• Title/Summary/Keyword: Contrast effect

Search Result 2,796, Processing Time 0.033 seconds

Quantitative Comparison of 1H-MRS Spectra Depending on the Paramagnetic Gadolinium Contrast Agent(GBCA) Injection (가돌리늄 조영제 주입에 따른 1H-MRS spectrum의 정량적 비교)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.589-595
    • /
    • 2017
  • This study evaluated the effect of gadolinium contrast agents on the spectrum of metabolites during $^1H-MRS$ of brain and to investigate whether the contrast agents injected before MR spectroscopy significantly affect the estimated peaks of MRS. From January to May 2017, brain MR spectroscopy was performed on 30 patients to compare the spectrum before and after contrast injection of the brain white matter tissue. As a result, the spectrum of metabolites decreased after the paramagnetic contrast agents injected. However, it was not statistically significant which indicated that the use of contrast agent did not meaningfully affect the spectrum of metabolites. In conclusion, the use of the paramagnetic contrast before the acquisition of the spectroscopy may aid voxel positioning especially when it is difficult to determine the exact location of the lesion or the contrast is low.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

The Clothing Image according to Coloration, Tone, and Interval of Checked Pattern in Color Contrast (색상대비 체크무늬의 배색, 톤, 간격에 따른 의복이미지)

  • Jeong, Su-Jin;Choi, Su-Koung
    • Fashion & Textile Research Journal
    • /
    • v.13 no.2
    • /
    • pp.147-154
    • /
    • 2011
  • The purpose of this study was to investigate the clothing image according to coloration, tone, and interval of checked pattern in color contrast. The experimental materials developed for this study were a set of stimulus and response scales. The stimuli were 24 color pictures, in which coloration(RB: Red+Blue, YP: Yellow+Purple), tone(light, dull, dark), and interval(0.5 cm, 1.5 cm, 3.5 cm, 5.5 cm) were manipulated. The 7-point scale was used for evaluation of clothing image. Data were obtained from 240 female college students living in Seoul, Gwangju, Jinju, and Masan on May 2010. For data analysis, ANOVA and Duncan-test were used by using SPSS program. Results of this study were as follows.; Clothing image according to coloration, tone, and interval of checked pattern consisted of five dimensions of attractiveness, freshness, appeal, modesty, and activity. Coloration showed an independent effect on attractiveness and appeal. Tone showed an independent effect on freshness, appeal, and modesty. Interval showed an independent effect on freshness. Also, interaction effects of coloration and tone on appeal were found. Interaction effects of coloration and interval on modesty were found.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

A Study on the Change of Contrast Sensitivity with Breath Alcohol Concentration in Various Luminance (다양한 휘도에서 호흡 알코올 농도에 따른 대비감도 변화 연구)

  • Nam, Soo-Kyung;Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.505-511
    • /
    • 2014
  • Purpose: This study was to investigate the effect of breath alcohol concentration (BrAC) increase with drinking alcohol on contrast sensitivity in the conditions of restricted BrAC. Methods: 23 males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected and administered the amount of alcohol to reach 0.05% and 0.08% BrAC calculated by BAC (blood alcohol concentration) Dosing Software program, which was developed as basis of Watson's formula. Then, the contrast sensitivity in various luminance conditions (photopic, mesopic, and mesopic with glare) was measured and compared between these conditions. Results: The contrast sensitivity in all spatial frequency was decreased with BrAC increase. Although BrAC was increased, the peak of contrast sensitivity didn't change as 6 cycle per degree (cpd) in the photopic condition and 3 cpd in the mesopic condition, respectively. But, in the mesopic condition with glare, the peak of contrast sensitivity was shifted from 6 cpd at 0% and 0.05% BrAC to 3 cpd at 0.08% BrAC with increase of alcohol concentration. Conclusions: The increase of BrAC by drinking alcohol induces the decrease of contrast sensitivity in all spatial frequency and the shift of peak of contrast sensitivity, which can cause safety accidents, and may have an effect on various visual tasks.

