• 제목/요약/키워드: Control Flow

검색결과 7,435건 처리시간 0.034초

Control of Boundary Layer Flow Transition via Distributed Reduced-Order Controller

  • Lee, Keun-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1561-1575
    • /
    • 2002
  • A reduced-order linear feedback controller, which is used to control the linear disturbance in two-dimensional plane Poiseuille flow, is applied to a boundary layer flow for stability control. Using model reduction and linear-quadratic-Gaussian/loop-transfer-recovery control synthesis, a distributed controller is designed from the linearized two-dimensional Navier-Stokes equations. This reduced-order controller, requiring only the wall-shear information, is shown to effectively suppress the linear disturbance in boundary layer flow under the uncertainty of Reynolds number. The controller also suppresses the nonlinear disturbance in the boundary layer flow, which would lead to unstable flow regime without control. The flow is relaminarized in the long run. Other effects of the controller on the flow are also discussed.

밸브 형식별 유량제어범위 결정에 관한 연구 (Study of Flow Control Range according to Valve Type)

  • 박종호;박한영
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.39-47
    • /
    • 2011
  • Flow control range of valve, which is installed on pipeline, varies according to valve type, pipe diameter, pipe length, roughness, and elevation difference of both ends of pipeline. A lot of computation efforts and knowledge are needed to estimate flow control range of valve, considering above many parameters. The table of flow control range of each valve type is presented for convenience of pipeline design engineers who must make decision of valve size and type in this study. Also the reason that butterfly valve is recommended for flow control, and gate valve is forbidden is presented via quantification and figures in this study.

카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계 (Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit)

  • 이성래
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가 (A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump)

  • 정영주;조재훈;김용식;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.

제연구역의 압력변화에 따른 풍량제어 배출댐퍼 개발 (The Development of Flow Control Ventilation Damper According to the Pressure Variation of Smoke Control Room)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.69-74
    • /
    • 2018
  • 본 연구에서는 기존 제연설비의 문제점 개선 및 제연설비의 성능극대화를 위해 제연구역의 압력변화에 따라 풍량제어가 가능한 배출댐퍼를 개발하였으며, 개발 댐퍼의 효용성 검증과 상용화를 위해 성능시험을 실시하였다. 시험결과로부터 개발 배출댐퍼에 의해 급기량이 약 1 ~ 5% 정도 더 증가되는 것으로 나타났고, 제연구역에는 송풍기의 설계풍량 이상의 안정적인 풍량이 공급됨으로 풍량제어 배출댐퍼의 효용성이 입증되었다. 풍량제어 배출댐퍼의 원천기술을 확보하였다.

Operation Limit of Flow Control for a Bistable Fluidic Valve

  • Lee, Ji Ung;Hong, Ji-Seok;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.389-394
    • /
    • 2017
  • The limitation of flow control for a bistable fluidic valve has been investigated. The physical model of the fluidic valve includes two main flow outlets and two control flow inlets. The experiments were conducted with pressure regulators, mass flow meters, and piezo sensors to analyze flow switching characteristics of the fluidic valve. The experimental data such as pressure and mass flow rate of control flows and the switching time of the main flow was obtained with various operating conditions. The operation limit of the fluidic valve is identified, and a model equation for pre-estimating the minimum control pressure to switch the direction of the main flow has been proposed.

관류형 보일러의 온도제어 (Temperature control for once through boiler)

  • 김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.900-904
    • /
    • 1991
  • It is important and difficult to control the steam temperature in the once through boiler. Generally, steam temperature of once through boiler not only is controlled by boiler spray water flow, but also is influenced by feed water flow and fuel flow. So we have to make the same gain of fuel flow controller and feed water flow controller. This paper is shown the design and test of steam temperature and feed water flow control system for once through boiler in pusan thermal power plant.

  • PDF

오리피스를 이용한 엔진 윤활시스템 유량분배 제어 (Oil Flow Distribution Control of Engine Lubrication System Using Orifice Component)

  • 윤정의
    • Tribology and Lubricants
    • /
    • 제22권1호
    • /
    • pp.47-52
    • /
    • 2006
  • It is very important to control pressure and flow rate distribution on each component of engine lubrication network. Sometimes many kinds of orifice are used to control flow rate in the hydraulic lubrication field. In this study orifices were adopted on the lubrication network to control oil flow rate distribution. And unsteady transient flow network analysis was carried out to find out the effects of orifices on the engine oil circuit system.

산업용 밸브의 유량제어 시스템 설계 (Flow Rate Control System Design for the Industrial Valve)

  • 최정주
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.387-392
    • /
    • 2020
  • 본 논문은 산업용 밸브의 유량제어시스템을 제안하였다. 산업용 밸브는 주로 배관시스템에 장착되어 유량 및 압력 제어에 사용된다. 제어밸브의 구조 및 작동 방식은 설치환경과 작업용도에 따라 상이하다. 밸브는 그 형태에 따라 그루브 밸브, 버터플라이 밸브 및 볼 밸브 등으로 분류되고, 구동방식은 모터를 이용하거나, 유압 및 공압을 이용하는 것이 일반적이다. 제어밸브를 이용한 유량제어시스템은 유량을 계측하여 피드백시스템을 구현하여야 하지만, 본 논문에서는 고가의 유량센서를 사용하지 않고 밸브의 개폐에 따른 유량변화를 실험하여 밸브 전후단의 압력차와 개폐정도를 이용하는 방법을 제안하였다. 밸브의 유량은 유량계수를 이용하여 밸브 전후단의 압력차와 밸브의 개폐정도로 표현할 수 있으므로 이를 이용하여 유량제어시스템을 설계하였다. 제어입력에 따른 밸브의 개폐를 나타내는 전달함수는 신호압축법을 이용하여 구하였으며, 이를 이용하여 밸브 스템의 명령추종성능을 향상시킬 수 있는 외란관측기를 설계하였다. 제안된 제어시스템의 성능을 검증하기 위해 제어밸브 전후단에 압력센서를 장착하여 제안된 제어방법의 성능이 유량센서를 이용한 경우에 준함을 확인하였다.

A Two-Dimensional Study of Transonic Flow Characteristics in Steam Control Valve for Power Plant

  • Yonezawa, Koichi;Terachi, Yoshinori;Nakajima, Toru;Tsujimoto, Yoshinobu;Tezuka, Kenichi;Mori, Michitsugu;Morita, Ryo;Inada, Fumio
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.58-66
    • /
    • 2010
  • A steam control valve is used to control the flow from the steam generator to the steam turbine in thermal and nuclear power plants. During startup and shutdown of the plant, the steam control valve is operated under a partial flow conditions. In such conditions, the valve opening is small and the pressure deference across the valve is large. As a result, the flow downstream of the valve is composed of separated unsteady transonic jets. Such flow patterns often cause undesirable large unsteady fluid force on the valve head and downstream pipe system. In the present study, various flow patterns are investigated in order to understand the characteristics of the unsteady flow around the valve. Experiments are carried out with simplified two-dimensional valve models. Two-dimensional unsteady flow simulations are conducted in order to understand the experimental results in detail. Scale effects on the flow characteristics are also examined. Results show three types of oscillating flow pattern and three types of static flow patterns.