• Title/Summary/Keyword: Control Error

Search Result 6,612, Processing Time 0.039 seconds

Optimization-based Deep Learning Model to Localize L3 Slice in Whole Body Computerized Tomography Images (컴퓨터 단층촬영 영상에서 3번 요추부 슬라이스 검출을 위한 최적화 기반 딥러닝 모델)

  • Seongwon Chae;Jae-Hyun Jo;Ye-Eun Park;Jin-Hyoung, Jeong;Sung Jin Kim;Ahnryul Choi
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.331-337
    • /
    • 2023
  • In this paper, we propose a deep learning model to detect lumbar 3 (L3) CT images to determine the occurrence and degree of sarcopenia. In addition, we would like to propose an optimization technique that uses oversampling ratio and class weight as design parameters to address the problem of performance degradation due to data imbalance between L3 level and non-L3 level portions of CT data. In order to train and test the model, a total of 150 whole-body CT images of 104 prostate cancer patients and 46 bladder cancer patients who visited Gangneung Asan Medical Center were used. The deep learning model used ResNet50, and the design parameters of the optimization technique were selected as six types of model hyperparameters, data augmentation ratio, and class weight. It was confirmed that the proposed optimization-based L3 level extraction model reduced the median L3 error by about 1.0 slices compared to the control model (a model that optimized only 5 types of hyperparameters). Through the results of this study, accurate L3 slice detection was possible, and additionally, we were able to present the possibility of effectively solving the data imbalance problem through oversampling through data augmentation and class weight adjustment.

Dissolved Methane Measurements in Seawater and Sediment Porewater Using Membrane Inlet Mass Spectrometer (MIMS) System (Membrane Inlet Mass Spectrometer (MIMS) 시스템을 이용한 해수 및 퇴적물 공극수내 용존 메탄의 측정)

  • An, Soon-Mo;Kwon, Ji-Nam;Lim, Jea-Hyun;Park, Yun-Jung;Kang, Dong-Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2007
  • Membrane inlet mass spectrometer (MIMS) has been used to accurately quantify dissolved gases in liquid samples. In this study, the MIMS system was applied to measure dissolved methane in seawater and sediment porewater. To evaluate the accuracy of the measurement, liquid samples saturated with different methane partial pressure were prepared and the methane concentrations were quantified with the MIMS system. The measured values correspond well with the expected values calculated from solubility constants. The standard error of the measurements were $0.13{\sim}0.9%$ of the mean values. The distribution of dissolved methane concentration in seawater of the South Sea of Korea revealed that the physical parameters primarily control the methane concentration in sea water. The MIMS system was effective to resolve the small dissolved methane difference among water masses. The probe type inlet in MIMS system was proven to be effective to measure porewater methane concentration.

Manufacture and Qualification of Composite Main Reflector of High Stable Deployable Antenna for Satellite (위성용 전개형 고안정 반사판 안테나 주반사판 제작 및 검증)

  • Dong-Geon Kim;Hyun-Guk Kim;Dong-Yeon Kim;Kyung-Rae Koo;Ji-min An;O-young Choi
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.219-225
    • /
    • 2024
  • It is essential to develop a light-weight, high-performance structure for the deployable reflector antenna, which is the payload of a reconnaissance satellite, considering launch and orbital operation performance. Among them, the composite main reflector is a key component that constitutes a deployable reflector antenna. In particular, the development of a high-performance main reflector is required to acquire high-quality satellite images after agile attitude control maneuvers during satellite missions. To develop main reflector, the initial design of the main reflector was confirmed considering the structural performance according to the laminate stacking design and material properties of the composite main reflector that constitutes the deployable reflector antenna. Based on the initial design, four types of composite main reflectors were manufactured with the variable for manufacturing process. As variables for manufacturing process, the curing process of the composite structure, the application of adhesive film between the carbon fiber composite sheet and the honeycomb core, and the venting path inside the sandwich composite were selected. After manufacture main reflector, weight measurement, non-destructive testing(NDT), surface error measurement, and modal test were performed on the four types of main reflectors produced. By selecting a manufacturing process that does not apply adhesive film and includes venting path, for a composite main reflector with light weight and structural performance, we developed and verified a main reflector that can be applied to the SAR(Synthetic Aperture Rader) satellite.

Usability Evaluation Criteria Development and Application for Map-Based Data Visualization (지도 기반 데이터 시각화 플랫폼 사용성 평가 기준 개발 및 적용 연구)

  • Sungha Moon;Hyunsoo Yoon;Seungwon Yang;Sanghee Oh
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.58 no.2
    • /
    • pp.225-249
    • /
    • 2024
  • The purpose of this study is to develop an evaluation tool for map-based data visualization platforms and to conduct heuristic usability evaluations on existing platforms representing inter-regional information. We compared and analyzed the usability evaluation criteria of map-based platforms from the previous studies along with Nielsen's (1994) 10 usability evaluation principles. We proposed nine evaluation criteria, including (1) visibility, (2) representation of the real world, (3) consistency and standards, (4) user control and friendliness, (5) flexibility, (6) design, (7) compatibility, (8) error prevention and handling, and (9) help provision and documentation. Additionally, to confirm the effectiveness of the proposed criteria, four experts was invited to evaluate five domestic and international map-based data visualization platforms. As a result, the experts were able to rank the usability of the five platforms using the proposed map-based data visualization usability evaluation criteria, which included quantified scores and subjective opinions. The results of this study are expected to serve as foundational material for the future development and evaluation of map-based visualization platforms.

