• Title/Summary/Keyword: Contrast - to - Noise Ratio

Search Result 298, Processing Time 0.03 seconds

Mura 검출을 위한 Model Fitting 및 Least Square Estimator의 비교 (Comparison of Model Fitting & Least Square Estimator for Detecting Mura)

  • 오창환;주효남;류근호
    • 제어로봇시스템학회논문지
    • /
    • 제14권5호
    • /
    • pp.415-419
    • /
    • 2008
  • Detecting and correcting defects on LCD glasses early in the manufacturing process becomes important for panel makers to reduce the manufacturing costs and to improve productivity. Many attempts have been made and were successfully applied to detect and identify simple defects such as scratches, dents, and foreign objects on glasses. However, it is still difficult to robustly detect low-contrast defect region, called Mura or blemish area on glasses. Typically, these defect areas are roughly defined as relatively large, several millimeters of diameter, and relatively dark and/or bright region of low Signal-to-Noise Ratio (SNR) against background of low-frequency signal. The aim of this article is to present a robust algorithm to segment these blemish defects. Early 90's, a highly robust estimator, known as the Model-Fitting (MF) estimator was developed by X. Zhuang et. al. and have been successfully used in many computer vision application. Compared to the conventional Least-Square (LS) estimator the MF estimator can successfully estimate model parameters from a dataset of contaminated Gaussian mixture. Such a noise model is defined as a regular white Gaussian noise model with probability $1-\varepsilon$ plus an outlier process with probability $varepsilon$. In the sense of robust estimation, the blemish defect in images can be considered as being a group of outliers in the process of estimating image background model parameters. The algorithm developed in this paper uses a modified MF estimator to robustly estimate the background model and as a by-product to segment the blemish defects, the outliers.

퍼지적분을 이용한 영상품질의 객관적이고 정량적 평가: 팬톰 연구 (Objective and Quantitative Evaluation of Image Quality Using Fuzzy Integral: Phantom Study)

  • 김성현;서태석;최보영;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.201-208
    • /
    • 2008
  • 물리적 평가(physical evaluation)가 영상품질의 객관화와 정량화를 위한 토대를 제공함에도 불구하고, 부정확하고 가변적인 특성을 지닌 주관적 평가(subjective evaluation)가 영상평가에 중요한 역할을 하게 된다. 본 연구에서는 디지털 방사선 영상의 물리적 평가와 주간적 평가의 단점을 상호 보완하고 객관적 정량화를 위한 새로운 방법을 제안하고자 한다. 임상에 사용되고 있는 4대의 디지털 방사선 영상 촬영장치로부터 동일한 임상조건에서 흉부 팬톰 영상을 획득하였다. 물리적 영상평가를 위하여 디지털 흉부 팬톰 내에서 3개의 영역(폐, 심장, 그리고 복부)에 존재하는 CNR (contrast-to-noise ratio)를 측정하였고 분할(segmentation)과 정합(registration)등 다양한 영상처리기술이 적용되었다. 주관적 평가는 5명의 관찰자에 의한 저 대조도 물체의 식별 정도를 점수화 하였다. 두 평가의 특성을 보완 및 결합하고자 퍼지적분 이론이 도입되었다. 4대의 시스템으로부터의 평가결과가 비교되었으며, 물리적 평가와 주관적 평가가 항상 비례하지 않음을 보였다. 물리적 평가에서는 높은 점수를 보였던 시스템이 주관적 평가에서는 상대적으로 낮은 평가를 보였다. 본 연구에서 제안한 퍼지적분에 의한 영상평가의 정량화는 물리적 평가와 주관적 평가를 모두 포함하는 총체적인 평가 방법이며, 다양한 영상품질 평가에 유용할 것이라 사료된다.

  • PDF

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

맘모패드의 새로운 재질에 관한 평가 (Evaluation of New Material Mammopad)

  • 문영주;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.265-270
    • /
    • 2019
  • Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구 (Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography)

  • 김기원;권용락;서승원;권경태;오주영;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.205-211
    • /
    • 2015
  • 복부 전후 방향 검사 시 automatic exposure control (AEC) mode에서 조사시간을 제한하지 않고 검사를 하는 방법 (non-time limit, NTL) 과 조사시간을 제한하고 검사하는 방법 (time limit, TL)에 대해서 영상 품질 평가인 신호 대 잡음비 (signal to noise ratio, SNR), 대조도 대 잡음비 (contrast to ratio, CNR)를 측정하여 TL 방법과 NTL방법을 비교 평가하고자 하였다. 실험 기기는 XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden), Rando Phantom (alderson research laboratories, USA)과 $5.5{\times}9{\times}0.1cm^3$ 크기의 차폐재를 사용하였으며, AEC mode에서 전리함 (ionization chamber)를 상단 2 개만 작동하도록 설정하고 관전압은 80 kVp로 설정하였다. TL 방법의 경우에는 조사시간을 51 msec로 제한하였으며, 전리함에 차폐재를 부착하지 않은 상태와 부착한 상태에서 NTL AEC mode와 TL AEC mode의 영상을 획득하였다. 또한 'Image J"를 이용하여 영상 평가방법인 SNR과 CNR로 평가하였다. 결론적으로 차폐재를 부착했을 때 NTL AEC mode가 다른 실험 방법보다 선량이 최대 130.7% 최소 80%까지 증가한 결과 값을 보였으며, TL AEC mode는 NTL AEC mode보다 mAs와 피폭선량에서 각 각 43.8%, 44.4% 감소한 값을 보였다. 통계적으로는 SNR과 CNR은 유의한 차이를 보이지 않았다($p{\geq}0.05$). 그러므로, 본 연구에서는 BMI 지수가 높은 환자나 수술 후 인체 내에 금속물질이 있는 환자를 검사할 경우에는 TL AEC mode가 유효한 검사법이라고 사료된다.

