• 제목/요약/키워드: Contrast ratio

검색결과 1,530건 처리시간 0.036초

간 질환 감별에 있이 MR영상의 역동적 검사와 EPI의 유용성 (Value of Echo-Planar Imaging and MRI Dynamic Study in Differentiation Liver Diseases)

  • 박병래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.73-78
    • /
    • 1997
  • The goal of this paper is that we know the usefulness of echo-planar imaging(EPI) for discriminate between hepatocellular carcinoma(HCC) and hemangioma. We get a time signal intensity curve for liver diseases from the dynamic contrast enhancement images and compared and analyze both the contrast ratio(CR) and the contrast to noise ratio(CNR) using echo planar imaging. The obtained results are follows : 1. Hepatocellular carcinoma was shown the best contrast after about 20 seconds when Is the earlist time in the main artery, and then reduced. The center where is disease was shown the characteristic that the best contrast is appeared after about 35-45 seconds and then slowly reduced. Liver parenchyma was shown the best contrast and reduced after 60 seconds. 2. The peripheral nodular of hemangioma was shown the better contrast soon. On the other hend, the contrast of center where is disease started to increase after 60 seconds and was equal to that of liver parenchyma. Increasing of the contrast continued after. 3. Turbo SE technic was used, the average of CR for hepatocellular carcinoma was $36.7{\pm}1.2$ and the average of CNR was $2.4{\pm}3.2$, while the average of CNR for hemangioma was $54.9{\pm}1.0$ and the average of CNR was $9.7{\pm}1.3$. 4. EPI technic was used, the average of CR for hepatocellular carcinoma was $47.8{\pm}1.2$ and the average of CNR was $3.4{\pm}2.1$, while the average of CNR for hemangioma was $75.7{\pm}2.2$ and the average of CNR was $9.5{\pm}1.1$. According to above we can find that hemangioma is more bright than hepatocellular carcinoma and the difference of brightness between hepatocellular carcinoma and hemangioma is useful sequence.

  • PDF

고 개구율 화소보상회로를 갖는 저전력 LTPS AMOLED 패널 설계 (Design of Low Power LTPS AMOLED Panel and Pixel Compensation Circuit with High Aperture Ratio)

  • 강홍석;우두형
    • 대한전자공학회논문지SD
    • /
    • 제47권10호
    • /
    • pp.34-41
    • /
    • 2010
  • 본 연구를 통해서 대 면적, 저 전력 AMOLED 용용에 적합한 고 개구율 픽셀 보상회로와 이에 대한 구동회로를 제안하였다. 균일도는 다소 떨어지지만 안정성과 이동도가 뛰어난 저온 다결정 실리콘(LTPS) 박막 트랜지스터(TFT)를 기반으로 설계했다. 픽셀의 불량률을 낮추고 배면발광방식에 적합하도록 픽셀 보상회로를 보다 간단하게 개선하여 고 개구율 특성을 갖도록 했다. 제안하는 고 개구율 픽셀 보상회로는 일반적인 구동방식을 사용할 경우 명암비에서 큰 손해를 볼 수가 있으므로, 명암비를 높게 유지하기 위한 구동방식 및 구동회로를 제안하여 검증하였다. 이와 더불어 동영상 특성을 개선하기 위해 black data insertion 방식을 구현할 수 있도록 설계했다. 배면발광방식의 19.6" WXGA AMOLED 패널에 대해 설계했으며, 픽셀의 평균 개구율은 41.9%로 기존에 비해 8.9% 증가했다. TFT의 $V_{TH}$ 편차가 ${\pm}0.2\;V$일 때, 패널의 불균일도와 명암비는 각각 6% 이하와 10만:1 이상으로 예측되었다.