Development and validation of enzyme-linked immunosorbent assay for anti-mouse pertussis immunoglobulin G using international reference anti-Bordetella pertussis mouse serum NIBSC 97/642

  • Kyu-Ri Kang;Yi-Hyeon Kwon;Gyu-Won Cho;Gi-Sub Choi;Joon-Hwan Ji;Hyun-Mi Kang;Soo-Young Lee;Jin-Han Kang
    • Clinical and Experimental Vaccine Research
    • /
    • v.13 no.3
    • /
    • pp.242-252
    • /
    • 2024
  • Purpose: In this study, an in-house enzyme-linked immunosorbent assay (ELISA) was developed and validated. The titer of ELISA was calculated using the reference line (RFL) method based on the standard curve drawn using the international reference anti-mouse serum NIBSC (National Institute for Biological Standards and Control) 97/642. Materials and Methods: In the development step, signal to noise was depicted to select the buffers that showed the most appropriate ratio. In the validation step, standard range, precision, dilution linearity, and specificity were confirmed, and RFL and parallel line (PLL) methods were compared in precision and dilution linearity. Results: Coating concentration for plate was achieved at 0.1 ㎍/mL for pertussis toxin (PT), 0.15 ㎍/mL for filamentous hemagglutinin antigen (FHA), and 0.25 ㎍/mL for pertactin (PRN). The signal to noise ratio was 22.02 for PT, 14.93 for FHA, and 8.02 for PRN with 0.25% goat serum in phosphate-buffered saline (PBS) as a dilution buffer, and 2% skim milk in PBS as a blocking buffer. Based on the precision results, we assessed the lower limit of quantification by 1, 0.2, and 1.5 EU/mL concentration for PT, FHA, and PRN which met the ICH (International Council for Harmonization) M10 criteria of a 25% accuracy and total error of 40%. In specificity, homologous serum was spiked into heterologous serum and the accuracy met the criteria. There was no difference in the results between RFL and PLL calculations (p-value=0.3207 for PT, 0.7394 for FHA, 0.2109 for PRN). Conclusion: ELISA validated with RFL calculation method in this study is a relatively accurate assay for mouse humoral immunogenicity test.

Atmospheric Disturbance Simulation in Adaptive Optics: from Theory to Practice (적응광학에서의 대기 외란 모사: 이론에서 실제 적용까지)

  • Jun Ho Lee;Ji Hyun Pak;Ji Yong Joo;Seok Gi Han;Yongsuk Jung;Youngsoo Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.5
    • /
    • pp.199-209
    • /
    • 2024
  • Predicting the performance of adaptive optics systems is a crucial step in their design and analysis. First-order prediction methods, based primarily on several assumptions and scaling laws, are commonly used. These methods must account for various parameters and error sources, such as the intensity and profile of atmospheric turbulence, fitting errors based on the resolution of the wavefront sensor and deformable mirror, wavefront-sensor noise propagated through the wavefront-reconstruction algorithm, servo lag due to the finite bandwidth of the control loop, and anisoplanatism caused by the arrangement of natural and laser guide stars. However, since first-order performance-prediction methods based on certain assumptions can sometimes yield results that deviate from real-world performance, evaluation through computational simulations and closed-loop tests on a testbed is necessary. Additionally, an atmospheric simulator is required for closed-loop testing, which must adequately simulate the spatial and temporal characteristics of atmospheric disturbances. This paper aims to present an overview of the theory of atmospheric disturbance simulators, as well as their implementation in computational simulation and hardware.

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program (OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선)

