• 제목/요약/키워드: Contrast-Detail phantom

검색결과 11건 처리시간 0.024초

Contrast-Detail Phantom을 이용한 CR에서 Image Plate의 사용 횟수에 따른 Contrast-Detail Curve의 변화

  • 이승철;박장흠;김재동;박창현
    • 대한디지털의료영상학회논문지
    • /
    • 제7권1호
    • /
    • pp.7-13
    • /
    • 2005
  • Purpose : Image plate (IP) is substituted for film in computed radiography. This study is to investigate into a variation of contrast and detail by the number used of image plate in computed radiography. Materials and Methods : A Contrast-Detail(CD)-RAD 2.0 phantom(Nijmegen hospital, The Netherlands) was used for this study. The computed radiography(CR) CD-RAD phantom images were acquired at 40 kVp, 160 mA, 1.6 mAs, and small focus with the Shimadzu general radiography UD-150B-10 system and Fuji FCR 5000 image process system with speed of 200. The IP used including once, 5000 times, and 10000 times also was used. The numerical value of image quality figures (IQF) was produced by CD-RAD analyser(the program is installed in the directory), and then contrast-detail curve was drawn. Results : In this study, the value of IQF was 3.53 in IP used once, 3.40 in 5000 times, and 3.22 in 10000 times. Conclusions : There was a variation of contrast-detail curve by the number used of IP with contrast-detail phantom in computed radiography. Therefore, it is necessary that the IP with lower IQF and a shift of contrast-detail curve to the lower left part is used.

  • PDF

A-Se 기반 디지털 X-선 영상장치의 Contrast-detail 특성 평가 (Evaluation of Contrast-detail Characteristics of an A-Se Based Digital X-ray Imaging System)

  • 현혜경;박소현;김근영;조희문;조효성
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.11-16
    • /
    • 2007
  • 본 연구에서는 a-Se 기반 디지털 X-선 영상장치의 저대조도 특성을 평가하기 위하여 contrast-detail 곡선 해석을 수행하였다. 본 실험에 사용된 X-선 영상장치는 픽셀크기가 $139mm{\times}139mm$이고 유효면적이 $46.7cm{\times}46.7cm$인 a-Si TFT 기판 위에 500mm 두께의 광전도체가 코팅된 구조를 갖고 있다. Contrast-detail 곡선을 측정하기 위하여 우선 주어진 촬영조건(즉, 40, 50, 60, 70, 80 kVp, and 16 mA.s)에서 상용 팬톰인 CDRAD 2.0을 사용하여 X-선 영상을 획득한 후, 그 영상으로부터 IQFinv 인자를 사용하여 그 특성을 최종 평가하였다. 평가된 IQFinv 값은 주어진 광 플루언스(즉, $1.8{\times}105$, $5.9{\times}105$, $11.3{\times}105$, $19.4{\times}105$, and $29.4{\times}105$ photons/$mm^2$)에서 각각 24.4, 35.3, 39.2, 41.5, 43.4으로 광 플루언스가 증가할수록 점진적으로 증가하였으며 이는 광 플루언스가 증가할수록 영상의 가독성이 향상됨을 나타낸다.

  • PDF

CD-RAD Phantom을 이용한 의료영상의 분석 (Analysis of Medical Image with CD-RAD Phantom)

  • 김창복;김영근;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.369-369
    • /
    • 2007
  • 본 연구에서는 CD-RAD Phantom을 이용하여 의료영상의 명세성 (image clarity)분석을 위하여 동일한 X선 영상을 대상으로 물리적 평가와 시각적 평가를 비교분석 하였다. 측정방법은 CD-RAD Phantom을 X선 조사하여 CR 영상처리장치를 통해 영상을 획득하였으며, 영상분석은 CD-RAD analyser program을 통한 통계학적 방법으로 물리적 평가를 시행하고, 동일한 영상의 시각적 평가는 관찰자 20명을 대상으로 blind test를 시행하였다. 분석결과는 Contrast-detail curve의 물리적 평가 IQF값은 25, 시각적 평가 IQF값은 30으로 분석되어 물리적 평가가 시각적 평가에 비해 우수하게 나타났다. 의료영상의 특성은 영상 판독자에게 영상의 정보 전달능력이 매우 중요하므로 객관적인 물리적 분석법과 시각적 분석법이 병행되어야 한다고 판단된다.