웨이브렛과 기저 계수를 이용한 X-ray 영상의 대조도 향상기법 (Contrast Enhancement for X-ray Images Based on Combined Enhancement of Scaling and Wavelet Coefficients)

  • 박천주;김도일;장도윤;윤한빈;최보영;김호경;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.150-156
    • /
    • 2008
  • 본 연구에서는 이산 웨이브렛 도메인에서 기저계수와 웨이브렛 계수의 변환을 이용하여 X-ray 이미지의 대조도를 향상시키는 방법을 제안하였다. 기저 함수의 변환은 기존에 나와있는 contrast limited adaptive histogram equalization (CLAHE)와 multi-scale image contrast amplification (MUSICA)와 같은 보편적인 영상의 대조도 향상 기법을 적용하였으며 대조도가 향상된 저해상도 기저 계수의 역변환으로 인한 Blurring 현상을 방지하고 또한 이미지의 선명도를 향상시키기 위하여 웨이브렛 계수에 sigmoid function을 적용하였다. 본 알고리즘에 대한 성능 평가를 위하여 contrast detail mammography(CDMAM) 팬텀의 영상을 획득하여 기존에 사용한 대조도 향상 기법들과 contrast to noise ratio (CNR) 및 line profile에 대한 비교평가를 실시 하였고 그 결과 기존의 대조도 향상기법을 웨이브렛 도메인에서 적용하는 것이 뛰어나다는 것을 알 수 있었다. 본 영상 대조도 향상기법은 영상의 대조도를 증가시키는 동시에 잡음의 증폭을 효율적으로 억제할 수 있다. 따라서 본 연구는 의료 영상뿐 만이 아닌 대조도와 선명도가 중요시되는 여려 분야에 적용될 수 있으리라 기대된다.

  • PDF

자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰 (The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom)

  • 이해정;이주영;임근교;박훈희
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.39-47
    • /
    • 2014
  • 유방암 환자가 매년 증가함에 따라 BSGI 검사에 대한 의존도가 높아지고 검사 건수가 증가하고 있는 추세이다. 하지만 국내에서 BSGI 검사는 각 기관의 상황 및 업체권고에 따라 검사 프로토콜을 적용하고 있으며 관련 연구가 미비한 실정이다. 그러므로 본 연구에서는 영상의 질을 평가할 수 있는 팬텀을 자체적으로 제작하여 검사 프로토콜에 대해 고찰하고자 하였다. Dilon 6800 BSGI 장비를 이용하여 팬텀 내 구의 크기는 5단계로 구분하여 제작하여 실험하였다. 방사성동위원소는 $^{99m}TcO_4$를 사용하여 배후방사능과 관심영역의 비율을 2 : 4 : 8로 구분하였으며 5, 7, 10분 영상을 획득하였다. 획득된 영상은 각 구의 크기에 따라 관심영역을 설정하고 정량적, 정성적 분석을 시행하였다. 획득된 데이터는 SPSS ver.18.0을 통해 통계 분석하였다. 정량적, 정성적 분석 결과, 방사성동위원소의 주입량에 따른 각 구의 계수율은 주입량이 많을수록 계수율이 증가하였고, 구의 크기가 클수록 계수율이 증가하는 성향을 나타냈다(p<0.005). 영상획득시간에 따른 각 구의 계수율은 획득시간이 길수록 계수율이 증가하였고, 구의 크기가 클수록 증가하는 성향을 나타냈다(p<0.005). 방사성동위원소의 주입량에 따른 각 구의 대조도 잡음비는 주입량이 많을수록 증가하는 성향을 나타냈고, 8배 비율의 획득영상에서 대조도 잡음비가 가장 높았다. 또한 영상획득시간에 따른 각 구의 대조도 잡음비는 획득시간이 길수록 증가하는 성향을 나타냈고, 7분 획득영상에서 대조도 잡음비가 가장 높았다(p<0.005). 자체적으로 제작한 팬텀을 통한 정량적, 정성적 평가에서 통계적으로 유의한 차이가 있었으며, 팬텀의 유용성을 확인할 수 있었다. 또한 본 연구를 통해 장비 특성과 환경을 고려하여 BSGI 검사 프로토콜을 확인하고 활용한다면 보다 임상적 가치가 높을 것으로 사료된다.

