieve high precision in linear and nonlinear regression and to improve classification and prediction, this work cascades a Dynamic Regression Algorithm and Naïve Bayes algorithm.

Discordance between Morphological and Molecular Variations of the Genus Macroramphosus (Macroramphosidae) from Korea (한국산 대주둥치속(대주둥치과) 어류의 형태와 분자 변이의 불일치)

  • Sohn, Min-Soo;Kim, Jin-Koo
    • Korean Journal of Ichthyology
    • /
    • v.32 no.4
    • /
    • pp.199-209
    • /
    • 2020
  • In order to clarify the taxonomic status of the Korean Macroramphosus species, which were previously confused, we investigated morphological and molecular variations of Macroramphosus (18 individuals) from Korea, and Macroramphosus (35 individuals) from Japan and Taiwan, and compared with those of M. scolopax from type locality (Mediterranean Sea). Although the Korean and Japanese specimens of Macroramphosus were clearly divided into two types in the first dorsal spine length (22.8~32.1% in A-type vs. 15.6~21.4% in B-type), distance between the first dorsal fin and second dorsal fin (6.4~9.7% vs. 8.6~13.3%), and body depth (20.0~28.0% vs. 17.3~22.6%), no genetic differences among all individuals of longspine snipefish between them were found at the specific level [d=0.0~3.3% in control region (CR); 0.0~1.3% in cytochrome b (cytb); 0.0~0.5% in cytochrome c oxidase subunit I (COI)]. Whereas, they were well distinguished in genetics (9.9~11.5% in CR; 3.8~4.6% in cytb; 1.2~3.6% in COI) from those of M. scolopax in Mediterranean Sea. It needs the scientific name of the longspine snipefish (M. scolopax) in Korea be changed as M. japonicus (and/or M. sagifue). However, our results could not find evidence of consistency between morphological and mitochondrial DNA variations which suggests that their differentiation event may occur fairly recently. Further studies using more sensitive markers such as microsatellite are needed to clarify the degree of gene flow between the two types.

Surface soil moisture memory using stored precipitation fraction in the Korean peninsula (토양 내 저장 강수율을 활용한 국내 표층 토양수분 메모리 특성에 관한 연구)

  • Kim, Kiyoung;Lee, Seulchan;Lee, Yongjun;Yeon, Minho;Lee, Giha;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.2
    • /
    • pp.111-120
    • /
    • 2022
  • The concept of soil moisture memory was used as a method for quantifying the function of soil to control water flow, which evaluates the average residence time of precipitation. In order to characterize the soil moisture memory, a new measurement index called stored precipitation fraction (Fp(f)) was used by tracking the increments in soil moisture by the precipitation event. In this study, the temporal and spatial distribution of soil moisture memory was evaluated along with the slope and soil characteristics of the surface (0~5 cm) soil by using satellite- and model-based precipitation and soil moisture in the Korean peninsula, from 2019 to 2020. The spatial deviation of the soil moisture memory was large as the stored precipitation fraction in the soil decreased preferentially along the mountain range at the beginning (after 3 hours), and the deviation decreased overall after 24 hours. The stored precipitation fraction in the soil clearly decreased as the slope increased, and the effect of drainage of water in the soil according to the composition ratio of the soil particle size was also shown. In addition, average soil moisture contributed to the increase and decrease of hydraulic conductivity, and the rate of rainfall transfer to the depths affected the stored precipitation fraction. It is expected that the results of this study will greatly contribute in clarifying the relationship between soil moisture memory and surface characteristics (slope, soil characteristics) and understanding spatio-temporal variation of soil moisture.

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

Effects of Composted Organic Fertilizer and Urea Application to Soil on the Ammonia Emissions and Fruit Quality of 'Beni Balad' Grapevine in Rain Proof Cultivation ('Beni Balad' 포도 비가림 재배에서 부숙유기질비료 및 Urea 토양 시용에 의한 암모니아 배출량 및 과실 품질)

  • Moon, Young-Ji;Moon, Byung-Woo;Kim, Min-Wook
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.313-321
    • /
    • 2021
  • BACKGROUND: Ammonia is a causative substance for the fine particulate matters (PM2.5) and generates dust through atmospheric reactions. Agricultural sector accounts for 79.3% of ammonia emissions in Korea. Urea and composted organic fertilizer (COF) are used in the soil for the purpose of supplying nutrients in grapevine orchards. This study was conducted to investigate estimates of ammonia emission and examine fruit quality from the rain proof cultivation of the 'Beni Balad', applied by urea and COF to the soil. METHODS AND RESULTS: Urea, COF1, and COF2 were applied at the rates of 119, 135, and 271 kg ha-1 respectively. Ammonia emissionwas measured using a dynamic flow-through method. CONCLUSION(S): Ammonia emissions by urea and COF treatments to 'Beni Balad' soils under rain proof cultivation were calculated to be 2.63, 12.95, 2.05, and 3.97 kg NH3-N ha-1 day-1, respectively for the control, urea, COF1, and COF2. Urea soil application increased soluble solids, firmness, and anthocyanin content in fruits at harvest, and COF1 application increased the soluble solids and anthocyanin content. For all the treatments, acidity increased in the harvested fruits.

Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2 (지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교)

  • Lee, Gunhee;Kim, Sang Bok;Park, Inyong;Hong, Kee Jung;Lee, Yeawan;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.