• Title/Summary/Keyword: Control %26 Monitoring system

Search Result 65, Processing Time 0.021 seconds

Construction and basic performance test of an ICT-based irrigation monitoring system for rice cultivation in UAE desert soil

  • Mohammod, Ali;Md Nasim, Reza;Shafik, Kiraga;Md Nafiul, Islam;Milon, Chowdhury;Jae-Hyeok, Jeong;Sun-Ok, Chung
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.703-718
    • /
    • 2021
  • An irrigation monitoring system is an efficient approach to save water and to provide effective irrigation scheduling for rice cultivation in desert soils. This research aimed to design, fabricate, and evaluate the basic performance of an irrigation monitoring system based on information and communication technology (ICT) for rice cultivation under drip and micro-sprinkler irrigation in desert soils using a Raspberry Pi. A data acquisition system was installed and tested inside a rice cultivating net house at the United Arab Emirates University, Al-Foah, Al-Ain. The Raspberry Pi operating system was used to control the irrigation and to monitor the soil water content, ambient temperature, humidity, and light intensity inside the net house. Soil water content sensors were placed in the desert soil at depths of 10, 20, 30, 40, and 50 cm. A sensor-based automatic irrigation logic circuit was used to control the actuators and to manage the crop irrigation operations depending on the soil water content requirements. A developed webserver was used to store the sensor data and update the actuator status by communicating via the Pi-embedded Wi-Fi network. The maximum and minimum average soil water contents, ambient temperatures, humidity levels, and light intensity values were monitored as 33.91 ± 2 to 26.95 ± 1%, 45 ± 3 to 24 ± 3℃, 58 ± 2 to 50 ± 4%, and 7160-90 lx, respectively, during the experimental period. The ICT-based monitoring system ensured precise irrigation scheduling and better performance to provide an adequate water supply and information about the ambient environment.

Development of a Linear Chemigation System (가로주행식 케미게이션 시스템의 개발)

  • 구영모;배영환;박금주;정상옥
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.93-104
    • /
    • 2001
  • A linear chemigation system, integrating agrichemical appication units of pesticide and fertilizer into an irrigation system, was selected as a suitable model for the cost savings in farm management and automation. Technical designs were conducted in the areas of structure, power, drive, control, and hydraulic systems. An experimental farm was sectioned into the fields of 40m by 200m and systemized with the linear-move chemigation system of 36m in span. The chemigation system consisted of a base unit monitoring and controlling overall operation, and a driving unit traveling linearly and injecting agrichemicals. Monitoring and interlocking systems were utilized against unexpected malfunctions of power, injection and drive systems using radio freuency modems between the units. The system can be also modified to various farm sizes and stationary systems of indoor and outdoor.

  • PDF

The Study on the Integrated Emergency Management System using Network GR-type Receiver and Control Desk (네트워크 GR형 수신기와 컨트롤데스크를 이용한 통합방재관리시스템에 대한 연구)

  • Baek, Dong-Hyun;Song, Ho-Bin;Kang, Won-Shun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • The buildings of domestic wear the upper floors and an underground in-depth reconciliation tendency to do and the possibility of fire occurrence at the time of formation accident is coming to be high. Therefore will be scattered to various place and is established and prevention of disaster information of the receiver which will integrate there is a necessity which will manage. In this paper away where each receiver is installed in the fire for the remote monitoring and controld able to connect to the Internet and fiber optic cable that can be networked fire receiver and control desk was constructed. Between each device can be used by the fire, and more depending on the status of monitoring and alarm, control and maintenance can be performed to develop an integrated management system. The system is evaluated by the criteria of the KFI, and for each segment of the signal propagation time to perform experiments confirmed the reliability of the performance.

Robust Control Chart using Bootstrap Method (붓스트랩 방법을 이용한 로버스트 관리도)

  • 송서일;조영찬;박현규
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.26 no.3
    • /
    • pp.39-49
    • /
    • 2003
  • Statistical process cintrol is intended to assist operators of a stable system in monitoring whether a change has occurred in the process, and it uses several control charts as main tools. In design and use of control chart, it is rational that probability of false alarm is minimized in stable process and probability of detecting shifts is maximized in out-of-control. In this study, we establish bootstrap control limits for robust M-estimator chart by applying the bootstrap method, called resampling, which could not demand assumptions about pre-distribution when the process is skewed and/or the normality assumption is doubt. The results obtained in this study are summarized as follows : bootstrap M-estimator control chart is developed for applying bootstrap method to M-estimator chart, which is more robust to keep ARL when process contain contaminate quality characteristic.

Margin Benefit Assessment of A Digital Monitoring System for Existing Analog Plants (기존 아날로그 발전소를 위한 디지탈 감시계통의 여유도 잇점평가)

  • Auh, Geun-Sun;Yoon, Tae-Young
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.294-299
    • /
    • 1994
  • Margin benefits are quantatively assessed when a Digital Monitoring System(DMS) is assumed to be installed to an operating Westinghouse analog type plant. Applied plant and cycle is YongGwang Unit 1 Cycle 6. The referenced digital monitoring system is the COLSS (Core Operating Limit Supervisory System) of ABB-CE. Considered fuel design limits are DNBR and LDCA Fq. 2003-D Power distributions within the present CAOC (Constant Axial Offset Control) limits are calculated for the analysis. The most limiting DNB prevention event of CEA Withdrawal is analyzed with the ROPM (Required OverPower Margin) concept of ABB-CE. The result show that the DMS can bring around 7% more margins for both DNB and LOCA Fq standpoints of view. The DMS can also monitor the PCI (Pellet-Cladding Interaction) limits.