재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가 (Comparison of PET/MR image quality with and without point spread function algorithm according to reconstruction type)

  • 박찬록;문일상;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.43-45
    • /
    • 2018
  • NEMA IEC body phantom으로 PET/MR 스캐너를 이용해 MR 영상 기반의 감쇠보정 된 PET 영상을 얻고, 반복재구성 기반의 점 확산 함수(PSF)에 적용 유무에 따라 PET 영상을 Contrast recovery 와 SNR 의 평가 인자를 적용해 평가하였다. 또한, 동일한 재구성 방법에 따라 본원의 내원한 환자의 영상도 평가하였다. 데이터는 임상환자 와 팬텀 실험 모두 PSF를 적용해 재구성한 영상이 모두 영상의 질이 향상됨을 확인하였다. MR 기반으로 얻어진 PET 영상 평가가 추후에도 계속해서 필요하다고 사료된다.

간 초음파 영상에서의 스페클 노이즈 제거를 위한 필터들의 비교 평가 (Comparative Evaluation of Filters for Speckle Noise Reduction in a Clinical Liver Ultrasound Image)

  • 김하진;이영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.475-484
    • /
    • 2023
  • This study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the filter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.

모바일 TFT-LCD 구동 집적회로를 위한 화질 레지스터 최적화시스템 개발 (Development of Image Quality Register Optimization System for Mobile TFT-LCD Driver IC)

  • 류지열;노석호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 추계종합학술대회 B
    • /
    • pp.592-595
    • /
    • 2008
  • 본 논문은 모바일 TFT-LCD 구동 집 회로와 임베디드 소프트웨어를 이용한 자동 화질 레지스터 최적화시스템을 제안한다. 이러한 시스템은 LCD모듈의 중요한 화질 평가 요소인 평균 감마 오차, 감마 조정 시간, 플리커 잡음 및 명암비 등을 최적화하기 위해 모바일 LCD구동 집적회로 내의 감마조정 레지스터들과 전압 설정 레지스터 들을 자동적으로 제어한다. 개발된 알고리즘과 임베디드 소프트웨어는 거의 모든 유형의 LCD모듈에 적용 가능하다. 개발된 화질 최적화 시스템은 측정 대상이 되는 모듈 (MUT, LCD 모듈), 제어 프로그램, 휘도 측정용 멀티미디어 디스플레이 측정기 및 인터페이스용 제어 보드로 구성되어 있다. 제어 보드는 DSP와 FPGA로 구성 되 어 있고, RGB 및 CPU 인터페이스를 지원한다.

  • PDF

Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구 (Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change)

  • 조유진;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.107-114
    • /
    • 2015
  • 간 역동적 CT(Liver Dynamic Computed Tomography; LDCT) 검사에서 일반적으로 사용하는 프로토콜과 관전압을 낮게 설정한 후 프로토콜을 변화시켰을 때 방사선량과 영상의 질을 비교하여 영상의 질을 유지하면서 방사선량을 감소시킬 수 있는 방안을 알아보고자 하였다. LDCT를 시행한 환자 중 신체질량지수(body mass index; BMI)가 18.5~24인 환자 40명을 대상으로 일반적인 복부 CT 검사 프로토콜을 적용한 A그룹 20명(관전압: 120 kVp, SAFIRE strength1)과 관전압을 낮게 설정한 B그룹 20명(관전압: 100 kVp, SAFIRE strength 0~5 적용)이었다. 영상의 질 평가는 동맥기의 간 실질 조직, 대동맥, 상장간막동맥, 복강동맥, 내장지방 그리고 백그라운드에 관심영역(region of interest; ROI)을 설정해 잡음(noise), 신호대 잡음비(signal to noise ratio; SNR), 대조도 대 잡음비(contrast to noise ratio; CNR), CT number를 측정 비교하였다. 또한 정성적 평가는 경험이 풍부한 영상의학과 전문의 2명이 0~3점까지로 평가하였다. 방사선량은 총 DLP(dose length product)와 유효선량, CTDIvol(volume computed tomography dose index)을 비교하였다. 관전압 100 kVp에서 SAFIRE가 높을수록 잡음은 감소하고, CT number는 증가하였다. 따라서 SNR과 CNR은 SAFIRE 단계가 높을수록 증가하였다. 관전압 120 kVp와 비교하여 잡음, SNR, CNR이 SAFIRE strength 2, 3에서 가장 유사하였다. 정성적 평가는 SAFIRE strength 2가 가장 많았고 관전압이 100 kVp일 때 영상의 질이 더 좋다고 평가한 경우는 SAFIRE 1이었다. 방사선량은 120 kVp에 비해 100 kVp에서 21.69% 감소하였다. BMI가 비교적 높지 않은 LDCT 검사의 경우 공장에서 출고될 당시에 관전압이 높게 설정되어 있어 불필요한 방사선피폭이 우려되고 있는 현실을 고려하면, 본 연구 결과에 따라 관전압을 낮게 설정하고 SAFIRE strength를 2로 조정하면 영상의 질 저하 없이 방사선량도 감소시킬 수 있을 것으로 사료된다.