• Title/Summary/Keyword: Contrast Analysis

Search Result 3,295, Processing Time 0.033 seconds

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

Optimal Conditions for Defect Analysis Using Electron Channeling Contrast Imaging

  • Oh, Jin-Su;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.46 no.3
    • /
    • pp.164-166
    • /
    • 2016
  • Electron channeling contrast imaging (ECCI) is a powerful analyzing tool for identifying lattice defects like dislocations and twin boundaries. By using diffraction-based scanning electron microscopy technique, it enables microstructure analysis, which is comparable to that obtained by transmission electron microscopy that is mostly used in defect analysis. In this report, the optimal conditions for investigating crystal defects are suggested. We could obtain the best ECCI images when both acceleration voltage and probe current are high (30 kV and 20 nA). Also, shortening the working distance (6 mm) enhances the quality of defect imaging.

An Adaptive Histogram Equalization Based Local Technique for Contrast Preserving Image Enhancement

  • Lee, Joonwhoan;Pant, Suresh Raj;Lee, Hee-Sin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.35-44
    • /
    • 2015
  • The main purpose of image enhancement is to improve certain characteristics of an image to improve its visual quality. This paper proposes a method for image contrast enhancement that can be applied to both medical and natural images. The proposed algorithm is designed to achieve contrast enhancement while also preserving the local image details. To achieve this, the proposed method combines local image contrast preserving dynamic range compression and contrast limited adaptive histogram equalization (CLAHE). Global gain parameters for contrast enhancement are inadequate for preserving local image details. Therefore, in the proposed method, in order to preserve local image details, local contrast enhancement at any pixel position is performed based on the corresponding local gain parameter, which is calculated according to the current pixel neighborhood edge density. Different image quality measures are used for evaluating the performance of the proposed method. Experimental results show that the proposed method provides more information about the image details, which can help facilitate further image analysis.

An Analysis of Pattern of Transforaminal Epidurography (경추간공 경막외 조영술의 양상에 관한 분석)

  • Hong, Ji Hee
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.175-180
    • /
    • 2006
  • Background: A transforaminal epidural steroid injection has been used for the treatment of radicular arm or leg pain, which has the advantage of ventral epidural spreading compared to either an interlaminar or caudal approach. However, several factors are known to affect the epidural spread pattern of contrast dye; therefore, the injected medication can not be delivered to the target site. The objective of our study was to observe any differences in the contrast flow patterns according to several factors. Methods: A total of 34 epidurographies in 29 patients, who underwent fluoroscopically guided transforaminal epidural steroid injections, were evaluated. After confirming the location of the needle tip within the anterior superior aspect of the neural foramen in the lateral view, and at the 6 o'clock position to the pedicle in the anteroposterior view, 2 ml of contrast dye was injected. The contrast flow patterns of ventral, ventral and dorsal, and dorsal epidural filling were analyzed, according to age, gender, magnetic resonance imaging finding and history of previous back surgery. Results: Ventral contrast flow occurred in 30 out of the 34 epidurographies (88%). Both ventral and dorsal contrast flow patterns were observed 13 out of 16 (81%) patients in the older age group. Also, both ventral and dorsal contrast flow patterns were observed in 16 out of 18 (88%) patients with spinal stenosis. Conclusions: Transforaminal epidural steroid injections, performed uner fluoroscopy, provide excellent nerve root filling and ventral epidural spreading. Patients with spinal stenosis or an old age have both ventral and dorsal epidural spreading patterns.

Generation of contrast enhanced computed tomography image using deep learning network

  • Woo, Sang-Keun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 2019
  • In this paper, we propose a application of conditional generative adversarial network (cGAN) for generation of contrast enhanced computed tomography (CT) image. Two types of CT data which were the enhanced and non-enhanced were used and applied by the histogram equalization for adjusting image intensities. In order to validate the generation of contrast enhanced CT data, the structural similarity index measurement (SSIM) was performed. Prepared generated contrast CT data were analyzed the statistical analysis using paired sample t-test. In order to apply the optimized algorithm for the lymph node cancer, they were calculated by short to long axis ratio (S/L) method. In the case of the model trained with CT data and their histogram equalized SSIM were $0.905{\pm}0.048$ and $0.908{\pm}0.047$. The tumor S/L of generated contrast enhanced CT data were validated similar to the ground truth when they were compared to scanned contrast enhanced CT data. It is expected that advantages of Generated contrast enhanced CT data based on deep learning are a cost-effective and less radiation exposure as well as further anatomical information with non-enhanced CT data.

A Clinical Study on the Ordinary Sleeping Patterns of Soyangin (소양인(少陽人) 수면 습관에 관한 연구)

  • Kim, Jung-Ju;Lee, Yung-Seop;Park, Seong-Sik
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.65-72
    • /
    • 2005
  • Objectives : This study is for discovering the clinical Features of the sleep in ordinary symptoms based on the Sasang Constitution. The result of this study could be helpful to understand and to identify the patients as Soyangin in contrast with the other constitutions -Soeumin, Taeumin and Taeyangin. Methods : There were 1,229 patients(700 female), who answered the questionnaire about their ordinary sleeping patterns. They had been diagnosed, including their clinical Sasang Constitution, by the Sasang Constitution specialist at Bundang Oriental Hospital of Dongguk University. By applying the binary logistic regression analysis, we can measure the characteristics and the influence of ordinary sleeping patterns to the dependent variable(Sasang Constitution). Results : As a result of the binary logistic analysis on the observed questionnaire, we found the characteristics of the ordinary sleeping patterns on Soyangin in contrast with the other constitutions. Firstly, Soyangin has a tendency that he wouldn't dreams more, when he sleeps in contrast with the others. Secondly, Soyangin has a tendency that he wouldn't sleep longer than 6-7hours. Thirthly, Soyangin has a tendency that he will sleep well in contrast with the others. Conclusion : This study will be used to identify patients as Soyangin in contrast with the others-Soemin, Taeumin and Taeyangin.