Effects of Transmittance of Diffusive Blur on Visual Acuity and Contrast Sensitivity (확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향)

  • Yang, Seok-Jun;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.355-362
    • /
    • 2015
  • Purpose: To investigate the effects of the transmittance of diffusive blurson visual acuity and contrast sensitivity. Methods: Visual acuity and contrast sensitivity were measured by using Optec$^{(R)}$ 6500 in Healthy 30 subjects aged $22.83{\pm}0.50$ (male 13, female 17) who were recruited from university students. Cataract simulator was used as a tool for diffusive blur. Visual acuity and contrast sensitivity were measured with varying the transmittance of diffusive blur in order to simulate progression of cataract and concentration in fog. Results: Visual acuity was reduced proportionally with decreasing the transmittance of the diffusive blur as follows: $VA(T)=1.84{\times}10^{-2}T-0.645$. Contrast sensitivity was decreased in all spatial frequencies. Contrast sensitivity in a high spatial frequency band was a greater effect and was off the normal range of contrast sensitivity. The peak of contrast sensitivity was moved in the direction to low frequency. From an intersection point of contrast sensitivity function, we could calculated the transmittance of the diffusive blur being off the normal range and the shift to peak spatial frequency. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd at transmittance of about 78.70%, the contrast sensitivities for all frequencies at transmittance of about 69.71% were deviated from the normal range. Conclusions: The transmittance of diffusive blur causes a reduction in visual acuity and contrast sensitivity, a deviation of normal range of contrast sensitivity, and a shift of peak contrast sensitivity. Therefore the more attention is required when suffering from cataracts or driving in fog.

A decision support system the interface between PACS and Laboratory Information (PACS 와 임상검사정보의 연동으로 인한 의사결정시스템; 크레아틴 수치정보전송으로 인한 조영제 부작용 예방)

  • Kim, Sean-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.17-19
    • /
    • 2007
  • This study applies in case of operating an exam using by the contrast order or inputting an order of a contrast media the exam of Radiology Department. It is developed for helping decision making as regards a process of an exam from reading the creatinine value automatically linked with Laboratory Information System. It can be confirmed by real-time information; therefore, the creditability of the information is able to be improved. We will create the base for Patient Monitoring System with the data from the side effect of the creatinine value and allergies. Decision Support System minimize the inconvenience and the riskiness of the given contrast medium for CT tests. We would like to improve medical services by providing a standard circumstance where patients are able to run tests safely and comfortably.

  • PDF

Spatial Luminance Contrast Sensitivity: Effects of Surround

  • Kim, Youn-Jin;Kim, Hong-Suk
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.152-162
    • /
    • 2010
  • This study examined the effects of surround luminance on the shape of the spatial luminance contrast sensitivity function (CSF). The reduction in brightness of uniform neutral patches shown on a computer controlled display screen is also assessed to explain the change of CSF shape. Consequently, a large amount of reduction in contrast sensitivity at middle spatial frequencies can be observed; however, the reduction is relatively small for low spatial frequencies. In general, the effect of surround luminance on the CSF appears similar to that of mean luminance. Reduced CSF responses result in less power of the filtered image; therefore, the stimulus should appear dimmer with a higher surround luminance.

Measurement of Flow Velocity and Flow Visualization with MR PC Image (MR PC 영상을 이용한 유체 흐름 분석)

  • Kim, S.J.;Lee, D.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF

Estimation of Flaw Depth and Height by Radiography (방사선투과사진에 의한 결함깊이 및 높이의 평가)

  • Kang, Kae-Myung;Park, Un-Su;Sim, Eon-Deok
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.682-687
    • /
    • 2002
  • The three-dimensional estimation on the depth and height of flaw by using the difference of radiographic contrast density was studied. First, the specimens having artificial flaws of various depths and heights were prepared and the radiographic testing was performed. The radiographic depth of flaw was investigated and estimated on the effect of the scattered radiation with the change of distance between flaw and film. The height of flaw was estimated from the radiographic test with the reference specimen. The radiographic contrast with flaw depth decreased with increasing the flaw depth. The scattered radiation increased with increasing flaw depth and varied with the location between flaw and film. However, in the case of flaw height, the contrast density increased with increasing flaw height. It is thought due to the change in volume generating the scattered radiation which reaches a film.