  • PDF

Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가 (The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish)

  • 승종민;이형진;김진의;김현주;김중현;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.58-64
    • /
    • 2011
  • SPECT 영상에서의 resolution recovery를 기반으로 하는 3D 재구성 기법은 detector면으로부터 거리에 의한 공간적 blur를 보상하여 높은 spatial resolution과 contrast를 가지는 특징이 있다. 본 논문에서는 이러한 재구성 기법 중의 하나인 Philips사의 Astonish 프로그램을 phantom 실험을 통하여 기존의 재구성 기법과 비교, 평가하고 임상적 유용성을 높이고자 하였다. Skylight SPECT system (Philips)에서 NEMA IEC PET body phantom과 Flanges Jaszczak phantom (Data Spectrum corp.)을 이용하여 시간과 거리에 따른 4가지의 다른 입력 조건에서 실험을 실시하였다. 가까운 거리와 먼 거리 (짧은 거리보다 10 cm 더해진 거리)에서 각각 full time (40 kcts/frame)과 half time (full time의 절반)을 적용하여 영상을 얻고, iteration 수에 변화를 주어 MLEM, 3D-OSEM, Astonish로 영상을 재구성하였다. NEMA IEC PET body phantom의 각 sphere에서 background variability에 따른 contrast ratio의 변화양상을 확인하고 각 재구성 기법에서의 최적의 iteration 수를 찾아보았다. 이로부터 얻은 최적의 iteration 수를 Jaszczak phantom 영상의 재구성에 적용하여 비교해보고 실제 환자의 myocardial SPECT data에 대하여 육안적 평가를 실시하였다. 전반적인 contrast ratio는 Astonish가 MLEM과 3D-OSEM보다 높았다. 직경 37 mm의 가장 큰 hot sphere에서 짧은 거리에서는 Astonish가 MLEM과 3D-OSEM보다 각각 27.1%와 17.4%의 더 높은 contrast ratio를 보였고, 먼 거리에서는 40.5%와 32.6%로 더 높았다. 그러나 시간에 따른 변화의 차이는 크게 나타나지 않았다. 또한, 육안적 평가에서 Astonish가 다른 두 재구성 기법에 비하여 더 좋은 영상을 보였다. 이 실험에서는 정량적 분석 및 육안적 평가를 통하여 Astonish가 기존의 영상 재구성 기법인 MLEM과 3D-OSEM에 비하여 시간을 단축시켜 업무의 효율성을 높일 뿐만 아니라 질적으로도 우수한 영상을 구현하여 임상적으로 신뢰성이 높은 검사 결과를 제공할 수 있음을 확인하였다.

  • PDF

Virtual Non-Contrast Computer Tomography (CT) with Spectral CT as an Alternative to Conventional Unenhanced CT in the Assessment of Gastric Cancer

  • Tian, Shi-Feng;Liu, Ai-Lian;Wang, He-Qing;Liu, Jing-Hong;Sun, Mei-Yu;Liu, Yi-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권6호
    • /
    • pp.2521-2526
    • /
    • 2015
  • Objective: The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Materials and Methods: Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Results: Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, $p{\leq}0.008$). Carcinoma-perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, p< 0.001). There were no significant differences of carcinoma-water CNR and carcinoma-perigastric fat CNR among VNCa, VNCv, and VNCe images. There was no difference in the determination of invasion or enlarged lymph nodes between normal CT and VNCa images. Conclusions: VNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

CT 조영제가 MR 조영제의 이완율에 미치는 영향 (Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium)

  • 권순용;강충환;정현근;박진서;김성호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.