  • PDF

Contrast Enhancement Method for Images from Visual Sensors (비주얼 센서 영상에 대한 대비 개선 방법)

  • Park, Sang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.525-532
    • /
    • 2018
  • Recently, due to the advancements of sensor network technologies and camera technologies, there are increasing needs to effectively monitor the environment in a region that is difficult to access by using the visual sensor network that combines these two technologies. Since the image captured by the visual sensor reflects the natural phenomenon as it is, the quality of the image may deteriorate depending on the weather or time. In this paper, we propose an algorithm to improve the contrast of images using the characteristics of images obtained from visual sensors. In the proposed method, we first set the region of interest and then analyzes the change of the color value of the region of interest according to the brightness value of the image. The contrast of an image is improved by using the high contrast image of the same object and the analysis information. It is shown by experimental results that the proposed method improves the contrast of an image by restoring the color components of the low contrast image simply and accurately.

A Comparative Analysis Study on Distance Contrast Sensitivities According to Progressive Lens Design (누진렌즈 디자인에 따른 원거리 대비감도 비교분석 연구)

  • Shin, Dong-Min;Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.241-246
    • /
    • 2013
  • Purpose: The aim of this study was a comparative analysis of the effect of distance contrast sensitivity when wearing free-form progressive lens and conventional progressive lens. Methods: The 20 subjects who do not have any ocular diseases were participated in this study. Contrast sensitivities at 5 different levels of spatial frequency were conducted by using FACT (Stereo Optical, USA). Results: Contrast sensitivity was measured for free-form progressive lens and conventional progressive lens in the order of right eye, left eye and binocular. Right/left/binocular contrast sensitivity values of the free-form progressive lenses compared to the conventional progressive lenses were higher 16%/17%/11% at A(1.5 cpd) of spatial frequency, 11%/5%/5% at B(3 cpd) of spatial frequency, 6%/6%/9% at C(6 cpd) of spatial frequency, 19%/16%/13% at D(12 cpd) of spatial frequency, 4%/3%/18% at E(18 cpd) of spatial frequency. Conclusions: In all the area of spatial frequency, distance contrast sensitivity values were measured highly on free-form progressive lens than on conventional progressive lens.

Image Analysis of Micro Lesions According to Grid Frequency After Removal of Moire Artifact (Moire artifact 제거 후 그리드 주파수에 따른 미세병변의 영상분석)

  • Lee, Sang-Ho;Kim, Gyoo-Hyung;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • Morphological information such as shape and margin of micro lesion is important information for diagnosis of disease in clinical imaging. In this study, we investigated the morphological changes of the micro lesions by comparing the contrast and area in grid suppressed DR images according to grid frequency. In the profile analysis of the image, the mass showed an average intensity variation of 8.6 ~ 72.4 after suppression, The higher the grid frequency, the more the contrast was increased. However, in the images obtained using 103 lp / inch, which is a grid frequency less than the sampling frequency, the contrast of the mass in the vertical direction decreased after suppression. In the binary image, the area change of the mass was also large. As a result, the shape, size, and margin of the mass changed. In the case of very small calcification, the higher the grid frequency is the larger the change in contrast, so that a clear image can be obtained in the post-suppression image. However, we could confirm that the margin of the lesion was blurred and the lesion was lost in some of the images using the 103 lp / inch grid. The higher the frequency of the grid, The change of the contrast of fiber occurred largely and clear boundary was confirmed. The decrease of the number of pixels was small and morphological change was small. In conclusion, when using a grid frequency that is not suitable for the sample frequency, morphological changes or lesion loss of micro lesions in the post- suppression image may give the possibility of misdiagnosis in diagnosis and differentiation of the image.

Preliminary study on contrast flow analysis of thoracic transforaminal epidural block

  • Hong, Ji Hee;Noh, Kyoung Min;Park, Ki Bum
    • The Korean Journal of Pain
    • /
    • v.31 no.2
    • /
    • pp.125-131
    • /
    • 2018
  • Background: The thoracic transforaminal epidural block (TTFEB) is usually performed to treat herpes zoster or postherpetic neuralgia (PHN). Especially, multiple segmental involvements and approximate contrast medium spread range, according to volume, help to choose the proper drug volume in the transforaminal epidural block. This study investigated the contrast medium spread patterns of 1-ml to 3-ml TTFEBs. Methods: A total of 26 patients with herpes zoster or PHN were enrolled in this study. All participants received 1 ml, 2 ml, or 3 ml of contrast medium. Results were divided into Groups A, B and C based on the volume (1, 2, or 3 ml), with n = 26 for each group. After the injection of contrast medium, the spread levels were estimated in both the lateral and anteroposterior (AP) images using fluoroscopy. Results: The cephalad spread of contrast medium in the lateral image as expressed by the median (interquartile range) was 2.00 levels (1.00-2.00) for Group A, 2.50 (2.00-3.00) for Group B, and 3.00 (2.00-4.00) for Group C. The caudal spread level of contrast medium was 1.00 (1.00-2.00) for Group A, 2.00 (2.00-3.00) for Group B, and 2.00 (2.00-3.00) for Group C. There was ventral and dorsal spread of the 3-ml contrast medium injection in 88% (23/26) of cases in the lateral image. Conclusions: Injection of 3 ml of contrast medium through the foramina spread 6 levels in a cephalocaudal direction. Spread patterns revealed a cephalad preference. TTFEB resulted in dorsal and ventral spread in a high percentage of cases. This procedure may be useful for transferring drugs to the dorsal and ventral roots.