  • PDF

A Study of Computerized Industrial Hygiene Control System (작업환경관리 전산화에 관한 연구)

  • Lee, Song Kwon;Lee, Young Sei;Kim, Young Su;Kim, Yong Lae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.117-126
    • /
    • 1994
  • Some of the important and vital roles performed by the Health Care Center of Pohang Iron & Steel Co., Ltd.(POSCO) are the periodic monitoring of the work sites as well as regular medical check-ups for each workers to ensure both pleasant and safe working conditions and to protect employees' health. Pohang Steel Works, which has 42 plants, 26 facilities and 12,000 employees, has an annual crude steel production capacity of 9,670,000 using 24,500,000 ton of raw materials. We have measured lots of areal and personal working environment according to Occupational Safety and Health Law semiannually. All data collected on industrial hygiene is stored and managed by personal computer. The developed of a computerized industrial hygiene control system linked to the company's main computer system will provide efficient evaluation of the working environment as well as critical informations on employees' health. Development of this system had begun in May, 1992 and was completed in March, 1994. The computerized industrial hygiene control system can; 1. store industrial hygiene data, providing key pertinent to the diagnosis of occupational related illnesses, and if necessary, the basis for improving the working environment, 2. decide type and time of medical examination of each work for exposure to specific agents, and supply proper protection periodically, 3. prevent occupational related illnesses through evaluation of environmental and biological monitoring, and performance of epidemiological surveillance, 4. facilitate proper job placement through linking of industrial hygiene control and personnel information systems, 5. monitor job processes. levels of chemical agents used, and new agents introduced, 6. and increase productivity by saving time resulting from the implementation of the computerized sysyte,

  • PDF

Multivariate Exponentially Weighted Moving Average(EWMA) Process Control and Statistical Process Monitoring in the Process Industry (장치산업에서 다변량 EWMA 공정제어와 통계적 공정감시)

  • 김복만;최성운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.15 no.26
    • /
    • pp.119-124
    • /
    • 1992
  • 본 논문은 장치산업에서 적용되는 다변량 EWMA 공정제어와 통계적 공정감시 통합시스템을 제안한다. 본 논문에서 제안한 통합시스템은 자동공정제어(APC)의 예측, 조정기능과 통계적 정정감시(SPM)의 이상점 발견 및 제거등의 각각의 장점을 이용하였다. 기존의 다변량 EWMA연구는 데이타간의 독립성을 가정하였으나 본 논문은 데이타간의 종속적인 형태인 IMA(1,1)모델을 대상으로 하였다.

  • PDF

Development of Low-Cost Automatic Flight Control System for an Unmanned Target Drone (무인표적기용 저가형 자동비행시스템 개발)

  • Lee, Jang-Ho;Ryu, Hyeok;Kim, Jae-Eun;Ahn, Iee-Ki
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 2004
  • This paper deals with the automatic flight control system for an unmanned target drone which is operated by an army as an anti-air gun shooting training. By automation of unmanned target drone that is manually operated by external pilot, pilot can reduce workload and an army can reduce the budget. Most UAVs which are developed until today use high-cost sensors as AHRS and IMU to measure the attitude, but those are contradictory for the reduction of budget. This paper says the development of low-cost automatic flight control system which makes possible of automatic flight with low-cost sensors. We have developed the integrated automatic flight control system by integrating electricity module, switching module, monitoring module and RC receiver as an one module. We also prove the performance of automatic flight control system by flight test.

  • PDF

The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System (해양환경 정도관리제도 운영에 대한 고찰)

  • PARK, MI-OK;PARK, JUN-KUN;KIM, SEONG-GIL;KIM, SEONG-SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.185-200
    • /
    • 2021
  • The Marine Environment QA/QC management system has been operated since 2010 to secure the reliability of data and improve the analysis capabilities of measurement and analysis institutions. From 2010 to 2020, the cumulative number of measurement and analysis institutions participated in the QA/QC management system was 266. And the number of certificates issued by the ministry of oceans and fisheries is 182. A total of 32 reference materials for proficiency testing and interlaboratory comparisons have been developed. They were first developed focusing on items (Nutrients, COD) commonly analyzed in marine environmental measuring network, marine pollution impact surveys, sea area utilization impact assessment, deepsea water surveys, and information network on fishing ground environments. In addition, it is time to expand the filed of the QA/QC management system, such as seawater temperature, salinity, PCBs and PAHs in sediments, which are mainly analyzed in most monitoring programs. On-site assessment has been conducted for 162 laboratories according to ISO/IEC 17025 to evaluate their conformity of the quality management system and deficiency. In terms of management and technology requirements, about 4.2% of organizations showed insufficient division of duties among employees 8.7% of them revealed the lack of employee training. By test item, about 6.3% of organizations showed the lack of standard substance management and the state of the cleaning glassware was pointed out in about 5.4% of them. The QA/QC management system should be continuously supplemented by identifying the causes of nonconformities and area for improvement.

Real-time Fault Detection in Semiconductor Manufacturing Process : Research with Jade Solution Company

  • Kim, Byung Joo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.2
    • /
    • pp.20-26
    • /
    • 2017
  • Process control is crucial in many industries, especially in semiconductor manufacturing. In such large-volume multistage manufacturing systems, a product has to go through a very large number of processing steps with reentrant) before being completed. This manufacturing system has many machines of different types for processing a high mix of products. Each process step has specific quality standards and most of them have nonlinear dynamics due to physical and/or chemical reactions. Moreover, many of the processing steps suffer from drift or disturbance. To assure high stability and yield, on-line quality monitoring of the wafers is required. In this paper we develop a real-time fault detection system on semiconductor manufacturing process. Proposed system is superior to other incremental fault detection system and shows similar performance compared to batch way.