The Variation of Tagging Contrast-to-Noise Ratio (CNR) of SPAMM Image by Modulation of Tagline Spacing

  • Kang, Won-Suk;Park, Byoung-Wook;Choe, Kyu-Ok;Lee, Sang-Ho;Soonil Hong;Haijo Jung;Kim, Hee-Joung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.360-362
    • /
    • 2002
  • Myocardial tagging technique such as spatial modulation of magnetization (SPAMM) allows the study of myocardial motion with high accuracy. Tagging contrast of such a tagging images can affect to the accuracy of the estimation of tag intersection in order to analyze the myocardial motion. Tagging contrast can be affected by tagline spacing. The aim of this study was to investigate the relationship between tagline spacing of SPAMM image and tagging contrast-to-noise ratio (CNR) experimentally. One healthy volunteer was undergone electrocardiographically triggered MR imaging with SPAMM-based tagging pulse sequence at a 1.5T MR scanner (Gyroscan Intera, Philips Medical System, Netherland). Horizontally modulated stripe patterns were imposed with a range from 3.6mm to 9.6mm of tagline spacing. Images of the left ventricle (LV) wall were acquired at the mid-ventricle level during cardiac cycle with FEEPI (TR/TE/FA=5.8/2.2/10). Tagging CNR for each image was calculated with a software which developed in our group. During contraction, tagging CNR was more rapidly decreased in case of short tagline spacing than in case of long tagline spacing. In the same heart phase, CNR was increased corresponding with tag line spacing. Especially, at the fully contracted heart phase, CNR was more rapidly increased than the other heart phases as a function of tagline spacing.

  • PDF

Ultrahigh Speed Reconfigurable Logic Operations Based on Single Semiconductor Optical Amplifier

  • Kaur, Sanmukh;Kaler, Rajinder-Singh
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.13-16
    • /
    • 2012
  • We demonstrate an optical gate architecture using a single SOA to perform AND, OR and NOT logic functions. Simple reconfigurable all-optical logic operations are implemented using RZ modulated signals at 40 Gb/s. Contrast ratio and extinction ratio values have been analysed for the different types of logic gates. Maximum extinction ratio and contrast ratio achieved are 19dB and 17.2 dB respectively. Simple structure and potential for integration makes this architecture an interesting approach in photonic computing and optical signal processing.

치마$\cdot$저고리의 색상 면적비 변화에 따른 한$\cdot$미 여대생의 조화감 비교 연구 - 유사배색과 대비배색을 중심으로 - (The Comparative Study of the Harmony of Coloration according to Transformation of Color Area-Ratio in Traditional Korean Dress of Korean and American Students - On the similarity and contrast coloration -)

  • 강경자;문주영;임지영
    • 한국의상디자인학회지
    • /
    • 제7권3호
    • /
    • pp.17-26
    • /
    • 2005
  • In this research, in order to find out the effect of the area ratio in the harmonic sense assessment of the coloration of Korean clothes, the coloration of a Korean jacket and a skirt was compounded with a similar coloration and a contrast coloration. The respondents were asked to evaluate 16 stimuli of the traditional Korean skirt and jacket with the coloration of the Korean jacket/ skirt, the skirt/ Korean jacket was separately compounded to be 4 tones such as vivid, light, dull, dark. The subjects were 44 female undergraduate students. The results of each can be summerized as follows. As to similar coloration, the korean yellow jacket and red skirt, Korean students feel vivid and dull tone was harmonious, and American students feel vivid, light, and dark tone were harmonious coloration. In inversed case, red korean jacket and yellow skirt, both countries' students recognized that the vivid tone was harmonious. Korean students gave higher points to korean traditional dress in similar coloration such as yellow korean jacket which was small area and red skirt which was large area coloration than inversed color area ratio which red korean jacket and yellow skirt. As to contrast coloration, the korean green jacket and red skirt, Korean students feel vivid tone was harmonious, and American students feel vivid, dark tone were harmonious coloration. In inversed case, red korean jacket and green skirt were recognized that any tone was not harmonious for both countries' students. Both countries of student showed the culture gap. Compared with American students, Korean students were familiar with korean dress's traditional coloration, as a result familiar coloration was recognized harmonious coloration.

  • PDF