  • PDF

웨이브렛과 기저 계수를 이용한 X-ray 영상의 대조도 향상기법 (Contrast Enhancement for X-ray Images Based on Combined Enhancement of Scaling and Wavelet Coefficients)

  • 박천주;김도일;장도윤;윤한빈;최보영;김호경;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.150-156
    • /
    • 2008
  • 본 연구에서는 이산 웨이브렛 도메인에서 기저계수와 웨이브렛 계수의 변환을 이용하여 X-ray 이미지의 대조도를 향상시키는 방법을 제안하였다. 기저 함수의 변환은 기존에 나와있는 contrast limited adaptive histogram equalization (CLAHE)와 multi-scale image contrast amplification (MUSICA)와 같은 보편적인 영상의 대조도 향상 기법을 적용하였으며 대조도가 향상된 저해상도 기저 계수의 역변환으로 인한 Blurring 현상을 방지하고 또한 이미지의 선명도를 향상시키기 위하여 웨이브렛 계수에 sigmoid function을 적용하였다. 본 알고리즘에 대한 성능 평가를 위하여 contrast detail mammography(CDMAM) 팬텀의 영상을 획득하여 기존에 사용한 대조도 향상 기법들과 contrast to noise ratio (CNR) 및 line profile에 대한 비교평가를 실시 하였고 그 결과 기존의 대조도 향상기법을 웨이브렛 도메인에서 적용하는 것이 뛰어나다는 것을 알 수 있었다. 본 영상 대조도 향상기법은 영상의 대조도를 증가시키는 동시에 잡음의 증폭을 효율적으로 억제할 수 있다. 따라서 본 연구는 의료 영상뿐 만이 아닌 대조도와 선명도가 중요시되는 여려 분야에 적용될 수 있으리라 기대된다.

  • PDF

X선촬영시(X線撮影時) 피사체(被寫體) 두께에 따른 격자비(格子比) 선정(選定)에 관한 연구(硏究) (Studios in Selected Grid Ratio of Objective Thickness on X-ray Exposure)

  • 윤철호;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.21-34
    • /
    • 1982
  • When unattenuated x-ray radiation passes through the object it is transmitted and scattered from objectes and impinging on the film. During this process certain radiation is absorbed within the object and others transmitted in reduced scattering. The scattering radiation influence upon radiation image quality, confining x-ray beam which means scattering radiation produce increased fog on x-ray film image and as a consequence decrease contrast and less detail of the film there for the elimination of fog and for absorbing scattered radiation, the grid has been used between the object and the film in order to rid of scattering rays. Using grid is good method for the qualification of the better image as well as in using air gap technique. The grid is easy to manipulate and promote good efficiency which is defined by ICRU and JIS. It is the purpose to study for eliminating scattered radiation from the tissue equivalent acryl phantom using grid, we have studied and evaluated the grid permeability about the x-ray exposure, the selection of grid ratio according to phantom thickness, on x-ray exposure are performed as follows. 1. The penetrating ratio of primary x-ray is remarkably decreased by increasing of the grid ratio, but it is almost not influenced in KVP difference and phantom thickness. 2. The scattered radiation is proportionaly increased by thickness of the phantom, having nothing to do with grid ratios. 3. The relative between the penetration rate of primary and secondary x-ray is improved by increasing grid ratio, and decreased by phantom thickness, and slightly decreased by high tube voltage. 4. The grid of 5:1 and 10:1 ratio are adequate to the phantom of 10cm and 15cm thickness, respectively.

  • PDF

CT 정도관리를 위한 인공지능 모델 적용에 관한 연구 (Study on the Application of Artificial Intelligence Model for CT Quality Control)

  • 황호성;김동현;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권3호
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가 (Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography)

  • 이인자;김유현;김창남;이창엽;박계연
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.25-32
    • /
    • 2009
  • 흉부 DR 촬영 시 적당한 촬영조건을 알아보기 위해 C-D phantom을 이용한 영상의 평가를 식별능과 입상성 및 선량의 관계로 알아본 결과 다음과 같은 결론을 얻었다. 1. 환자 입사선량(ESE)은 관전압이 증가됨에 따라 감소되었다. 2. 노출조건 중 관전압 변화에 따른 C-D phantom의 식별능은 110 kVp에서 가장 잘 보이는 것으로 나타났다. 3. 노출비(mAs) 변화에 따른 식별능은 낮은 노출비(0.5배)에서는 90 kVp에서 가장 잘 보였으며, 노출비가 (1.5배)인 경우 110 kVp에서 가장 잘 보임을 알 수 있었고, 노출을 많이 했을 때가 식별이 잘 됨을 알 수 있었다. 4. 관전압 110 kVp에서 노출비에 따른 입상성은 1.5배일 때가 가장 좋으며, 노출비 1.5배일 때 관전압 변화 시 입상성은 110 kVp일 때가 가장 좋다. 따라서 환자의 피폭선량(Detector에 입사되는 선량은 동일)은 kVp 증가 시 작으며, 적당한 kVp는 110, 선량비는 1.0배에 비해 1.5배로 양을 많이 주었을 때가 식별이 잘 되었고, 입상성 또한 노출비가 1.5배일 때 좋으며 관전압은 110 kVp일 때가 좋았다. 그러나 노출비를 많이 주면 환자가 받는 선량이 증가됨으로 본 연구에 의하면, 노출조건을 신중히 설정하여야 할 것이다.

