• Title/Summary/Keyword: Contraction stress

Search Result 200, Processing Time 0.022 seconds

EFFECT OF INCREMENTAL FILLING TECHNIQUE ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (적층충전법이 복합레진의 중합수축에 미치는 영향)

  • Kim, Hyo-Suk;Lee, Nan-Young;Lee, Sang-Ho;Oh, You-Hyang
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.481-490
    • /
    • 2005
  • The aim of this study was to investigate the relationship between the C-factor and shrinkage strain values of composite resin and examine the strain values in different incremental filling techniques. The strain gauge method was used for measurement of polymerization shrinkge strain. Experiment was divided two step. In a first experiment, we compared with strain value in three different depth (2mm, 3mm, 4mm) and microhardness of each samples after 24hours were measured. In a second experiment, we examined the strain values in five different filling techniques(Group 1: bulk filling, Group 2: oblique incremental filling, Group 3: horizontal incremental filling, Group 4: vertical incremental filling, Group 5: lining of flowable resin and bulk filling) The results of the present study can be summarized as follows: 1. Composite resin in acrylic molds showed the initial expansion at the early phase of polymerization. 2. Contraction stress was not revealed significant difference between depth of 2mm and 3mm(P>0.05). 3. Contraction stress in sample of 4mm was showed the lowest value(P<0.05). 4. Microhardness of specimen was revealed more difference between upper and lower surface in depth of 4mm than 2 and 3mm(P<0.05). 5. Lining of flowable resin and bulk filling (Group 5) was showed the lowest contraction stress, Group 2 and 3 was showed the highest contraction stress(P<0.05). On the basis above results, the stress that result from the polymerization shrinkage, when incremental curing techniques are used, showed that there is no advantage in incremental placement and curing.

  • PDF

Analysis of cavity expansion and contraction in unsaturated residual soils

  • Lukosea, Alpha;Thiyyakkandi, Sudheesh
    • Geomechanics and Engineering
    • /
    • v.28 no.4
    • /
    • pp.405-419
    • /
    • 2022
  • Cavity expansion and contraction solutions for cylindrical and spherical cavities in unsaturated residual soils are presented in this paper. Varying soil state in the plastic zone is accounted by a numerical approach, wherein an element-by-element discretization of the plastic zone of both expanding and contracting cavities is carried out. Unlike existing methods utilizing self-similarity technique, the solution procedure enables the prediction of entire soil-state at any stage of expansion and subsequent contraction. It is also applicable for both cavity creation and expansion problems. The approach adopts constant contribution of suction to effective stress (constant Xs drainage condition) for analysis. The analysis procedure is validated by interpreting the previously reported pressuremeter test results in lateritic residual soil. The typical cavity expansion and contraction characteristics of unsaturated Indian lateritic soil were then examined using this solution procedure. The effect of initial soil-state on cavity limit pressure, plastic radius, reverse yield pressure, and reverse plastic radius are also presented.

The Effects of Psychological Stress on Neck Muscles (정신적 스트레스가 경항부 근육에 미치는 영향)

  • Kwon, Ho-Young;Kim, Jeong-Hwan
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.1
    • /
    • pp.119-132
    • /
    • 2010
  • Objectives : The purpose of this study is to compare interrelations between stress and muscles of neck through stress response inventory(SRI), 7 zone diagnostic system and surface electromyography(sEMG). Methods : This study was carried out with the data from SRI, 7 zone diagnostic system and sEMG. First subjects were divided into two group according to the SRI points. subjects in group A had points of SRI in which lower than 30 points. Subjects in group B had points of SRI in which higher than 30 points. And subjects were divided into nonstress group(Group C) and stress grouop(Group D) according to the result of 7 zone diagnostic system. Then we investigated how to differentiate the muscle contraction, fatigue, recovery and asymmetry ratio on sEMG for each groups. Results : In this study, the muscle contraction of both upper trapezius muscle and left sternocleidomastoid muscle and left scalene muscle in stress group were higher than nonstress group significantly. And the muscle recovery of left sternocleidomastoid muscle and left scalene muscle in stress group were higher than nonstress group significantly. Conclusions : This results show that the stress was associated with muscle condition.

Quantitative Evaluation of the Stress Urinary Incontinence using the Contraction pressure measurement at the Pelvic Floor Muscle (골반저근의 수축압력 측정을 이용한 복압성요실금의 정량적 평가)

  • Min, H.K.;Noh, S.C.;Kwon, J.W.;Min, K.S.;Choi, H.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.13-19
    • /
    • 2007
  • In this study, diagnostic algorithm was suggested to diagnose quantitatively the degree of the stress urinary incontinence. The bio-signal measurement system was developed to measure the contraction pressure of the pelvic floor muscle and diagnostic parameters were drawn out by analyzing the contraction pressure data. Statistical evaluations were done to classify the diagnositc parameters by order that relationship is high. The diagnostic algorithm that was able to diagnose degree of the urinary incontinence as quantitatively was realized from the high relationship parameters.