  • Back, Song-Ran;Kim, Sung-Ho;Yoo, So-Yeon;Kim, Nyun-Ok;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.185-188
    • /
    • 2009
  • Purpose: Standard of retests were discrepant and inconsistent due to inaccuracy and lack of standardization within normal range limit of tumor marker test. To enhance the standardization of retests set standard value below normal range and the Order Communication System Quality Control (OCS QC) program was put in place. This program enables managing the results within lower limit of normal range which were used for tumor marker test in Health Center. Materials and Methods: At present the tumor marker study for AFP, CEA, CA19-9, CA125, and PSA included outpatients in Asan Medical Center from February to March, 2009. The standard value was obtained by using the percentage of CV of Inter Assay according to the normal range of each tumor test. The results were confirmed by using the OCS QC program via formatted assessment of screening test such as test items, standard value and medical department. The number of out-of-range results within plus and minus 30 percents regarding the five primary items of tumor marker test was assessed. The next step was to obtain the number of AFP, CEA, and CA125 according to the ratio of comparison between prior and post test result, 60%, 50%, and 40% within normal range, respectively. In addition, set standard value below normal range. Results: The first screening test with percentage of sample number was resulted between 30%-40% and the second one was AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA125 18.7%, and PSA 21.0% obtained screening percentage of average 20 percents. The limited value of retest was AFP less than 5.0 and more than 10.0, CEA less than 1.0 and more than 3.0, CA19-9 less than 10.0 and more than 30.0, and PSA less than 1.0 and more than 2.0 to set and the number of retest was obtained by applying to the limited value of retest to screening percentage of average 20 percents For two months, the number of retest was AFP 0, CEA 15, CA19-9 3, CA125 2, and PSA 5. Conclusions: Through using the OCS QC program in establishing the standard of retest systemically, there appeared to be reduced discrepancy among the examiners and to be expected improvement in relation to the error of results.

  • PDF

Effect of Night and Daytime Temperatures on Growth and Yield of Paprika 'Fiesta' and 'Jubilee' (${\cdot}$야 온도가 착색단고추의 생육 및 수량에 미치는 영향)

  • Choi Young Hah;Kwon Joon Kook;Lee Jae Han;Kang Nam Jun;Cho Myeong Whan;Kang Jum Soon
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.226-232
    • /
    • 2004
  • This experiment was conducted to investigate the effect of night and daytime temperatures on growth and yield of paprika 'Fiesta' and 'Jubilee' under soil culture experiment in the vinyl houses during the 2003 and 2004 season. Total fruit yield was greater in 'Fiesta' than 'Jubilee' Marketable yield was not different between two cultivars, due to lower $\%$ marketable fruits in 'Fiesta'. mean Fruit weight was not different between two cultivars. Difference of yield between cultivars was due to fruit number, harves time and root condition. It was caused by cracked fruits to decrease $\%$ marketable fruits. Total yield was greater in nighttime temperature of $18^{\circ}C\;than\;15^{\circ}C$ and marketable yield was considerably greater because of $\%$ marketable fruits was higher. Mean fruit weight was slightly greater in nighttime temperature of $15^{\circ}C\;than\;18^{\circ}C$. Difference of fruit yield in treatments of nighttime temperature was due to fruit number and harvest time. There was not significant difference of yield between daytime temperature of $28^{\circ}C\;and\;31^{\circ}C$, but in $34^{\circ}C$, total and marketable yields were the least and mean fruit weight was the smallest because of decreased $CO_2$ concentration in the house, accerated vegetative growth, and the least chlorophyll content. There were no significant difference in photosynthetic rate, transpiration rate, maximal photochemical efficiency and antioxidant enzyme activities of all temperature treatments in this experiment. However it was clear that a little difference in error range of these results affects the source of crops in any case. It was not acknowledged that compensation effect by high temperature in daytime to the low temperature treatment in nighttime.

Design Factor Analysis of End-Effector for Oriental Melon Harvesting Robot in Greenhouse Cultivation (시설재배 참외 수확 로봇용 엔드이펙터의 설계 요인 분석)

  • Ha, Yu Shin;Kim, Tae Wook
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.284-290
    • /
    • 2013
  • This study analyzed the geometric, compressive, cutting and friction properties of oriental melons in order to design a gripper capable of soft handling and a cutter for cutting oriental melon vine among the end effector of oriental melon as a preliminary step for developing the end effector of the robot capable of harvesting oriental melons in protected cultivation. As a result, the average length, diameter at the midpoint, weight, volume and roundness of the oriental melons were 108 mm, 70 mm, 188 g, 333 mL and 3.8 mm. Nonlinear regression analysis was performed on the equation $W=L^a{\times}D_2^b$ with variation of the length (L) and diameter (D2) of the weight (W) of the oriental melons. As a result, it was shown that there was a correlation between a of 2.0279 and b of -0.9998 as a constant value. The average diameter of the oriental melon vine was 3.8 mm, and most vines were distributed within a radius of 5 mm from the center. The average yield value, compressive strength and hardness of the oriental melons were $36.5N/cm^2$, $185.7N/cm^2$ and $636.7N/cm^2$, respectively. The average cutting force and shear strength of the oriental melon vines were $2.87{\times}10^{-2}\;N$ and $5.60N/cm^2$, respectively. The maximum friction coefficient of the oriental melons was rubber of 0.609, followed by aluminium of 0.393, stainless steel of 0.177 and teflon of 0.079. It was considered possible to apply it to the size of the gripper and cutter, turning radius, dynamics of drive motor and selection of materials and their quality in light of the position error and safety factor according to the movement when designing end effector based on the analyzed data.