  • PDF

디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구 (The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography)

  • 신수인;김종일;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • 의학적으로 방사선을 사용 시 가장 중요한 점은 환자의 병을 진단 가능하되 피폭선량을 최소화시켜야 한다는 점이다. 진단용 X-선 중 장파장부분은 대부분 흡수에 관여하게 되어 환자의 피폭선량을 증가시키므로 불필요하다. 이러한 장파장영역을 제거하기 위한 방법으로 가장 효과적인 방법은 여과 판의 사용이다. 이에 부가여과가 없는 경우와 0.3mmCu filter 사용 시의 화질과 피부입사선량에 대해 실험을 해 보았다. ROC 신호용 지름 4mm, 두께 3mm의 아크릴 디스크를 chest phantom에 랜덤하게 위치시키면서 non filter 및 Cu filter시 각 각 20매씩 총 40매의 신호+잡음영상을 촬영하고, 또한 신호가 없는 영상(잡음만의 영상)을 각 각 20매씩 40매 촬영하여 총 80매의 영상을 준비한 후 5명의 방사선종사자가 판독 후 P(S/s), P(S/n) 구하여, ROC곡선을 그리고, 감도와 특이도 및 곡선하면적을 구해 평가하였다. 또한 AAPM(American Association of Physicists in Medicine by the American Institute of Physics)권고에 따른 ANSI chest phantom과 Contrast-detail phantom을 이용하여 non filter 또는 Cu filter사용 시 시각적으로 관찰 가능한 병소의 갯수를 파악하였으며, 또한 두 경우에서 피부입사선량을 측정하였다. 그 결과 Cu filter사용 시에 ROC곡선이 좌상방향에 위치하고, 감도, 곡선하면적 및 CD phantom 병소의 갯수에서 모두 좋은 결과를 나타내었다. 또한 피부입사선량은 감소가 되어 여러 측면에서 부가필터의 사용을 검토해 볼 필요가 있으리라 사료된다.

  • PDF

Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량 (Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis)

  • 김계선;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.347-353
    • /
    • 2015
  • 디지털 흉부단층합성법 검사에서 부가필터 사용에 따른 환자의 선량과 화질의 특성을 비교해보고자 하였다. 부가필터의 종류는 구리, 알루미늄, 니켈을 사용하였으며, 이 때 각 각의 부가필터에 따른 유효선량, 면적선량을 측정해 보았고, 화질의 물리적 평가방법으로 signal to noise ratio (SNR)과 contrast to noise ratio (CNR)을, 시각적 평가방법으로 contrast detail (CD) phantom을 이용한 CD 곡선을 비교하였다. 그 결과 부가필터별 조사선량이 비슷한 두께는 0.3 mmCu, 3 mmAl, 0.3 mmNi 였으며 부가필터를 사용하지 않았을 때 보다 조사선량 값이 평균 33.1% 감소하였다. 각 필터 별 dose area product (DAP) 선량값을 측정한 결과 Ni를 사용하였을 때 선량이 72.9% 감소하여 가장 낮았으며, 필터별 DAP 값은 통계적으로 유의한 차이를 보였다(p<0.01). 유효선량은 Ni를 사용하였을 때 가장 낮은 선량 값을 보였고, 필터를 사용하지 않았을 때 0.102 mSv에 비해 48.0% 감소하였다. CD phantom에 의한 시각적 화질평가에서는 각 필터별로 비슷한 양상을 나타냈으며, 3가지 부가필터를 사용 하였을 때 S NR과 CNR은 평균 19.07, 1 8.17% 감소함을 보였다. 결론적으로 디지털 흉부 단층합성법 검사에서 부가필터로 Ni을 사용할 경우 유효선량 및 DAP 선량 감소, 화질에서 가장 적절함을 알 수 있었다.

디지털 X선영상 평가에서 연속확신도법 ROC의 적용 (The Use of Continuous Confidence Judgments in ROC of Digital Radiography)

  • 김학성;이인자;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.147-151
    • /
    • 2009
  • ROC에 의한 의료영상을 평가하는 방법으로 지금까지는 5단계로 평가하는 평정확신도법이 일반적으로 사용되었다. 이 평정확신도법에서는 TPF나 FPF의 산출을 쉽게 구하는 것이 가능하나, 실험에 있어서 부드럽게 ROC곡선의 추정을 하기 위해서 관찰자에 대해 적당한 카테고리 배분이 요구되거나 또 짜여진 카테고리 배분을 위해 그 데이터가 무효해지는 경우가 많다. 이러한 문제를 해결하기 위해 또는 관찰실험 이외의 데이터에도 ROC해석의 응용이 가능해지도록 카테고리 분류가 되어 있지 않은 연속적으로 분포된 실험결과를 이용 ROC 해석을 행하는 방법인 연속확신도법이 보고 되었다. 하지만 국내에서는 의료영상의 평가에 연속확신도법을 적용한 예가 거의 없어서 흉부 디지털영상의 평가에 적용해 보았다. 그 결과 상용화된 프로그램에 의하여 부드러운 ROC곡선을 그릴 수 있었으며, 특성값을 쉽게 측정할 수 있어 디지털 의료영상의 평가에 적절히 사용될 수 있으리라 사료된다.

  • PDF