  • PDF

EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT (LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향)

  • Chung, Yang-Seok;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.623-631
    • /
    • 2007
  • Effect of Soft-start curing on the contraction stress of composite resin restoration polymerized with LED and plasma curing unit The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin (Filtek $Z-250^{TM}$, 3M ESPE, USA) was cured using the one-step continuous curing method with three difference light sources ; conventional halogen light ($XL3000^{TM}$, 3M ESPE, USA) cure for 40 seconds at $400 mw/cm^2$, LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure for 20 seconds at $800\;mW/cm^2$ a and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure for 12 seconds at $1300 mW/cm^2$. For the soft-start curing method ; LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure exponential increase with 5 seconds followed by 17 seconds at $800\;mW/cm^2$ and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure 2 seconds light exposure at $650\;mW/cm^2$ followed by 11 seconds at $1300\;mW/cm^2$. The strain guage method was used for determination of polymerization contraction. Measurements were recorded at each 2 second for the total of 800 seconds including the periods of light application. Obtained data were analyzed statically using Repeated measures ANOVA, One way ANOVA, and Tukey test. The results of present study can be summarized as follows: 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05). 2. Contraction stress was not revealed significant difference between Halogen curing light groups and LED and Plasma Light curing with soft-start group (P>0.05). 3. LED and Plasma Light curing with soft-start showed lower contraction stress than the one-step continuous light curing (P<0.05).

  • PDF

EFFECT OF SOFT-START LIGHT CURING ON THE POLYMERIZATION AND THE CONTRACTION STRESS OF COMPOSITE RESIN (완속기시(Soft-start) 광조사 방식이 복합레진의 중합 및 수축응력에 미치는 효과)

  • Wee, You-Min;Oh, You-Hyang;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.332-343
    • /
    • 2005
  • The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at $400\;mw/cm^2$, plasma arc light curing for 6 seconds at $1300\;mW/cm^2$ and LED light curing for 10 seconds at $7The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at . For the soft-start curing method ; 2 seconds light exposure at $650\;mW/cm^2$ followed by 3 seconds at $1300\;mW/cm^2$ and exponential increase with 5 seconds followed by 10 seconds at $700\;mW/cm^2$ were used. Contraction stress was measured using strain gauge method and Vickers hardness was measured 24 hours after polymerization at the top and bottom of specimens. Resin-acrylic interfaces were observed using a scanning electron microscope(SEM). The results of present study can be summarized as follows: 1. Contraction stresses at 10 min after polymerization were significantly reduced with the soft-start curing both in plasma and LED light sources(P<0.05). 2. Plasma light curing with soft-start resulted in not only the lowest contraction stress, but also the lowest hardness(P<0.05) 3. LED light curing with soft-start showed lower contraction stress than the one-step continuous halogen and LED light curing(P<0.05). 4. Microhardness of specimens cured by LED light with soft-start was equivalent to that of cured by the one-step continuous halogen and LED light(P>0.05). 5. Curing by LED light with soft-start and conventional halogen light resulted in better marginal sealing than plasma light and one-step LED light curing.

  • PDF

Effects of hand vibration on involuntary muscle contraction

  • 박희석
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1994.04a
    • /
    • pp.394-398
    • /
    • 1994
  • The aim of the present study was to determine the influence of vibration frequency and muscle contraction level at constant vibration displacement amplitudes on a commonly observed motor response elicited by local vibratory stimulation, i.e., the Tonic Vibration Reflex (TVR). Vibration was applied to the distal tendons of the hand flexor muscles. Changes in activity of the hand flexor and extensor muscles were analyzed as a function of the vibration frequency (40-200 Hz), displacement amplitude(200.mu.m and 300.mu.m peak-to-peak), and the initial contraction level of the flexor muscles (0%, 10%, and 20% of the maximal voluntary contraction: MVC). The main results indicate that the TVR increases with vibration frequency up to 100-150 Hz and decreases beyond, and the TVR attains its maximum at 10% MVC. It appears that high frequency vibration tends to induce less muscle/tendon stress. Such a result is of particular importance for the design of handheld vibrating tools.

FINITE ELEMENT STRESS ANALYSIS OF CLASS V COMPOSITE RESIN RESTORATION SUBJECTED TO CAVITY FORMS AND PLACEMENT METHODS (와동 형태와 충전 방법에 따른 Class V 복합 레진 수복치의 유한요소법적 응력 분석)

  • Son, Yoon-Hee;Cho, Byeong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.91-108
    • /
    • 2000
  • Most of cervical abrasion and erosion lesions show gingival margin where the cavosurface angle is on cementum or dentin. Composite resin restoration of cervical lesion shrink toward enamel margin due to polymerization contraction. This shrinkage has clinical problem such as microleakage and secondary caries. Several methods to diminish contraction stress of composite resin restoration, such as modifying cavity form and building up restorations in several increments have been attempted. The purpose of this study was to compare polymerization contraction stress of composite resin in Class V cavity subjected to cavity forms and placement methods. In this study, finite element model of 5 types of Class V cavity was developed on computer tomogram of maxillary central incisor. The types are : 1) Box cavity 2) Box cavity with incisal bevel 3) V shape cavity 4) V shape cavity with incisal bevel 5) Saucer shape cavity. The placement methods are 1) Incisal first oblique incremental curing 2) Bulk curing. An FEM based program for light activated polymerization is not available. For simulation of curing dynamics, time dependent transient thermal conduction analysis was conducted on each cavity and each placement method. For simulation of polymerization shrinkage, thermal stress analysis was performed with each cavity and each placement method. The time-temperature dependent volume shrinkage rate, elastic modulus, and Poisson's ratio were determined in thermal conduction data. The results were as follows : 1. With all five Class V cavifies, the highest Von Mises stress at the composite-tooth interface occurred at gingival margin. 2. With box cavity, V shape cavity and saucer cavity, Von Mises stress at gingival margin of V shape cavity was lower than the others. And that of box cavity was lower than that of saucer cavity. 3. Preparing bevel at incisal cavosurface margin decreased the rate of stress development in early polymerization stage. 4. Preparing bevel at incisal cavosurface margin of V shape cavity increased the Von Mises stress at gingival margin, but decreased at incisal margin. 5. At incisal margin, stress development by bulk curing method was rapid at early stage. Stress development by first increment of incremental curing method was also rapid but lower than that by bulk curing method, however after second increment curing final stress was the same for two placement methods. 6. At gingival margin, stress development by incremental curing method was suddenly rapid at early stage of second increment curing, but final stress was the same for two placement methods.

  • PDF

Study on the Physical Characteristics of Water Supply Steel Pipe according to Temperature Change (수도용 강관의 온도변화에 따른 물리적 특성에 대한 연구)

  • Kim, Woo-young;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.733-740
    • /
    • 2017
  • 'The facilities standards of water supply' issued by the Ministry of Environment in 2004 indicates that expansion joints cannot be used in welding water supply steel pipes. However, their reason is not clear and it is difficult to confirm the stability of the steel pipe for a water supply pipeline. The purpose of this study is to determine whether or not an expansion joint is necessary to improve the stability of water supply in steel pipe through a displacement analysis of the pipework. The test results are as follows. Firstly, it was found that expansion and contraction of the water supply steel pipe (D 2,400 mm) occur repeatedly in 4 cycles per year, and the maximum expansion and contraction amount of the pipe is 13.03 mm in 1.24 km pipelines. Secondly, the thermal stress caused by expansion and contraction of the steel pipe is $13.7{\sim}36.1kgf/cm^2$ according to the burial depth (0~4 m). The main comparison factors to determine the stability of the steel pipe (STWW 400) were the allowable tensile strength and the fatigue limit, which were computed to be $4,100kgf/cm^2$ and $1,840kgf/cm^2$, respectively. Finally, the thermal stress of the steel pipe is very small compared to the allowable tensile stress and fatigue stress. Therefore, thermal stress does not affect the stability of the steel pipe, although the expansion and contraction of the steel pipe occurs by temperature changes. In conclusion, the study demonstrated that expansion joints are not required in water supply steel pipelines.

Numerical result of complex quick time behavior of viscoelastic fluids in flow domains with traction boundaries

  • Kwon, Young-Don
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.4
    • /
    • pp.211-219
    • /
    • 2007
  • Here we demonstrate complex transient behavior of viscoelastic liquid described numerically with the Leonov model in straight and contraction channel flow domains. Finite element and implicit Euler time integration methods are employed for spatial discretization and time marching. In order to stabilize the computational procedure, the tensor-logarithmic formulation of the constitutive equation with SUPG and DEVSS algorithms is implemented. For completeness of numerical formulation, the so called traction boundaries are assigned for flow inlet and outlet boundaries. At the inlet, finite traction force in the flow direction with stress free condition is allocated whereas the traction free boundary is assigned at the outlet. The numerical result has illustrated severe forward-backward fluctuations of overall flow rate in inertial straight channel flow ultimately followed by steady state of forward flow. When the flow reversal occurs, the flow patterns exhibit quite complicated time variation of streamlines. In the inertialess flow, it takes much more time to reach the steady state in the contraction flow than in the straight pipe flow. Even in the inertialess case during startup contraction flow, quite distinctly altering flow patterns with the lapse of time have been observed such as appearing and vanishing of lip vortices, coexistence of multiple vortices at the contraction comer and their merging into one.